ISO 9001:2015 certified industrial automation spare parts supplier

Bently Nevada 135489-04 Proximitor I/O Module with Internal Barriers

Bently Nevada 135489-04 is the Proximitor I/O module with internal barriers and internal terminations for the 3500/40M machinery-protection monitor. It combines the rear-rack field interface with the internal-barrier option required by a correctly engineered intrinsically safe transducer system.

Version check: Confirm the 3500/40M monitor, Proximitor configuration and approved internal-barrier circuit before replacing 135489-04.

Download
  • Bently Nevada 135489-04 Proximitor I/O Module with Internal Barriers

    Bently Nevada 135489-04 is the Proximitor I/O module with internal barriers and internal terminations for the 3500/40M machinery-protection monitor. It combines the rear-rack proximity-transducer interface with built-in safety barriers used in approved intrinsically safe sensor circuits. The associated four-channel monitor supports radial vibration, eccentricity, thrust position and differential expansion measurements. It continuously compares these measurements with programmed alarm limits, providing machinery-protection alarms and condition information for operations and maintenance personnel.

    Hardware specifications. 135489-04 occupies one full-height rear I/O slot and measures 241.3 × 24.4 × 163.1 mm. It uses internal field terminations and interfaces with up to four proximity-transducer channels through the 3500/40M. The barrier I/O operating temperature range is 0 to +65 °C, and its storage range is −40 to +85 °C.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer Bently Nevada
    Complete part number 135489-04
    Compatible monitor 3500/40M
    I/O dimensions 241.3 × 24.4 × 163.1 mm (H × W × D)
    Rack space One full-height rear I/O slot

    Functional Configuration

    Termination Internal
    Barrier design Internal barriers; system approval must be verified
    Transducer allocation Proximity-transducer inputs

    Performance & Power

    3500 monitor buffered output 3500/40M front-panel coaxial outputs, one per channel, 550 Ω output impedance

    Environment

    Operating temperature 0 to +65 °C
    Storage temperature −40 to +85 °C

    Compatibility & Selection Guide

    System compatibility. 135489-04 is the 3500/40M internal-barrier I/O option AA = 03. The monitor uses 3500 Rack Configuration Software; channels 1/2 and 3/4 form two programmable pairs, allowing two measurement functions to operate at the same time. The general minimum software versions are 3500/01 v2.50, 3500/02 v2.20 and 3500/03 v1.21. Alert setpoints are available for every active measured value, with Danger setpoints for any two active values per channel.

    Wiring & Installation Reference

    Connection and replacement reference for 135489-04. Use the applicable monitor instructions and actual module markings.

    Field connections

    Follow the actual module terminal markings and applicable approved barrier drawing.

    Review 3500 Internal Barriers document 141495 and the monitor user guide before connecting field circuits.

    View connection reference (PDF)

    Installation and replacement

    1. Verify the approved circuit

      Match the barrier option, transducer and approval drawing; do not infer approval from the part family.

    2. Check depth and environment

      Allow for the 163.1 mm I/O depth and the 0 to +65 °C operating range.

    3. Connect and validate

      Use the applicable installation instructions and verify channel configuration before returning the system to service.

    View module reference

    Power and handling precautions

    • Do not substitute another 135489 suffix without verifying the monitor and transducer allocation.

    • Intrinsic safety depends on the complete approved installation, not the I/O module alone.

    Frequently Asked Questions

    How does the selected full-scale range limit alarm thresholds when 135489-04 is used?

    On the 3500/40M, alarm thresholds can be set from 0–100% of each measured value’s full scale. If that span exceeds the transducer’s range, the transducer range limits the threshold. Alarm-setpoint accuracy is within 0.13% of the desired value.

    What Alert and Danger delays are available for a position channel using 135489-04?

    For 3500/40M thrust position, differential expansion and eccentricity, Alert delay is 1–60 seconds in 1-second steps. Danger delay can be 0.1 second or 1–60 seconds in 0.5-second steps. These delay options also apply to radial vibration.

    Which sensitivity settings apply to differential-expansion measurements with 135489-04?

    The 3500/40M differential-expansion settings are 0.394 mV/μm (10 mV/mil) and 0.787 mV/μm (20 mV/mil).

    How quickly do the Direct and Gap paths respond in a thrust-position setup using 135489-04?

    The 3500/40M thrust-position Direct filter has its −3 dB point at 1.2 Hz; the Gap filter has its −3 dB point at 0.41 Hz. The same filter cutoffs apply to differential expansion.

    Which eccentricity values can be trended when 135489-04 is used?

    The 3500/40M eccentricity channel supplies peak-to-peak, Gap, Direct Minimum and Direct Maximum values. This provides both the excursion and the minimum/maximum position values for the configured channel.

    What speed range supports synchronous radial-vibration analysis with 135489-04?

    With the 3500/40M configured for radial vibration, 1X and 2X vector, Not 1X and Smax parameters are valid from 60 to 60,000 cpm.

    Where can a diagnostic instrument access buffered signals with 135489-04 installed?

    Use the associated 3500/40M’s front-panel coaxial connectors, one for each channel. The buffered outputs have 550 Ω output impedance and individual short-circuit protection.

    What accuracy applies to Direct and Gap radial-vibration readings with 135489-04?

    At +25 °C, the 3500/40M signal-conditioning accuracy for Direct and Gap is ±0.33% of full scale typical and ±1% maximum, excluding filtering.

    Manufacturer Documentation

    135489-04 Product Reference

    Product photographs, model-specific specifications and selected original manufacturer pages covering the applicable I/O configuration and module reference.

    PDF · 5 pages · 114.2 KB · Compiled by EWOLO CONTROL. 141535 Rev. R

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Bently Nevada 135489-04

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.