ISO 9001:2015 certified industrial automation spare parts supplier

SIGNAL INTERFACES & INDUSTRIAL COMMUNICATION

I/O & Communication Modules

Browse input/output modules, communication interfaces and related system components. Confirm the complete part number, signal type, connection arrangement and installed platform before selecting a replacement or additional module.

Send your complete part numbers, quantities and required delivery date for pricing, availability and estimated dispatch. You can combine multiple items in one enquiry.

Industrial input and output modules
  • Yokogawa ADV551-P60 front connector view
    Yokogawa ADV551-P60 32-Channel 24V DC Digital Output Module
    Yokogawa ADV551-P60 is a 32-channel current-sink transistor output module for CENTUM FIO. It supports status, pulse-width and time-proportioning output patterns with output-status display. Version check: Match -P60, sink-output load and configured point-mode pattern; check paired-channel and redundancy restrictions before replacement.
    Read More
  • Yokogawa ADV151-P60 front connector view
    Yokogawa ADV151-P60 32-Channel 24V DC Digital Input Module
    Yokogawa ADV151-P60 is a 32-channel 24 V DC digital input module for CENTUM FIO. The P version supports pushbutton input, and suffix 6 provides input-status display without explosion protection. Version check: Confirm -P60 pushbutton capability, status display, hardware Style and input polarity; do not substitute an output or SOE-capture version.
    Read More
  • Yokogawa AAP135-S50 front connector view
    Yokogawa AAP135-S50 8-Channel Isolated Pulse Input Module
    Yokogawa AAP135-S50 is an eight-channel isolated pulse input module for CENTUM FIO. It accepts contact, voltage-pulse and current-pulse signals, with frequency limits determined by the selected signal and redundancy configuration. Version check: Match pulse source, frequency, transmitter supply and redundancy mode; dry-contact limits are lower than the 10 kHz electronic-pulse limit.
    Read More
  • Yokogawa AAI841-H00 analog I/O module
    Yokogawa AAI841-H00 8-Input 8-Output HART Analog I/O Module
    Yokogawa AAI841-H00 is a non-isolated FIO module with eight 4–20 mA inputs and eight 4–20 mA outputs. It supports up to eight loops, HART communication and dual-redundant configurations. Version check: Confirm the legacy -H00 code, hardware Style, node and terminal option; HART in an ER-bus remote node requires EB401 Rev. 2 or later.
    Read More
  • Yokogawa AAI543-H50 front connector view
    Yokogawa AAI543-H50 16-Channel HART Analog Output Module
    Yokogawa AAI543-H50 is a 16-channel isolated 4–20 mA output module for CENTUM FIO. It supports HART communication and standard-response switching in a dual-redundant configuration. Version check: Match the -H50 standard switchover response, hardware Style and terminal option; a redundant pair must use the same response class.
    Read More
  • Yokogawa AAI143-H50 front connector view
    Yokogawa AAI143-H50 16-Channel HART Analog Input Module
    Yokogawa AAI143-H50 is a 16-channel isolated 4–20 mA input module for CENTUM FIO. It supports HART communication, per-channel two-wire or four-wire transmitter selection and dual-redundant configurations. Version check: Confirm -H50, hardware Style, two-wire/four-wire channel settings and the existing single or dual terminal adapter.
    Read More
  • Yokogawa AAI135-H50 HART input module
    Yokogawa AAI135-H50 8-Channel HART Analog Input Module
    Yokogawa AAI135-H50 is an eight-channel, channel-isolated 4–20 mA input module for CENTUM FIO systems. It combines process-current acquisition with HART communication and supports dual-redundant module configurations. Version check: Confirm -H50, channel isolation, hardware Style and the installed terminal adapter; -S versions do not provide HART.
    Read More
  • T9882 termination front view
    ICS Triplex T9882 AADvance Dual Analog Output Termination Assembly
    ICS Triplex T9882 is an AADvance dual analog output termination assembly. It provides eight field-output connections and supports two compatible analog output modules for a redundant output arrangement. Version check: Confirm T9882 dual analog-output termination, the matched T9481/T9482 module arrangement, coding pegs and field-loop polarity before replacement.
    Read More
  • T9832 termination front view
    ICS Triplex T9832 AADvance Dual Analog Input Termination Assembly
    ICS Triplex T9832 is an AADvance dual analog input termination assembly. It provides sixteen field-input connections and the termination interface for two compatible analog input modules in a redundant arrangement. Version check: Confirm T9832 dual analog-input termination, matched T9431 or T9432 module types, coding pegs and the existing field-loop fuse arrangement.
    Read More
  • T8461C module front view
    ICS Triplex T8461C Trusted TMR 24/48V DC Digital Output Module
    ICS Triplex T8461C is a coated Trusted TMR digital output module for 24/48 V DC loads. Its forty outputs are arranged in five power groups, with output-state, voltage, current and line-fault diagnostics. Version check: Match T8461C revision, 24/48 V field supply, per-channel load and FTA/cable keying; retain the configured fail-safe output states.
