ISO 9001:2015 certified industrial automation spare parts supplier

Bently Nevada 149992-01 16-Channel Relay Output Module

Bently Nevada 149992-01 is the standard 16-channel relay output module used in the 3500/33 machinery-protection relay assembly. It provides the rear-rack switching interface for relay actions configured from the 3500 system's monitoring information.

Version check: Confirm standard relay contacts, the minimum load, 149986-01 control module and required energized/de-energized logic before replacing 149992-01.

Download
  • Bently Nevada 149992-01 16-Channel Relay Output Module

    Bently Nevada 149992-01 is the standard 16-channel relay output module for the 3500/33 machinery-protection relay assembly. It provides switching outputs driven by the 3500 system's monitoring information. Each relay can have its own alarm-drive logic, using AND/OR combinations of Alert, Danger and Not-OK states or measured variables from monitor channels. The module supplies the rear-rack relay interface for configured alarm and machinery-protection actions, with standard contacts across all 16 outputs.

    Hardware specifications. 149992-01 uses single-pole, double-throw (SPDT) relay contacts and occupies one full-height rear I/O slot. Its dimensions are 241 × 24.4 × 99.1 mm. Normally energized or normally de-energized operation is selected in four groups of four relays. The standard contacts have a minimum switched load of 100 mA at 5 Vdc.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer Bently Nevada
    Complete part number 149992-01
    Compatible assembly 3500/33; control module 149986-01
    I/O dimensions 241 × 24.4 × 99.1 mm (H × W × D)
    Rack space One full-height rear I/O slot

    Functional Configuration

    Output type Standard 16-channel relay output module
    Contacts SPDT
    Relay grouping Four groups of four; normally energized or de-energized

    Performance & Power

    Minimum standard switched load 100 mA at 5 Vdc
    Maximum load selection Apply voltage, current and power limits together; see contact ratings

    Environment

    Relay environmental sealing Epoxy-sealed relay construction

    Compatibility & Selection Guide

    System compatibility. 149992-01 pairs with the 149986-01 control module in the 3500/33 assembly. Relay alarm-drive logic is programmed using 3500 Rack Configuration Software. The minimum software versions are Rack Configuration v3.3, Data Acquisition v2.40 and Data Display v1.40. Each output has independently configurable alarm logic, while the energized/de-energized hardware mode is shared by its four-relay group.

    Wiring & Installation Reference

    Connection and replacement reference for 149992-01. Use the applicable monitor instructions and actual module markings.

    Field connections

    Match each relay circuit to its actual SPDT terminal assignments.

    Apply all contact voltage, current and power limits together; use the DC rating curve when selecting DC loads.

    View connection reference (PDF)

    Installation and replacement

    1. Isolate power

      Disconnect power before service and comply with the actual module warnings.

    2. Match the output variant

      Confirm standard, failsafe or low-current requirements before installing the module.

    3. Verify relay behavior

      Check each group's mode setting, configured logic and resulting contact states before return to service.

    View module reference

    Power and handling precautions

    • Do not hot-insert this module; the pictured unit warns that module damage will result.

    • Do not disconnect live equipment unless the area is known to be non-hazardous. Follow electrical-shock and hazardous-location precautions.

    Frequently Asked Questions

    What resistive DC loads can 149992-01 switch at 24, 48 and 60 Vdc?

    For a standard 3500/33 system, the switched-power limits are 70 W at 24 Vdc, 10 W at 48 Vdc and 9 W at 60 Vdc. The contact also has a 5 A maximum-current limit and a 125 Vdc maximum-voltage limit. The power limit for the operating voltage must be satisfied together with the current limit.

    What AC contact limits apply to 149992-01 in a standard system?

    For resistive AC loads in a standard system, the limits are 5 A, 250 Vac and 1,200 VA. All three apply together; for example, the 1,200 VA limit corresponds to 4.8 A at 250 Vac. Functional-safety and hazardous-area systems use their restricted ratings.

    Which DC contact limits apply to 149992-01 in an approved hazardous-area 3500/33 installation?

    The hazardous-area contact rating limits a resistive DC load to 30 Vdc and 5 A. These restricted ratings apply within the appropriately approved 3500/33 system configuration.

    Which indication identifies an active relay alarm when 149992-01 is used?

    On the associated 3500/33 control module, the channel’s CH Alarm LED illuminates when that relay channel is in an alarm state. The TX/RX LED flashes during rack communication, and the OK LED indicates proper module operation.

    What relay contact-life figure applies when planning maintenance for 149992-01?

    The 3500/33 relay contact-life rating is 10,000 cycles.

    Is an arc suppressor already fitted to the relay circuits used with 149992-01?

    Yes. A 250 Vrms relay arc suppressor is installed as standard in the 3500/33 relay arrangement.

    Which replacement field-connector header is available for the 3500/33 assembly using 149992-01?

    The green, 16-position internal-termination connector header is 00580453. The push-in-spring alternative is 166M2381.

    How can a rack be expanded beyond the outputs of one 149992-01 assembly?

    Add further 3500/33 16-channel relay assemblies in available slots to the right of the Transient Data Interface module. The typical power consumption of each 3500/33 assembly is 5.8 W.

    Manufacturer Documentation

    149992-01 Product Reference

    Product photographs, model-specific specifications and selected original manufacturer pages covering the applicable I/O configuration and module reference.

    PDF · 6 pages · 120.9 KB · Compiled by EWOLO CONTROL. 162301 Rev. AC

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Bently Nevada 149992-01

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.