1746-OA8
SLC 500 8-point AC output module
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier



Allen-Bradley 1746-OW16 is a 16-point SLC 500 relay output module for switching AC or DC field circuits. Its outputs are arranged in two groups of eight, with operating ranges of 5–265V AC or 5–125V DC.
Version check: Confirm 1746-OW16, both eight-point common groups and the actual AC/DC load make, break and continuous ratings. Relay outputs are not transistor outputs.
Lifecycle status: Discontinued
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Allen-Bradley 1746-OW16 is a 16-point relay output module for SLC 500 systems, translating processor commands into contact switching for AC or DC field circuits within the relay ratings. Its outputs are arranged in two groups of eight, with a shared common for each group, allowing the application to control multiple on/off loads through relay contacts. This operating principle makes 1746-OW16 relevant where the existing equipment requires contact outputs rather than sourcing or sinking transistor signals. The relay load rating, group arrangement and switching duty must match the application when the module is selected as a replacement.
Hardware specifications. The 1746-OW16 has two groups of eight outputs with separate commons. Its operating range is 5–265V AC or 5–125V DC, with a maximum resistive-load ON and OFF delay of 10ms. Backplane demand is 170mA at 5V DC and 180mA at 24V DC, and field wiring uses a removable terminal block.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer | Allen-Bradley |
| Catalog number | 1746-OW16 |
| Product type | SLC 500 AC/DC relay output module |
Functional Configuration |
|
| Output points | 16; two groups of 8 points per common |
| Terminal connection | Removable terminal block |
Performance & Power |
|
| Field operating voltage | 5–265V AC or 5–125V DC |
| Maximum resistive-load signal delay | 10ms ON; 10ms OFF |
| Backplane current | 170mA at 5V DC; 180mA at 24V DC |
| Maximum off-state leakage | 0mA |
| Minimum load current | 10mA at 5V DC |
| Module/common current limits | 16A AC per module; 8A per common; each contact must also meet its voltage-dependent make/break and continuous rating |
Environment |
|
| Operating temperature | 0–60°C |
| Operating humidity | 5–95%, noncondensing |
System and application compatibility. The 1746-OW16 belongs to the SLC 500 digital I/O family. Match the existing output grouping and the voltage, make/break and continuous-current requirements of each load. The sixteen-point count alone does not make a DC transistor module equivalent, and the 8A-per-common limit does not represent a per-contact rating.
Check the AC/DC contact load and both output-common groups before wiring the relay module.
| Connection | Use | Check |
|---|---|---|
| VAC-VDC 1 | Common for the first eight outputs | Match field-circuit voltage and common-group load. |
| VAC-VDC 2 | Common for the second eight outputs | Preserve the separate eight-point grouping. |
| OUT 0–15 | Relay contact outputs | Use each contact’s make, break and continuous ratings; group ratings are not point ratings. |
Disconnect chassis power and safely isolate the AC/DC field circuits before handling or wiring the module.
Align with the SLC chassis card guides and slide in until the self-locking tabs engage. The first slot is reserved for the processor or 1747-ASB.
Follow the 1746-OW16 terminal diagram. Maximum conductor size is 2mm² (14AWG), with no more than two wires per terminal and maximum terminal torque of 0.9N·m; secure wires and inspect before energizing.
Never install, remove or wire modules with chassis power applied. Observe electrostatic-discharge and hazardous-location requirements.
Use suitable suppression across external inductive loads to extend relay-contact life. Verify actual load make/break and continuous-current ratings as well as module/common limits.
Some chemicals can degrade relay epoxy sealing. Inspect for deterioration and replace the module if degradation is found.
It has 16 relay contact outputs. It is not a sourcing or sinking transistor-output module, so verify the field circuit and load rating when comparing replacements.
Its relay-output operating ranges are 5–265V AC and 5–125V DC. Verify the voltage-dependent make, break and continuous-current limits for each actual load, and preserve the correct common grouping.
No. The 16 outputs are arranged in two groups of eight points per common. Do not treat the shared-common outputs as sixteen independent isolated circuits.
No. The 8A value is a common-group limit, not a per-contact rating. The module limit is 16A AC, and each contact must also satisfy the applicable make, break and continuous-current ratings for its voltage and load.
Allow 170mA from the 5V DC backplane supply and 180mA from the 24V DC backplane supply. Include both values when checking the loaded chassis power budget.
No. Disconnect chassis power before installing, removing or wiring the module. Isolate field-circuit power as required and observe the hazardous-location and electrostatic-discharge precautions.
Inspect the relay sealing materials for degradation and replace the module if deterioration is found. Some chemicals can degrade the relay epoxy and its sealing properties.
At 240 V AC the rating per contact is 7.5 A when closing and 0.75 A when opening. The continuous rating is 2.5 A per contact, subject to the common and module limits.
Product photograph, module selection notes and selected Rockwell Automation installation information.
PDF · 3 pages · 50.1 KB · Compiled by EWOLO CONTROL. 1746-IN027D-EN-P D
Preview Product Reference (PDF)SLC 500 8-point AC output module
SLC 500 16-point AC output module
SLC 500 12-point AC output module
SLC 500 8-point sourcing DC output module
SLC 500 16-point sourcing DC output module
SLC 500 16-point protected DC output module
SLC 500 6-point isolated DC output module
SLC 500 8-point sourcing DC output module
SLC 500 16-point sourcing DC output module
SLC 500 8-point sinking DC output module
SLC 500 16-point sinking DC output module
SLC 500 16-point sinking DC output module
SLC 500 4-point relay output module
SLC 500 8-point relay output module
SLC 500 8-point isolated relay output module
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Bently Nevada 140471-01 is the internal-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, internal terminations and 3500/42M configuration before replacing 140471-01.
Bently Nevada 140482-01 is the external-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, external terminations and 3500/42M configuration before replacing 140482-01.
Bently Nevada 149992-01 is the standard 16-channel relay output module used in the 3500/33 machinery-protection relay assembly. It provides the rear-rack switching interface for relay actions configured from the 3500 system's monitoring information. Version check: Confirm standard relay contacts, the minimum load, 149986-01 control module and required energized/de-energized logic before replacing 149992-01.
ProSoft Technology MVI56-DFCM connects a ControlLogix controller to DF1 serial devices through two independently configurable communication ports. Version check: Match the MVI56-DFCM application, DF1 device addressing and port modes; the reduced-data-block MVI56-DFCMR uses a different backplane transfer arrangement.
ProSoft Technology MVI56-DFCMR is a DF1 interface module for ControlLogix applications that use reduced backplane data transfers, including remote racks connected over ControlNet or Ethernet. Version check: Retain the MVI56-DFCMR reduced-block controller data structures and transfer logic; match each port’s DF1 mode, device address and file mapping.
ProSoft Technology MVI56-MCM adds two independent Modbus serial interfaces to a ControlLogix system. Version check: Preserve the MVI56-MCM controller project, register map and serial settings; migration to an enhanced MVI56E variant requires its applicable migration procedure.
ProSoft Technology MVI69-MNETC connects a 1769-based controller application to multiple Modbus TCP/IP server devices. Version check: Match MVI69-MNETC client-only operation, the 1769 controller program and power-supply distance; retain the installed firmware’s supported Ethernet options.
ProSoft Technology PLX31-EIP-MBS4 bridges EtherNet/IP controller data and four independent Modbus serial networks. Version check: Match the four-port PLX31-EIP-MBS4, serial interface modes, I/O connection sizes and installed firmware; retain the matching ProSoft Configuration Builder configuration.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :