Allen-Bradley 1746-OB16E SLC 500 Protected DC Output Module

Allen-Bradley 1746-OB16E is a 16-point SLC 500 sourcing DC output module with electronic short-circuit and overload protection. It switches 10–30V DC field loads and provides an E-FUSE indicator for an overloaded output channel.

Version check: Confirm 1746-OB16E, hardware series, 10–30V DC sourcing loads and the protection auto-reset behavior. It is not the 10–50V 1746-OB16.

Download
  • Allen-Bradley 1746-OB16E SLC 500 Protected DC Output Module

    Allen-Bradley 1746-OB16E is a 16-point, electronically protected sourcing DC output module for the SLC 500 platform. It converts processor output commands into switched DC signals for connected field loads, with each point following the state commanded by the application. Electronic protection limits current on an overloaded or short-circuited channel, while unaffected channels continue to follow the processor commands. This protection distinguishes 1746-OB16E from standard transistor output options, but it does not protect against reverse-polarity or AC supply errors and does not replace appropriate external circuit protection. The module is intended for compatible DC loads within its channel and module ratings.

    Hardware specifications. The 1746-OB16E operates with 10–30V DC field power and has 16 output points on one common. Each point supports 1.0A at 30°C or 0.50A at 60°C, subject to the 8.0A module limit. Backplane demand is 135mA at 5V DC and 0mA at 24V DC; the module has a removable terminal block.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer Allen-Bradley
    Catalog number 1746-OB16E
    Product type SLC 500 electronically protected sourcing DC output module

    Functional Configuration

    Output points 16; 16 points per common
    Protection behavior Thermal current limiting with automatic reset; E-FUSE LED
    Programming ID code 2920
    Terminal connection Removable terminal block

    Performance & Power

    Field operating voltage 10–30V DC, sourcing
    Continuous current per point 1.0A at 30°C; 0.50A at 60°C
    Maximum continuous module current 8.0A at 0–60°C; also observe each-point limit
    Backplane current 135mA at 5V DC; 0mA at 24V DC
    Maximum resistive-load delay 1.0ms ON; 1.0ms OFF
    Maximum off-state leakage 1mA
    Minimum load current 1mA
    Maximum on-state voltage drop 1.0V at 0.50A

    Environment

    Operating temperature 0–60°C

    Compatibility & Selection Guide

    System and configuration compatibility. Configure the 1746-OB16E in the SLC 500 system using module ID code 2920. Series B and later provide fast turn-off behavior for inductive loads; verify the installed hardware series and existing output application before replacement. The electronic protection automatically resets after cooling and does not replace required circuit protection.

    Wiring & Installation Reference

    Match the 10–30V DC sourcing circuit and every load limit before connecting the removable terminal block.

    Signal and terminal selection

    Connection Use Check
    VDC / DC COM External DC supply and return Use 10–30V DC; do not reverse polarity or connect AC.
    OUT 0–15 Sixteen sourcing output points Observe per-point temperature derating and the 8A module total.
    E-FUSE indicator Overload/short-circuit indication Auto-reset can restore commanded output after cooling.

    View terminal diagram (PDF)

    Installation checks

    1. Isolate power

      Remove chassis power and safely isolate field loads before insertion, removal or wiring.

    2. Seat and secure the module

      Align the board with the SLC chassis guide and slide it in until the retaining tabs lock. The first chassis slot is reserved for the processor or 1747-ASB.

    3. Wire and verify protection

      Use the exact terminal diagram; maximum 2mm² (14AWG), two wires per terminal and 0.9N·m terminal torque. Secure cables, confirm ID2920 and check safe output behavior before restoring power.

    View installation guide

    Power and handling precautions

    • Electronic protection does not protect reverse polarity or AC wiring and does not replace code-required fuses/circuit breakers. Account for thermal auto-reset under an unresolved overload.

    • A transient output pulse can occur when external DC power reaches the common terminals, even if the processor is unpowered. Assess loads for inadvertent operation.

    • Use a suitable industrial enclosure and electrostatic-discharge protection. Never install, remove or wire modules with chassis power applied.

    Frequently Asked Questions

    Is the 1746-OB16E a sourcing or sinking output module?

    It is a sourcing DC output module. Use 10–30V DC field power and a compatible load return; a sinking-output module has a different circuit arrangement.

    Can the 1746-OB16E replace a 1746-OB16 without checking the load?

    No. The protected 1746-OB16E operates at 10–30V DC, while the 1746-OB16 range extends to 50V DC. Compare load voltage, per-point and module current, hardware series and protection behavior before replacement.

    Does the 1746-OB16E electronic protection replace external fuses?

    No. It limits overload or short-circuit current after thermal cut-out. It does not protect against reverse polarity or AC wiring and does not replace fuses, circuit breakers or other code-required wiring protection.

    What happens when one 1746-OB16E output overloads?

    The affected channel limits current after reaching its thermal cut-out temperature; the other channels continue following the processor. The channel can automatically reset after cooling and resume the commanded output, so correct the fault and account for automatic restart.

    Can all 1746-OB16E outputs carry 1A continuously?

    No. A point is rated 1.0A at 30°C or 0.50A at 60°C, and the entire module is limited to 8.0A. Apply both the point and total-module limits.

    Which ID code is used to configure the 1746-OB16E?

    Use ID code 2920 in the programming software or hand-held terminal. Verify that the configured module identity matches the installed protected-output module.

    Can the 1746-OB16E be replaced with chassis power on?

    No. Disconnect chassis power before installing, removing or wiring the module. Also isolate field power, observe hazardous-location precautions and protect the electronics from electrostatic discharge.

    How much short-duration inrush can the 1746-OB16E tolerate?

    The 10 ms surge ratings are 2 A per output and 32 A for the module. The rated repetition is once per second at 30 °C and once every two seconds at 60 °C.

    Manufacturer Documentation

    1746-OB16E Product Reference

    Product photograph, module selection notes and selected Rockwell Automation installation information.

    PDF · 3 pages · 52.5 KB · Compiled by EWOLO CONTROL. 1746-IN027D-EN-P D

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Allen-Bradley 1746-OB16E

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.