    Read More
  • T8442C module front view
    ICS Triplex T8442C Trusted TMR Speed Monitor Module
    ICS Triplex T8442C is a coated Trusted TMR speed monitor for rotating machinery. It supports three machine groups and provides overspeed and over-acceleration protection using the matching speed-input and shutdown-output termination assemblies. Version check: Confirm T8442C revision, probe type, gear-tooth count, trip settings and the T8846/T8891 termination arrangement before replacement.
    Read More
  • T8431C module front view
    ICS Triplex T8431C Trusted TMR 40-Channel Analog Input Module
    ICS Triplex T8431C is a coated Trusted TMR analog input module for forty process signals. It is typically used with 4–20 mA field loops and reports channel values, line faults and module diagnostics. Version check: Match T8431C hardware, firmware and FTA; for Series C units dated T2108 or later, check product notice 2025-08-002 and the applicable firmware correction.
    Read More
  • T8403 module front view
    ICS Triplex T8403 Trusted TMR 24V DC Digital Input Module
    ICS Triplex T8403 is a Trusted TMR digital input module for forty nominal 24 V DC field inputs. It provides input-state, line-fault and module diagnostic information to the Trusted system. Version check: Match T8403 hardware/software revision, field termination and cable keying; T8403C is the official replacement and still requires system compatibility review.
    Read More
  • T8314C fibre unit front view
    ICS Triplex T8314C Trusted Fibre TX/RX Unit
    ICS Triplex T8314C is a coated Trusted fibre transmitter/receiver unit. It converts copper Expander Bus signals to single-mode fibre for a remote Trusted expansion link of up to 10 km, subject to the link timing requirements. Version check: Confirm T8314C coating, six-unit link arrangement, single-mode SC fibre, cable pairing and the remote Expander Bus timing budget.
    Read More
  • T3411F module front view
    ICS Triplex T3411F Regent Type F Monitored Digital Input Module
    ICS Triplex T3411F is a 16-channel Regent Type F monitored digital input module. Its externally powered 24/48 V DC field circuits support switch-state monitoring and line-fault detection with the appropriate monitoring network. Version check: Confirm the full T3411F suffix, external field-supply voltage, monitoring network and upper 9/lower 7 slot keys before replacement.
    Read More
  • T3411 module front view
    ICS Triplex T3411 Regent 16-Channel Monitored Digital Input Module
    ICS Triplex T3411 is a Regent 16-channel monitored digital input module for 24 V DC field-switch signals. It supports input-line fault detection when the correct monitoring devices and application logic are used. Version check: Confirm T3411 versus externally powered T3411F, the slot key positions and the installed field-switch monitoring arrangement.
    Read More
  • 1746-OW16 front terminal view
    Allen-Bradley 1746-OW16 SLC 500 Relay Output Module
    Allen-Bradley 1746-OW16 is a 16-point SLC 500 relay output module for switching AC or DC field circuits. Its outputs are arranged in two groups of eight, with operating ranges of 5–265V AC or 5–125V DC. Version check: Confirm 1746-OW16, both eight-point common groups and the actual AC/DC load make, break and continuous ratings. Relay outputs are not transistor outputs.
    Read More
  • 1746-OB16E front terminal view
    Allen-Bradley 1746-OB16E SLC 500 Protected DC Output Module
    Allen-Bradley 1746-OB16E is a 16-point SLC 500 sourcing DC output module with electronic short-circuit and overload protection. It switches 10–30V DC field loads and provides an E-FUSE indicator for an overloaded output channel. Version check: Confirm 1746-OB16E, hardware series, 10–30V DC sourcing loads and the protection auto-reset behavior. It is not the 10–50V 1746-OB16.
    Read More
  • 1756-DMD30 front SD3000 interface
    Allen-Bradley 1756-DMD30 ControlLogix SD3000 Drive Interface Module
    Allen-Bradley 1756-DMD30 is a ControlLogix drive interface module for SD3000 DC drive systems. It connects an individual PMI chassis through fiber-optic Drive Communication and supports SynchLink synchronization. Version check: Match the SD3000 drive type, installed module firmware and project electronic keying. The 1756-DMF30 serves SF3000 field supplies and is not the same interface.
    Read More
  • 1756-OF8I front label side
    Allen-Bradley 1756-OF8I ControlLogix Isolated Analog Output Module
    Allen-Bradley 1756-OF8I is a ControlLogix eight-channel isolated analog output module. Each channel can provide a voltage or current output for driving analog field devices with channel-to-channel isolation. Version check: Confirm 1756-OF8I, channel output type, load resistance and RTB wiring. Review engineering-unit scaling and clamp limits before replacement.
    Read More

Request a quote

Have a part number?
Let us check it.

Send the exact model and quantity, plus a nameplate photo or parts list if available.

Dedicated RFQ contact
Sandy Lin Sales & General Manager

Send the complete model and quantity for review.

What happens next

  1. Email confirmation
  2. Requirement review
  3. Written quotation

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message