AAI143-H50
16-Channel HART Analog Input Module
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier



Yokogawa AAI135-H50 is an eight-channel, channel-isolated 4–20 mA input module for CENTUM FIO systems. It combines process-current acquisition with HART communication and supports dual-redundant module configurations.
Version check: Confirm -H50, channel isolation, hardware Style and the installed terminal adapter; -S versions do not provide HART.
Lifecycle status: Unknown
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Yokogawa AAI135-H50 brings eight 4–20 mA field measurements into a CENTUM FIO control system. It is intended for process transmitters where each input requires isolation from the system and from the other channels. The HART version carries the analog process value while providing access to digital information from compatible field instruments. AAI135-H50 also supports dual-redundant configurations, making its channel isolation, transmitter requirements and installed redundancy arrangement important checks when selecting a maintenance spare.
Hardware specifications. AAI135-H50 provides eight inputs with a 10 ms data update period and ±16 µA accuracy. The allowable input current is 25 mA. Transmitter supply is at least 15.0 V at 20 mA; available voltage must account for cable drop. Maximum module consumption is 360 mA at 5 V DC and 450 mA at 24 V DC. The basic module measures 32.8 × 130 × 107.5 mm (W × H × D).
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer | Yokogawa |
| Complete model | AAI135-H50 |
| Dimensions (W × H × D) | 32.8 × 130 × 107.5 mm; module only |
Functional Configuration |
|
| Function | Analog input with HART communication |
| Input channels | 8; isolated between channels and from the system |
| Input signal | 4–20 mA DC |
| Redundancy | Dual-redundant configuration supported |
Performance & Power |
|
| Allowable input current | 25 mA |
| Accuracy | ±16 µA |
| Data update period | 10 ms |
| Transmitter supply | At least 15.0 V at 20 mA; allow for wiring voltage drop |
| Maximum current consumption | 360 mA at 5 V DC; 450 mA at 24 V DC |
Environment |
|
| Protection option | Standard version without explosion protection |
System compatibility. AAI135-H50 is part of the CENTUM FIO family. The Release 6 application environment includes AFV30/AFV40 field control stations with VP6F1700 control functions and VP6E5100 engineering. Preserve the complete -H50 code when replacing a module: H identifies HART, 5 identifies the non-explosion-protected version and 0 the basic type. Confirm the installed system release and terminal-adapter option.
Use the matching Yokogawa system and connection instructions for the installed assembly. The checks below are specific to AAI135-H50.
| Item | Requirement | Check |
|---|---|---|
| Signal | 4–20 mA DC | Maximum allowable current 25 mA |
| Transmitter supply | ≥15.0 V at 20 mA | Allow for cable voltage drop |
| Barrier selection | Isolation barrier | Do not connect a Zener barrier |
Match the field control unit, node type, complete module code and existing configuration before replacement.
Use the specified terminal/cable interface and check the module envelope against the installed assembly.
Confirm -H50, channel isolation, hardware Style and the installed terminal adapter; -S versions do not provide HART.
Do not connect a Zener barrier. Use the appropriate isolation barrier for an intrinsically safe application.
Choose the specified terminal or cable interface; cable electrical ratings can limit the complete installation isolation rating.
It receives eight 4–20 mA process signals and transfers them to the FIO control system. The -H version also supports HART communication with compatible field instruments.
Yes. Its eight inputs are isolated both from the system and from one another. This differs from modules described only as isolated between field signals and the system.
Yes. The H suffix identifies the HART communication version. A standard -S version is not an equivalent choice when HART functions are required.
Its nominal input range is 4–20 mA DC, with an allowable input current of 25 mA.
The data update period is 10 ms. This is the module update interval, not a guarantee of the complete control-loop response time.
The transmitter supply is at least 15.0 V at 20 mA and no more than 29.3 V at zero current. Check the transmitter minimum operating voltage after allowing for external wiring drop.
No. Use an isolation barrier for intrinsically safe applications; a Zener barrier must not be connected to this module.
