149986-01
3500/33 relay control module
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier





Bently Nevada 149992-01 is the standard 16-channel relay output module used in the 3500/33 machinery-protection relay assembly. It provides the rear-rack switching interface for relay actions configured from the 3500 system's monitoring information.
Version check: Confirm standard relay contacts, the minimum load, 149986-01 control module and required energized/de-energized logic before replacing 149992-01.
Lifecycle status: Unknown
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Bently Nevada 149992-01 is the standard 16-channel relay output module for the 3500/33 machinery-protection relay assembly. It provides switching outputs driven by the 3500 system's monitoring information. Each relay can have its own alarm-drive logic, using AND/OR combinations of Alert, Danger and Not-OK states or measured variables from monitor channels. The module supplies the rear-rack relay interface for configured alarm and machinery-protection actions, with standard contacts across all 16 outputs.
Hardware specifications. 149992-01 uses single-pole, double-throw (SPDT) relay contacts and occupies one full-height rear I/O slot. Its dimensions are 241 × 24.4 × 99.1 mm. Normally energized or normally de-energized operation is selected in four groups of four relays. The standard contacts have a minimum switched load of 100 mA at 5 Vdc.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer | Bently Nevada |
| Complete part number | 149992-01 |
| Compatible assembly | 3500/33; control module 149986-01 |
| I/O dimensions | 241 × 24.4 × 99.1 mm (H × W × D) |
| Rack space | One full-height rear I/O slot |
Functional Configuration |
|
| Output type | Standard 16-channel relay output module |
| Contacts | SPDT |
| Relay grouping | Four groups of four; normally energized or de-energized |
Performance & Power |
|
| Minimum standard switched load | 100 mA at 5 Vdc |
| Maximum load selection | Apply voltage, current and power limits together; see contact ratings |
Environment |
|
| Relay environmental sealing | Epoxy-sealed relay construction |
System compatibility. 149992-01 pairs with the 149986-01 control module in the 3500/33 assembly. Relay alarm-drive logic is programmed using 3500 Rack Configuration Software. The minimum software versions are Rack Configuration v3.3, Data Acquisition v2.40 and Data Display v1.40. Each output has independently configurable alarm logic, while the energized/de-energized hardware mode is shared by its four-relay group.
Connection and replacement reference for 149992-01. Use the applicable monitor instructions and actual module markings.
Match each relay circuit to its actual SPDT terminal assignments.
Apply all contact voltage, current and power limits together; use the DC rating curve when selecting DC loads.
Disconnect power before service and comply with the actual module warnings.
Confirm standard, failsafe or low-current requirements before installing the module.
Check each group's mode setting, configured logic and resulting contact states before return to service.
Do not hot-insert this module; the pictured unit warns that module damage will result.
Do not disconnect live equipment unless the area is known to be non-hazardous. Follow electrical-shock and hazardous-location precautions.
For a standard 3500/33 system, the switched-power limits are 70 W at 24 Vdc, 10 W at 48 Vdc and 9 W at 60 Vdc. The contact also has a 5 A maximum-current limit and a 125 Vdc maximum-voltage limit. The power limit for the operating voltage must be satisfied together with the current limit.
For resistive AC loads in a standard system, the limits are 5 A, 250 Vac and 1,200 VA. All three apply together; for example, the 1,200 VA limit corresponds to 4.8 A at 250 Vac. Functional-safety and hazardous-area systems use their restricted ratings.
The hazardous-area contact rating limits a resistive DC load to 30 Vdc and 5 A. These restricted ratings apply within the appropriately approved 3500/33 system configuration.
On the associated 3500/33 control module, the channel’s CH Alarm LED illuminates when that relay channel is in an alarm state. The TX/RX LED flashes during rack communication, and the OK LED indicates proper module operation.
The 3500/33 relay contact-life rating is 10,000 cycles.
Yes. A 250 Vrms relay arc suppressor is installed as standard in the 3500/33 relay arrangement.
The green, 16-position internal-termination connector header is 00580453. The push-in-spring alternative is 166M2381.
Add further 3500/33 16-channel relay assemblies in available slots to the right of the Transient Data Interface module. The typical power consumption of each 3500/33 assembly is 5.8 W.
Product photographs, model-specific specifications and selected original manufacturer pages covering the applicable I/O configuration and module reference.
PDF · 6 pages · 120.9 KB · Compiled by EWOLO CONTROL. 162301 Rev. AC
Preview Product Reference (PDF)3500/33 relay control module
3500/33 failsafe relay output module
3500/33 low-current relay output module
Proximitor I/O, internal terminations
Proximitor I/O, external terminations
Proximitor I/O with internal barriers
3500/40M Proximitor monitor
Prox/Seismic I/O, internal terminations
Prox/Seismic I/O, external terminations
Internal-barrier I/O, four Prox/Accel channels
Internal-barrier I/O, Prox/Accel and Velomitor
Internal-barrier I/O, four Velomitor channels
Shaft Absolute I/O, internal terminations
Shaft Absolute I/O, external terminations
Prox/Velom I/O, internal terminations
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Bently Nevada 133819-01 is the internal-termination, non-isolated RTD/TC I/O module for the 3500/60 temperature-monitoring system. It forms the rear-rack sensor interface for a six-channel temperature monitor used to evaluate machinery temperatures and compare them with user-programmed alarm limits. Version check: Confirm the 3500/60 monitor, non-isolated RTD/TC input and internal termination arrangement before replacing 133819-01.
Bently Nevada 133827-01 is the external-termination, non-isolated RTD/TC I/O module for the 3500/60 temperature-monitoring system. It forms the rear-rack sensor interface for a six-channel temperature monitor used to evaluate machinery temperatures and compare them with user-programmed alarm limits. Version check: Confirm the 3500/60 monitor, non-isolated RTD/TC input and external termination arrangement before replacing 133827-01.
Bently Nevada 135489-01 is the Prox/Accel I/O module with internal barriers and internal terminations for the 3500/42M machinery-protection monitor. It combines the rear-rack field interface with the internal-barrier option required by a correctly engineered intrinsically safe transducer system. Version check: Confirm the 3500/42M monitor, four Prox/Accel channels and approved internal-barrier circuit before replacing 135489-01.
Bently Nevada 135489-04 is the Proximitor I/O module with internal barriers and internal terminations for the 3500/40M machinery-protection monitor. It combines the rear-rack field interface with the internal-barrier option required by a correctly engineered intrinsically safe transducer system. Version check: Confirm the 3500/40M monitor, Proximitor configuration and approved internal-barrier circuit before replacing 135489-04.
Bently Nevada 138708-01 is the internal-termination Shaft Absolute I/O module for the 3500/42M machinery-protection monitor. It provides the dedicated rear-rack interface for an appropriately configured shaft-absolute measurement assembly, with supported proximity/acceleration, Velomitor or Seismoprobe transducers. Version check: Confirm the 3500/42M M-version monitor, shaft-absolute sensor arrangement and required firmware/software revisions before replacing 138708-01.
Bently Nevada 140471-01 is the internal-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, internal terminations and 3500/42M configuration before replacing 140471-01.
Bently Nevada 140482-01 is the external-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, external terminations and 3500/42M configuration before replacing 140482-01.
Bently Nevada 149992-01 is the standard 16-channel relay output module used in the 3500/33 machinery-protection relay assembly. It provides the rear-rack switching interface for relay actions configured from the 3500 system's monitoring information. Version check: Confirm standard relay contacts, the minimum load, 149986-01 control module and required energized/de-energized logic before replacing 149992-01.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :