CA134 144-134-000-613
CA134 integral-cable replacement variant
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier




IQS450 204-450-000-001 A2-B23-H10-I0 is a legacy proximity-system conditioner marked for 4 mV/µm, a 10 m measurement chain and VCL 140 target material. Later IQS450 parameters are provided as reference.
Version check: Match the 001 AMP connector, B23 voltage sensitivity and 10 m calibrated chain; the newer 002 connector and current-output B24 option are different.
Lifecycle status: Unknown
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Vibro Meter IQS450 204-450-000-001 A2-B23-H10-I0 is a conditioner for a non-contact eddy-current proximity measurement chain, used to monitor shaft-relative movement and position. The IQS450 family drives a compatible probe and converts the probe-target gap into a proportional electrical output. The actual unit is marked for TQ4X2 probes, 4 mV/µm voltage sensitivity, 10 m cable length and VCL 140 target material. Its legacy 001 AMP-type coaxial interface is a key replacement distinction from the newer 002 self-locking connector.
Hardware specifications. The later B23 reference uses a typical 0.3-4.3 mm linear gap range and -1.6 to -17.6 V output. The newer IQS450 reference supply is -20 to -32 V with temperature-dependent derating, and its conditioner operating range is -35 to +85 °C. These newer 002 performance limits remain reference data; the actual 001 nameplate independently confirms the stated sensitivity, chain length and target material.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Complete legacy configuration | IQS450 204-450-000-001 A2-B23-H10-I0 |
Functional Configuration |
|
| Photographed sensitivity | 4 mV/µm; voltage-output calibration |
| Photographed chain length | 10 m; total calibrated measurement chain |
| Photographed target material | VCL 140 |
| Input connector | 001: AMP-type miniature coaxial connector |
| Reference data scope | IQS450 002 / B23 parameters, 265-062 Version 7 |
| Linear range - newer B23 reference | 0.3-4.3 mm typical |
| Output - newer B23 reference | -1.6 to -17.6 V |
| Mounting configuration | I0; photographed without MA130 DIN-rail adaptor |
Performance & Power |
|
| Supply - newer reference | -20 to -32 V; thermal derating applies |
Environment |
|
| Temperature - newer reference | -35 to +85 °C for conditioner, with supply derating |
System compatibility. Match the probe, extension cable, total calibrated chain length, target material and voltage-input monitor as a complete system. The I0 unit is photographed without a DIN-rail adaptor. Preserve the legacy connector type and check the applicable A2 certificate conditions for the actual installation; newer-family certification and component interchangeability must not be assumed for an unmatched chain.
Use the newer manufacturer reference to compare the arrangement; confirm the legacy unit and complete measurement chain before applying connection or mounting details.
Retain the 001 AMP connector and match the probe/cable interface before replacement.
Compare the marked -24, COM and O/P terminals with the voltage-output reference; confirm actual polarity and legacy ratings before power is applied.
Compare the bare I0 mounting pattern with the newer reference drawing; an I1 DIN-rail adaptor is a different option.
Check supply-voltage derating together with ambient temperature.
Keep the probe, cable length and target-material calibration matched.
Apply only the hazardous-area certificate and measurement-chain conditions covering the actual legacy configuration.
It drives a compatible eddy-current proximity probe and conditions the gap signal for shaft-relative vibration or position monitoring.
No. Its actual marking is B23 with 4 mV/µm voltage sensitivity. B24 is a different current-output configuration.
It identifies the calibrated total measurement-chain length. Match the probe integral cable and any extension cable as a complete chain; do not treat 10 m as an included loose cable.
VCL 140 is marked on the photographed unit. A different target alloy can require different calibration, so confirm the actual shaft material.
No. The 001 version uses an AMP-type miniature coaxial connector, while the 002 version uses a self-locking miniature coaxial connector.
The newer B23 reference is a typical 0.3-4.3 mm gap range with -1.6 to -17.6 V output. Verify the legacy unit calibration before using these limits for setup.
No. The newer IQS450 supply range is temperature-derated. Confirm the actual legacy rating and follow the applicable derating limits rather than combining independent maximum values.
The photographed I0 unit has no MA130 DIN-rail adaptor. Confirm the included mounting hardware in the quotation.
No. Match the actual unit marking, applicable certificate, barrier and complete chain conditions. Do not substitute a newer certificate solely because the family name is the same.
Actual legacy-model photograph and version checks, with selected newer manufacturer pages. Reference parameters are not proof of unchanged legacy ratings or interchangeability.
PDF · 7 pages · 106.6 KB · Compiled by EWOLO CONTROL. 265-062 Version 7 (2015-03-05); newer revision reference.
Preview Product Reference (PDF)CA134 integral-cable replacement variant
CA134 sensor-only version
Proximity transducer for relative shaft measurements
Reverse-mount proximity transducer
Matched proximity extension cable family
Proximity signal conditioner family
Configurable galvanic separation unit
Configurable piezoelectric signal conditioner
Piezoelectric signal conditioner in GSI127 chains
Velocity sensor with integrated electronics
IEPE piezoelectric vibration sensor
IEPE vibration sensor
Legacy IEPE vibration sensor
Legacy IEPE vibration sensor
Legacy IEPE vibration sensor
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
IQS450 204-450-000-002 A2-B24-H10-I1 is the 4 mm current-output IQS450 configuration for a 10 m TQ402/TQ412 proximity measurement chain. Version check: Confirm B24 current output, H10 total cable length, I1 mounting and target-material calibration; B23 voltage units are not interchangeable by appearance.
IPC704P-CP237 244-704-000-042 is a configured IPC704 charge-to-current conditioner for a CP237 dynamic-pressure measurement chain. Version check: Match the CP237 sensor calibration, output scaling and actual HP/LP cutoffs; 032, 042 and 511 suffixes are not automatic substitutes.
CA134 144-134-000-612 is a passive 10 pC/g charge-output accelerometer for high-temperature machinery vibration measurement. Version check: Confirm the legacy 612 part versus the manufacturer-identified 613 replacement, cable arrangement and applicable temperature/approval conditions.
CA202 144-202-000-205 is a legacy CA202 charge-output accelerometer for industrial vibration measurement. Newer CA202 specifications are provided as reference; confirm the offered cable assembly and calibration. Version check: Match the full 205 part number, integral cable and calibration; newer 206/216 ordering options do not establish the legacy cable length or approval.
CA202 144-202-000-215 is a legacy CA202 charge-output accelerometer for industrial vibration measurement. Newer CA202 specifications are provided as reference; confirm the offered cable assembly and calibration. Version check: Match the full 215 part number, integral cable and calibration; newer 206/216 ordering options do not establish the legacy cable length or approval.
IPC704 244-704-000-032 is a legacy IPC704 charge signal conditioner. The photographed unit carries CP237 calibration markings; later IPC704 parameters are provided as reference. Version check: Match the 032 PNR, CP237 calibration and actual HP/LP filters; later 042/511 specifications do not prove interchangeability.
IQS450 204-450-000-001 A2-B23-H10-I0 is a legacy proximity-system conditioner marked for 4 mV/µm, a 10 m measurement chain and VCL 140 target material. Later IQS450 parameters are provided as reference. Version check: Match the 001 AMP connector, B23 voltage sensitivity and 10 m calibrated chain; the newer 002 connector and current-output B24 option are different.
VM600 MPC4 200-510-041-021 is a legacy VM600 machinery-protection card. Later MPC4 parameters are provided as reference; retain the full 041-021 revision when matching the installed rack. Version check: Match the 041-021 revision, IOC4T pair and configuration software; newer output impedance, SIL claims and firmware compatibility do not automatically apply.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :