ProSoft Technology MVI56-DFCM connects a ControlLogix controller to DF1 serial devices through two independently configurable communication ports.
Version check: Match the MVI56-DFCM application, DF1 device addressing and port modes; the reduced-data-block MVI56-DFCMR uses a different backplane transfer arrangement.
Lifecycle status: Phase-out
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
The MVI56 DF1 Master/Slave Communication Module is a ControlLogix backplane compatible module that allows Allen-Bradley ControlLogix I/O compatible processors to interface easily with DF1 protocol compatible devices and hosts. Devices commonly supporting the protocol include Rockwell Automation PLCs and power monitoring equipment, as well as several other third party devices in the marketplace.
Hardware specifications. The module has two serial ports supporting the DF1 protocol, with each port user-configurable to act as a master or as a slave. Data transfer between the module and the ControlLogix processor is asynchronous to the DF1 network, with the module's internal database being used to exchange data between the processor and the DF1 network.
System compatibility. The module is recognized as an Input/Output module and has access to processor memory for data transfer between processor and module. Ladder Logic is used for data transfer between module and processor. Configuration data obtained through user-defined ladder. Sample ladder file included
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer | ProSoft Technology |
| Model | MVI56-DFCM |
| General Specifications | Single Slot – 1756 backplane compatible Local or remote rack |
| Shipped with Unit | RJ45 to DB-9M cables for each port 6-foot RS-232 configuration cable |
Functional Configuration |
|
| LED Indicators: | Module Status Backplane Transfer Status Application Status Serial Activity |
| CFG Port (CFG) | RJ45 (DB-9M with supplied cable) RS-232 only |
| Application ports (PRT1 & PRT2) | Full hardware handshaking control, providing radio, modem and Multidrop support |
| Software configurable communication parameters | Baud rate: 110 to 115,200 baud, depending on protocol RS-232, 485 and 422 Parity: none, odd or even Data bits: 5, 6, 7, or 8 Stop bits: 1 or 2 RTS on/off delay: 0 to 65535 ms |
| App Ports (P1,P2) (Serial modules) | RJ45 (DB-9M with supplied cable) RS-232 handshaking configurable 500V Optical isolation from backplane |
Performance & Power |
|
| Backplane Current Load | 800 mA @ 5 V |
| Internal data | 5,000 words |
| Master command list | Up to 100 commands per port |
Environment |
|
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Storage Temperature | –40 to 85°C (–40 to 185°F) |
| Shock: | 30g Operational 50g non-operational Vibration: 5 g from 10 to 150 Hz |
| Relative Humidity | 5 to 95% (non-condensing) |
ControlLogix chassis. MVI56-DFCM occupies one slot in a 1756 ControlLogix chassis. A local or remote chassis can host the module. The ControlLogix application exchanges data with the module through ladder logic and its internal database.
DF1 port selection. The two application ports can be assigned independently as a DF1 master or slave. Match each port's serial interface and DF1 mode to its connected equipment. The separate configuration port uses RS-232.
MVI56-DFCM mounting and connection reference.
Application ports: Set the hardware jumpers for the required RS-232, RS-422 or RS-485 interface before connecting P1/P2.
Configuration port: Use the separate RS-232 configuration/debug connection; it is not an Ethernet port.
Turn off chassis power before installation.
Align the upper and lower guides and slide the module into the ControlLogix rack until the backplane connector is engaged.
Engage both retaining clips and use the actual slot number in the controller project.
Remove power or confirm a non-hazardous location before disconnecting equipment. Energized removal can cause an electrical arc.
Use the applicable serial pinout and interface jumpers; RJ45 connector shape alone does not define the interface.
Issue warm-boot block 9998. This restarts the module software and reloads configuration from the ControlLogix processor. Cold-boot block 9999 performs a hardware reset instead.
Use event-command block 1000 for port 1 or 2000 for port 2. A return value of 1 in read-block word 2 means the command was added to the queue; 0 means it was rejected. Each port has a 100-command queue, and an invalid command or full queue causes rejection.
One to six command-list entries can be triggered. Blocks 5001–5006 address port 1 and 5101–5106 address port 2. Each supplied command index is 0–99, and queued requests take priority over normal polling.
Slave status 2 marks a failed device temporarily suspended by the error-delay mechanism. ErrorDelayCntr counts skipped command scans. Polling resumes when the counter reaches zero; status 3 indicates a slave disabled through ladder logic.
Yes. Each port supports an override file map with up to 50 entries. It maps DF1 file identifiers to selected internal database locations; configuration blocks 7000 and 7100 transfer the maps for ports 1 and 2 respectively.
In the module configuration error word, 0x0008 identifies a read-data range outside the database and 0x0080 identifies a write-data range outside it. In a port configuration error word, 0x0008 instead identifies an invalid baud-rate value.
The DFCM.STATUS structure receives module status with read-block transfers. Per-port counters include requests, responses and communication errors, allowing the application to track successful transactions and fault activity independently for each serial port.
Yes. Special block 9972 sets the module time, and block 9973 reads it. These clock operations use dedicated backplane blocks rather than normal DF1 polling commands.
Product photograph and technical summary, followed by selected manufacturer pages covering mounting and connections.
PDF · 4 pages · 100.9 KB · Compiled by EWOLO CONTROL. December 3, 2020. Selected manufacturer pages retained.
Preview Product Reference (PDF)C-programmable Ethernet application module
Liquid and gas flow computer
Ethernet Global Data communication module
Generic ASCII Ethernet communication module
Generic serial ASCII interface module
CM4 gas analyzer master module
Enhanced ASCII serial communication module
Logix-XT Modbus TCP/IP communication module
C-programmable serial application module
C-programmable Ethernet application module
Enhanced Modbus TCP/IP communication module
Modbus serial lite communication module
EtherNet/IP to Modbus serial gateway
Dual-Ethernet EtherNet/IP to Modbus TCP gateway
DF1 routing module
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Bently Nevada 140471-01 is the internal-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, internal terminations and 3500/42M configuration before replacing 140471-01.
Bently Nevada 140482-01 is the external-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, external terminations and 3500/42M configuration before replacing 140482-01.
Bently Nevada 149992-01 is the standard 16-channel relay output module used in the 3500/33 machinery-protection relay assembly. It provides the rear-rack switching interface for relay actions configured from the 3500 system's monitoring information. Version check: Confirm standard relay contacts, the minimum load, 149986-01 control module and required energized/de-energized logic before replacing 149992-01.
ProSoft Technology MVI56-DFCM connects a ControlLogix controller to DF1 serial devices through two independently configurable communication ports. Version check: Match the MVI56-DFCM application, DF1 device addressing and port modes; the reduced-data-block MVI56-DFCMR uses a different backplane transfer arrangement.
ProSoft Technology MVI56-DFCMR is a DF1 interface module for ControlLogix applications that use reduced backplane data transfers, including remote racks connected over ControlNet or Ethernet. Version check: Retain the MVI56-DFCMR reduced-block controller data structures and transfer logic; match each port’s DF1 mode, device address and file mapping.
ProSoft Technology MVI56-MCM adds two independent Modbus serial interfaces to a ControlLogix system. Version check: Preserve the MVI56-MCM controller project, register map and serial settings; migration to an enhanced MVI56E variant requires its applicable migration procedure.
ProSoft Technology MVI69-MNETC connects a 1769-based controller application to multiple Modbus TCP/IP server devices. Version check: Match MVI69-MNETC client-only operation, the 1769 controller program and power-supply distance; retain the installed firmware’s supported Ethernet options.
ProSoft Technology PLX31-EIP-MBS4 bridges EtherNet/IP controller data and four independent Modbus serial networks. Version check: Match the four-port PLX31-EIP-MBS4, serial interface modes, I/O connection sizes and installed firmware; retain the matching ProSoft Configuration Builder configuration.