Yokogawa EC402-50 2-Port ESB Bus Coupler Module

Yokogawa EC402-50 is a two-port ESB bus coupler for CENTUM N-IO/FIO. Its upper and lower ESB connections link supported field control units to I/O nodes at 128 Mbps.

Version check: Match the two-port ESB topology and system release; the 12-nodes-per-port exception applies only to the specified A2FV50 star configuration.

Download
  • Yokogawa EC402-50 2-Port ESB Bus Coupler Module

    Yokogawa EC402-50 provides two ESB bus connections between a CENTUM field control unit and supported I/O nodes. The upper and lower ports give the system separate ESB connection paths for node expansion while retaining the supported single or dual-redundant coupler arrangement. EC402-50 is a system-bus interface rather than an Ethernet switch. Its node capacity must be checked against the exact field-control-unit and system release, because the higher per-port allowance is limited to a specific configuration.

    Hardware specifications. EC402-50 transfers I/O data at 128 Mbps through two ESB ports. The standard allowance is nine specified nodes on the upper port and nine on the lower port. Each ESB cable path is limited to 10 m, or 20 m across both paths. Current consumption is 0.5 A. The module measures 32.8 × 130 × 129.5 mm (W × H × D).

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer Yokogawa
    Complete model EC402-50
    Ordering code -50: standard, no explosion protection, basic type
    Dimensions (W × H × D) 32.8 × 130 × 129.5 mm

    Functional Configuration

    Function ESB bus coupler for N-IO/FIO
    Ports 2 ESB bus ports; upper and lower
    Standard node capacity 9 upper + 9 lower specified node/interface units
    Special node-capacity condition 12 per port only for the specified A2FV50S/D star connection, ANT4□1 and CENTUM VP R6.06 or later
    Single / redundant arrangement Single module in slot 7; redundant modules in slots 7 and 8

    Performance & Power

    I/O data transmission speed 128 Mbps
    Maximum ESB cable length 10 m per port path; 20 m combined
    Current consumption 0.5 A

    Environment

    Protection option Standard version without explosion protection

    Compatibility & Selection Guide

    System compatibility. EC402-50 supports the specified AFV30/AFV40, A2FV50 and A2FV70 field control units. The allowance of twelve nodes per port applies only to the specified A2FV50S/D star connection using ANT4□1 and CENTUM VP R6.06 or later. Match the field control unit, release, node/interface types and redundancy arrangement; do not apply that exception to every installation.

    Wiring & Installation Reference

    Use the matching Yokogawa system and connection instructions for the installed assembly. The checks below are specific to EC402-50.

    Signal and connection checks

    Item Requirement Check
    Upper ESB path 10 m maximum Standard allowance 9 specified nodes
    Lower ESB path 10 m maximum Standard allowance 9 specified nodes
    Special capacity 12 per port conditionally A2FV50 star / ANT4□1 / R6.06 or later

    View connection specifications (PDF)

    Module fit and configuration

    1. Single configuration.

      Install the coupler in slot 7 with the specified dummy module in slot 8.

    2. Dual-redundant configuration.

      Use the specified pair in slots 7 and 8; confirm the existing node and bus arrangement.

    3. Check the system conditions.

      Match the two-port ESB topology and system release; the 12-nodes-per-port exception applies only to the specified A2FV50 star configuration.

    View mounting dimensions (PDF)

    Power and handling precautions

    • Apply the higher node limit only when every specified A2FV50 star-connection condition is satisfied.

    • Confirm each cable path separately and match the single or dual-redundant slot arrangement.

    Frequently Asked Questions

    What is the role of EC402-50 in a CENTUM system?

    It couples a supported field control unit to ESB-bus I/O nodes through two ESB ports.

    How many ports does EC402-50 provide?

    It has an upper and a lower ESB bus port. These are ESB system connections, not general-purpose Ethernet ports.

    What is the standard node capacity of EC402-50?

    The standard allowance is nine specified node/interface units on each port: nine upper and nine lower.

    When can EC402-50 support twelve nodes per port?

    Only in the specified A2FV50S/D star connection using ANT4□1 with CENTUM VP R6.06 or later. Verify all those conditions before using the higher allowance.

    What cable-length limit applies to EC402-50?

    Each upper or lower ESB cable path is limited to 10 m. The combined length across both paths is 20 m.

    What communication speed does EC402-50 use?

    The ESB I/O-data transmission speed is 128 Mbps.

    Where is EC402-50 installed in a single configuration?

    It occupies slot 7, with a dummy module in slot 8 in the specified single arrangement.

    Can EC402-50 be used in a redundant arrangement?

    Yes. The specified redundant configuration uses two modules in slots 7 and 8. Confirm the supported field control unit and existing node topology.

    What should be checked before replacing EC402-50?

    Match the complete -50 code, hardware Style, field control unit, system release, node/interface types, upper/lower cable paths and redundancy configuration. Do not assume the twelve-node exception applies to all systems.

    Manufacturer Documentation

    EC402-50 Product Reference

    Product photograph, model identification and compatibility notes, followed by selected Yokogawa pages covering specifications, dimensions and ordering codes.

    PDF · 4 pages · 96.0 KB · Compiled by EWOLO CONTROL. Manufacturer extracts: GS 33J60E51-01EN, 5th Edition, 2020-11-05.

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Yokogawa EC402-50

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.