Yes. It supports dual-redundant configurations. Match the module specification and the single or dual terminal arrangement to the installed design.
Check the actual ordered option and existing termination. Available choices include ATI3S-00 single pressure-clamp, ATI3D-00 dual pressure-clamp, ATI3A-00 and ATK4A-00 cable-interface adapters; the base code alone does not include a particular adapter.
Product photograph, model identification and compatibility notes, followed by selected Yokogawa pages covering specifications, dimensions and ordering codes.
PDF · 5 pages · 99.4 KB · Compiled by EWOLO CONTROL. Manufacturer extracts: GS 33J60F60-01EN, 6th Edition, 2017-03-20.
Preview Product Reference (PDF)16-Channel HART Analog Input Module
16-Channel HART Analog Output Module
8-Input 8-Output HART Analog I/O Module
8-Channel Isolated Pulse Input Module
32-Channel 24V DC Digital Input Module
32-Channel 24V DC Digital Output Module
2-Port RS-422 RS-485 Communication Module
1-Port ESB Bus Coupler Module
2-Port ESB Bus Coupler Module
16-channel non-isolated 4–20 mA input module
16-channel non-isolated 1–5 V input module
16-channel HART 1–5 V / 4–20 mA input module
4-input/4-output isolated-channel HART module
16-channel isolated TC/mV input module
16-channel isolated RTD/POT input module
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Yokogawa AAI543-H50 is a 16-channel isolated 4–20 mA output module for CENTUM FIO. It supports HART communication and standard-response switching in a dual-redundant configuration. Version check: Match the -H50 standard switchover response, hardware Style and terminal option; a redundant pair must use the same response class.
Yokogawa AAI841-H00 is a non-isolated FIO module with eight 4–20 mA inputs and eight 4–20 mA outputs. It supports up to eight loops, HART communication and dual-redundant configurations. Version check: Confirm the legacy -H00 code, hardware Style, node and terminal option; HART in an ER-bus remote node requires EB401 Rev. 2 or later.
Yokogawa AAP135-S50 is an eight-channel isolated pulse input module for CENTUM FIO. It accepts contact, voltage-pulse and current-pulse signals, with frequency limits determined by the selected signal and redundancy configuration. Version check: Match pulse source, frequency, transmitter supply and redundancy mode; dry-contact limits are lower than the 10 kHz electronic-pulse limit.
Yokogawa ADV151-P60 is a 32-channel 24 V DC digital input module for CENTUM FIO. The P version supports pushbutton input, and suffix 6 provides input-status display without explosion protection. Version check: Confirm -P60 pushbutton capability, status display, hardware Style and input polarity; do not substitute an output or SOE-capture version.
Yokogawa ADV551-P60 is a 32-channel current-sink transistor output module for CENTUM FIO. It supports status, pulse-width and time-proportioning output patterns with output-status display. Version check: Match -P60, sink-output load and configured point-mode pattern; check paired-channel and redundancy restrictions before replacement.
Yokogawa ALR121-S50 is a two-port RS-422/RS-485 serial communication module for CENTUM N-IO/FIO systems. It exchanges subsystem data with the FCS using supported functions such as Modbus RTU and FA-M3 communication. Version check: Confirm RS-422/RS-485, the common protocol selected for both ports, baud rate, data mapping and the installed redundancy arrangement.
Yokogawa EC401-50 is a one-port ESB bus coupler for CENTUM N-IO/FIO. It links the field control unit to supported ESB nodes at 128 Mbps and supports single or dual-redundant module arrangements. Version check: For a CP471 system, require EC401 Style S3 or later; also match the one-port ESB topology, node types and redundancy arrangement.
Yokogawa EC402-50 is a two-port ESB bus coupler for CENTUM N-IO/FIO. Its upper and lower ESB connections link supported field control units to I/O nodes at 128 Mbps. Version check: Match the two-port ESB topology and system release; the 12-nodes-per-port exception applies only to the specified A2FV50 star configuration.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :