ISO 9001:2015 certified industrial automation spare parts supplier

Vibro Meter IQS450 204-450-000-001 A2-B23-H10-I0 Proximity Signal Conditioner

IQS450 204-450-000-001 A2-B23-H10-I0 is a legacy proximity-system conditioner marked for 4 mV/µm, a 10 m measurement chain and VCL 140 target material. Later IQS450 parameters are provided as reference.

Version check: Match the 001 AMP connector, B23 voltage sensitivity and 10 m calibrated chain; the newer 002 connector and current-output B24 option are different.

Download
  • Vibro Meter IQS450 204-450-000-001 A2-B23-H10-I0 Proximity Signal Conditioner

    Vibro Meter IQS450 204-450-000-001 A2-B23-H10-I0 is a conditioner for a non-contact eddy-current proximity measurement chain, used to monitor shaft-relative movement and position. The IQS450 family drives a compatible probe and converts the probe-target gap into a proportional electrical output. The actual unit is marked for TQ4X2 probes, 4 mV/µm voltage sensitivity, 10 m cable length and VCL 140 target material. Its legacy 001 AMP-type coaxial interface is a key replacement distinction from the newer 002 self-locking connector.

    Hardware specifications. The later B23 reference uses a typical 0.3-4.3 mm linear gap range and -1.6 to -17.6 V output. The newer IQS450 reference supply is -20 to -32 V with temperature-dependent derating, and its conditioner operating range is -35 to +85 °C. These newer 002 performance limits remain reference data; the actual 001 nameplate independently confirms the stated sensitivity, chain length and target material.

    Technical Specifications

    Parameter Specification

    Product Identity

    Complete legacy configuration IQS450 204-450-000-001 A2-B23-H10-I0

    Functional Configuration

    Photographed sensitivity 4 mV/µm; voltage-output calibration
    Photographed chain length 10 m; total calibrated measurement chain
    Photographed target material VCL 140
    Input connector 001: AMP-type miniature coaxial connector
    Reference data scope IQS450 002 / B23 parameters, 265-062 Version 7
    Linear range - newer B23 reference 0.3-4.3 mm typical
    Output - newer B23 reference -1.6 to -17.6 V
    Mounting configuration I0; photographed without MA130 DIN-rail adaptor

    Performance & Power

    Supply - newer reference -20 to -32 V; thermal derating applies

    Environment

    Temperature - newer reference -35 to +85 °C for conditioner, with supply derating

    Compatibility & Selection Guide

    System compatibility. Match the probe, extension cable, total calibrated chain length, target material and voltage-input monitor as a complete system. The I0 unit is photographed without a DIN-rail adaptor. Preserve the legacy connector type and check the applicable A2 certificate conditions for the actual installation; newer-family certification and component interchangeability must not be assumed for an unmatched chain.

    Wiring & Installation Reference

    Use the newer manufacturer reference to compare the arrangement; confirm the legacy unit and complete measurement chain before applying connection or mounting details.

    Legacy connector and voltage output

    Retain the 001 AMP connector and match the probe/cable interface before replacement.

    Compare the marked -24, COM and O/P terminals with the voltage-output reference; confirm actual polarity and legacy ratings before power is applied.

    View connection reference (PDF)

    Mounting and thermal reference

    Compare the bare I0 mounting pattern with the newer reference drawing; an I1 DIN-rail adaptor is a different option.

    Check supply-voltage derating together with ambient temperature.

    View thermal reference (PDF)

    Power and handling precautions

    • Keep the probe, cable length and target-material calibration matched.

    • Apply only the hazardous-area certificate and measurement-chain conditions covering the actual legacy configuration.

    Frequently Asked Questions

    What does IQS450 204-450-000-001 A2-B23-H10-I0 do?

    It drives a compatible eddy-current proximity probe and conditions the gap signal for shaft-relative vibration or position monitoring.

    Is IQS450 204-450-000-001 A2-B23-H10-I0 the current-output B24 configuration?

    No. Its actual marking is B23 with 4 mV/µm voltage sensitivity. B24 is a different current-output configuration.

    What does the 10 m marking on IQS450 204-450-000-001 A2-B23-H10-I0 refer to?

    It identifies the calibrated total measurement-chain length. Match the probe integral cable and any extension cable as a complete chain; do not treat 10 m as an included loose cable.

    Which target material is marked for IQS450 204-450-000-001 A2-B23-H10-I0?

    VCL 140 is marked on the photographed unit. A different target alloy can require different calibration, so confirm the actual shaft material.

    Does IQS450 204-450-000-001 A2-B23-H10-I0 use the same connector as the newer 002 version?

    No. The 001 version uses an AMP-type miniature coaxial connector, while the 002 version uses a self-locking miniature coaxial connector.

    Which gap range is provided as reference for IQS450 204-450-000-001 A2-B23-H10-I0?

    The newer B23 reference is a typical 0.3-4.3 mm gap range with -1.6 to -17.6 V output. Verify the legacy unit calibration before using these limits for setup.

    Can the maximum reference supply for IQS450 204-450-000-001 A2-B23-H10-I0 be used at every temperature?

    No. The newer IQS450 supply range is temperature-derated. Confirm the actual legacy rating and follow the applicable derating limits rather than combining independent maximum values.

    Does IQS450 204-450-000-001 A2-B23-H10-I0 include a DIN-rail adaptor?

    The photographed I0 unit has no MA130 DIN-rail adaptor. Confirm the included mounting hardware in the quotation.

    Does the A2 code on IQS450 204-450-000-001 A2-B23-H10-I0 alone prove installation compliance?

    No. Match the actual unit marking, applicable certificate, barrier and complete chain conditions. Do not substitute a newer certificate solely because the family name is the same.

    Manufacturer Documentation

    IQS450 204-450-000-001 A2-B23-H10-I0 Product Reference

    Actual legacy-model photograph and version checks, with selected newer manufacturer pages. Reference parameters are not proof of unchanged legacy ratings or interchangeability.

    PDF · 7 pages · 106.6 KB · Compiled by EWOLO CONTROL. 265-062 Version 7 (2015-03-05); newer revision reference.

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Vibro Meter IQS450 204-450-000-001 A2-B23-H10-I0

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message