ISO 9001:2015 certified industrial automation spare parts supplier

Vibro Meter EA402 913-402-000-013 A2-E040-F1-G030 Proximity Probe Extension Cable

EA402 913-402-000-013 A2-E040-F1-G030 is a 4 m matched extension cable for the TQ402/TQ412–IQS450 chain, with 3 m of flexible stainless-steel hose.

Version check: Match the full A2-E040-F1-G030 cable code, probe integral length and IQS450 total-system-length option; do not substitute by cable length alone.

Download
  • Vibro Meter EA402 913-402-000-013 A2-E040-F1-G030 Proximity Probe Extension Cable

    Vibro Meter EA402 913-402-000-013 A2-E040-F1-G030 is the matched extension cable used between a TQ402 or TQ412 proximity transducer and an IQS450 signal conditioner. It forms part of the calibrated eddy-current measurement chain used for non-contact shaft vibration and position measurements. The visible E040 code identifies a nominal 4 m cable, while F1-G030 specifies flexible stainless-steel protection over 3 m. Its coaxial construction and keyed self-locking connectors carry the probe signal without converting it into a standalone process output.

    Hardware specifications. The extension uses FEP-covered 70-ohm coaxial cable with a nominal diameter of 3.6 mm. E040 specifies 4.0 m ±400 mm; the protected hose length is separately coded G030. The F1 hose provides mechanical protection but is not leak-tight. General cable and connector specifications cover −40 to +200 °C; for the A2 intrinsically safe transducer-and-cable configuration, the applicable Ex-zone range is −40 to +195 °C.

    Technical Specifications

    Parameter Specification

    Product Identity

    Product type Matched proximity probe extension cable
    Cable construction FEP-covered 70 Ω coaxial cable, 3.6 mm nominal diameter

    Functional Configuration

    Complete cable code EA402 913-402-000-013 A2-E040-F1-G030
    Measurement chain TQ402/TQ412 with IQS450
    Nominal extension length E040: 4.0 m ±400 mm
    Protection option F1: flexible stainless-steel hose, no connector protector
    Hose length G030: 3.0 m
    Connectors Self-locking miniature coaxial female and male

    Performance & Power

    Minimum bend radii FEP cable: 20 mm; stainless-steel hose: 50 mm

    Environment

    Environment option A2; assess complete Ex i chain
    Cable temperature A2 Ex-zone transducer and cable: −40 to +195 °C; general cable/connector rating: −40 to +200 °C

    Compatibility & Selection Guide

    System compatibility. Select the EA402 together with the probe integral cable and the IQS450 total-system-length option. Cable electrical trimming is part of the calibrated system, so nominal physical length alone does not establish interchangeability. The A2 option belongs to the intrinsically safe configuration and must be checked against the complete chain and applicable certificate.

    Wiring & Installation Reference

    Use the EA402 assembly drawing and system-length guidance for the complete probe chain.

    Probe-chain connections

    Connect the female and male self-locking coaxial ends to the corresponding probe cable and signal conditioner.

    Keep connectors correctly seated and use the required environmental protection.

    View cable assembly (PDF)

    Cable routing

    1. Match total system length

      Check the probe integral cable, EA402 extension and IQS450 length option as a single measuring chain.

    2. Maintain bend radii

      Allow at least 20 mm for bare FEP cable and 50 mm for the stainless-steel hose.

    3. Protect the connections

      F1 hose is mechanical protection and is not leak-tight; apply the specified connector protection where required.

    View mounting diagram

    Power and handling precautions

    • Do not shorten or splice a calibrated extension cable as though it were generic wiring.

    • For the A2 intrinsically safe transducer-and-cable configuration, respect the −40 to +195 °C Ex-zone range and all conditions of the complete certified chain.

    Frequently Asked Questions

    What is EA402 913-402-000-013 A2-E040-F1-G030 used for?

    It extends the connection between a TQ402/TQ412 proximity probe and its IQS450 signal conditioner within a matched eddy-current measurement chain.

    How long is the cable in EA402 913-402-000-013 A2-E040-F1-G030?

    E040 specifies a nominal 4.0 m extension cable with ±400 mm tolerance. G030 separately specifies 3.0 m of flexible protective hose.

    Does EA402 913-402-000-013 A2-E040-F1-G030 have a 4 m or 3 m measuring-system length?

    Neither code alone defines the total system length. Add the probe integral cable and select the matching IQS450 system-length configuration; E040 is the extension length and G030 is hose length.

    Can EA402 913-402-000-013 A2-E040-F1-G030 be shortened to fit a cable route?

    Do not treat it as generic field-cut cable. The cable characteristics and electrical trimming are part of the calibrated probe/conditioner system. Obtain the matched cable configuration for the required length.

    Is the protective hose of EA402 913-402-000-013 A2-E040-F1-G030 waterproof?

    No. F1 flexible stainless-steel hose provides mechanical protection but is not leak-tight. Confirm any additional connector/environmental protection required by the application.

    What bend radii apply to EA402 913-402-000-013 A2-E040-F1-G030?

    Maintain at least 20 mm bend radius for the FEP coaxial cable and 50 mm for the flexible stainless-steel hose.

    What does the A2 code in EA402 913-402-000-013 A2-E040-F1-G030 mean?

    It identifies the intrinsically safe ordering option. Hazardous-area suitability still depends on the complete transducer, cable, conditioner, barrier and applicable certificate conditions.

    What connectors are used on EA402 913-402-000-013 A2-E040-F1-G030?

    It uses self-locking miniature coaxial female and male connectors. Match the corresponding probe and IQS450 connections and seat them fully.

    What temperature limit applies to EA402 913-402-000-013 A2-E040-F1-G030?

    For the A2 intrinsically safe transducer-and-cable configuration, use the −40 to +195 °C Ex-zone range and respect the complete chain certificate conditions. The general −40 to +200 °C cable/connector rating does not override this Ex limit.

    Manufacturer Documentation

    EA402 913-402-000-013 A2-E040-F1-G030 Product Reference

    Actual product photograph, application and replacement notes, with selected manufacturer pages covering specifications and connection or mechanical details.

    PDF · 6 pages · 68.0 KB · Compiled by EWOLO CONTROL. DS 265-062 Version 7 (2015-03-05).

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Vibro Meter EA402 913-402-000-013 A2-E040-F1-G030

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.