ProSoft MVI56-MCM Modbus Serial Communication Module

ProSoft Technology MVI56-MCM adds two independent Modbus serial interfaces to a ControlLogix system.

Version check: Preserve the MVI56-MCM controller project, register map and serial settings; migration to an enhanced MVI56E variant requires its applicable migration procedure.

Download
  • ProSoft MVI56-MCM Modbus Serial Communication Module

    ProSoft Technology MVI56-MCM adds two independent Modbus serial interfaces to a ControlLogix system. It exchanges coil and register data with Modbus instruments, controllers and supervisory systems, using either RTU or ASCII communication. Each port can operate as a master or slave, and the onboard database links serial transactions to the ControlLogix application through the 1756 backplane. The module supports cyclic polling, controller-triggered transactions and Enron/Daniel floating-point data handling for compatible devices.

    Hardware specifications. The module occupies one ControlLogix slot and provides two jumper-selected RS-232/RS-422/RS-485 ports plus a separate RS-232 configuration/debug connection. Its database holds 5,000 16-bit registers and each master port supports 100 commands. Backplane demand is 800 mA at 5 V DC plus 3 mA at 24 V DC; operating temperature is 0 to 60 °C.

    System compatibility. The ControlLogix project uses MVI56-MCM-specific user-defined data types and ladder routines for configuration, data and status exchange. Modbus master and slave modes support coil and holding/input-register transactions. Slave addressing is configurable from 1 to 247, and the two ports can use different serial modes and protocol settings.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer ProSoft Technology
    Model MVI56-MCM
    Platform ControlLogix / 1756 backplane

    Functional Configuration

    Protocol Modbus RTU / ASCII
    Port roles Master or slave, independently configured
    Application ports 2; RS-232 / RS-422 / RS-485

    Performance & Power

    Database 5,000 16-bit registers
    Command list Up to 100 per master port
    Backplane current 800 mA at 5 V DC; 3 mA at 24 V DC

    Environment

    Operating temperature 0 to +60 °C
    Storage temperature −40 to +85 °C
    Humidity 5–95%, non-condensing

    Compatibility & Selection Guide

    ControlLogix integration. MVI56-MCM uses a 1756 ControlLogix chassis and model-specific controller data types and ladder routines to exchange configuration, process data and status.

    Modbus device selection. A port can be configured independently for Modbus RTU or ASCII and as a master or slave. In slave mode the station address is configurable from 1 to 247. The connected equipment must use the same serial settings and Modbus framing.

    Wiring & Installation Reference

    MVI56-MCM mounting and connection reference.

    Serial connections

    Application ports: Set the hardware jumpers for the required RS-232, RS-422 or RS-485 interface before connecting P1/P2.

    Configuration port: Use the separate RS-232 configuration/debug connection; it is not an Ethernet port.

    View terminal diagram (PDF)

    Rack mounting

    1. Isolate power

      Turn off chassis power before installation.

    2. Insert the module

      Align the upper and lower guides and slide the module into the ControlLogix rack until the backplane connector is engaged.

    3. Secure and identify

      Engage both retaining clips and use the actual slot number in the controller project.

    View mounting diagram

    Power and handling precautions

    • Remove power or confirm a non-hazardous location before disconnecting equipment. Energized removal can cause an electrical arc.

    • Use the applicable serial pinout and interface jumpers; RJ45 connector shape alone does not define the interface.

    Frequently Asked Questions

    Why can MVI56-MCM configuration values disappear after changing a controller data type?

    Changing the user-defined data type can reset values in the MCM tag to zero. Save the configuration values before resizing the data arrays and restore them afterward. Read and write array sizes should use multiples of 200 words.

    Which MVI56-MCM swap setting corrects a two-register floating-point value?

    For a four-byte value ABCD, swap code 0 preserves ABCD, code 1 produces CDAB, code 2 produces DCBA and code 3 produces BADC. Select the order required by the connected device’s register representation.

    What address should MVI56-MCM use for six-digit Modbus register 400001?

    Use device address 0 with function 3 for holding register 400001. Input register 300001 likewise uses address 0 with function 4. The register prefix is represented by the function code, not included in the zero-based device address.

    How much MVI56-MCM database space is needed for seven Enron floating-point values?

    Reserve 14 internal 16-bit registers. Enron addressing treats each remote floating-point address as one 32-bit value, but each value still occupies two 16-bit words in the module database.

    When should MVI56-MCM Command Control be used instead of Event Command?

    Command Control executes an existing command-list entry on demand and retains its normal CmdErrPtr error reporting. Event Command builds a transaction outside the regular list and does not report that transaction through CmdErrPtr. Frequent event traffic can delay normal polling.

    Why can MVI56-MCM return Modbus exception 6 during pass-through writes?

    Exception 6 indicates that the module is busy processing the preceding pass-through write. The ControlLogix ladder handshake must complete that write before another is accepted. The application must also maintain the corresponding write-data values.

    How does MVI56-MCM prevent one offline slave from delaying every poll?

    ErrorDelayCounter temporarily skips the failed slave for the configured number of polling attempts. ResponseTimeout and RetryCount first determine how long each failed transaction is attempted; the delay counter then reduces repeated attempts to that slave.

    Why are MVI56-MCM command error codes missing from the PLC read data?

    CmdErrPtr must point to a database range included in the module’s ReadData transfer area. Allocate one error word per configured command and keep that range separate from process data and other status blocks.

    Manufacturer Documentation

    MVI56-MCM Product Reference

    Product photograph and technical summary, followed by selected manufacturer pages covering mounting and connections.

    PDF · 4 pages · 97.0 KB · Compiled by EWOLO CONTROL. February 11, 2011. Selected manufacturer pages retained.

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    ProSoft Technology MVI56-MCM

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.