CA134 144-134-000-613
CA134 integral-cable replacement variant
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier



IPC704 244-704-000-032 is a legacy IPC704 charge signal conditioner. The photographed unit carries CP237 calibration markings; later IPC704 parameters are provided as reference.
Version check: Match the 032 PNR, CP237 calibration and actual HP/LP filters; later 042/511 specifications do not prove interchangeability.
Lifecycle status: Discontinued
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Vibro Meter IPC704 244-704-000-032 is a legacy conditioner in the IPC704 piezoelectric measurement family. It interfaces a sensor charge signal with monitoring electronics, using amplification and filtering appropriate to the configured measurement chain. The photographed unit carries an IPC704P-CP237 marking with a 7.5 pC/kPa input calibration and 50 µA/kPa output scaling. These visible calibration details help identify the pressure-measurement configuration, while the full 032 part number distinguishes it from later IPC704 hardware.
Hardware specifications. The later IPC704 reference specifies an 18-30 V DC supply, 25 mA maximum consumption and configurable high-pass/low-pass filtering. Its current-output reference is a 12 mA standing current with a maximum ±5 mA dynamic component. These are newer 042/511 reference values, not independently confirmed ratings for the legacy 032. The actual filter cutoffs remain configuration-specific.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Complete legacy part number | IPC704 244-704-000-032 |
Functional Configuration |
|
| Visible unit configuration | IPC704P-CP237; manufacturer calibration marking |
| Photographed input calibration | 7.5 pC/kPa |
| Photographed output scaling | 50 µA/kPa |
| Reference data scope | IPC704 262-710 Version 12, later 042/511 variants |
| Filtering | Configured HP/LP cutoffs; exact installed settings require confirmation |
| Dynamic-pressure chain | Suitable GSI galvanic separation unit required |
| Legacy equivalence | 032-to-042/511 interchangeability not established |
Performance & Power |
|
| Supply - newer reference | 18-30 V DC; 25 mA maximum |
| Current transmission - newer reference | 12 mA ±0.5 mA standing current; ±5 mA peak dynamic component |
Environment |
|
| Environmental protection with optional housing | The optional ABA160 housing encloses one IPC704 and provides IP66 enclosure protection. |
System compatibility. Match the complete CP237 sensor and conditioner calibration, output scaling and monitor interface. A suitable GSI galvanic separation unit is required for dynamic-pressure measurement chains. The later 042 and 511 versions have different sensor-material applicability, so neither a common housing nor an IPC704 family name proves an equivalent replacement.
Use the newer manufacturer reference to compare the arrangement; confirm the legacy unit and complete measurement chain before applying connection or mounting details.
Compare the marked I/P+, COM and +24 terminals with the installed measurement chain.
The later current-output diagram uses +24V and COM; verify the actual legacy supply and connections before energising.
Compare the conditioner mounting holes and enclosure with the reference drawing.
An external industrial enclosure is separate from the bare conditioner; confirm the actual installation protection.
Dynamic-pressure sensors require a suitable GSI galvanic separation unit.
Do not transfer newer supply limits, approval conditions or filter selections to the legacy unit without checking applicability.
It conditions piezoelectric sensor charge for monitoring electronics. The photographed unit is marked IPC704P-CP237 for a dynamic-pressure measurement configuration.
The photographed calibration marking is 7.5 pC/kPa at the input and 50 µA/kPa at the output. Match the offered unit and sensor calibration before ordering.
Newer IPC704 versions use an 18-30 V DC supply and draw a maximum of 25 mA. Confirm the legacy 032 supply rating before applying that range.
No. The later IPC704 current reference uses a 12 mA standing current with a maximum ±5 mA dynamic component. Use the actual configured scaling and a compatible dynamic measurement input.
Yes. Use a suitable GSI galvanic separation unit for the dynamic-pressure transducer chain and verify the complete system configuration.
No. High-pass and low-pass settings are configurable. Confirm the offered unit settings and the required measurement band.
No. The later 042 specifications are a reference here; they do not establish an unchanged configuration or direct replacement for 032.
No. The 511 reference is intended for GaPO4 sensors. Match sensor material, calibration and the complete conditioner configuration.
Provide the full 032 PNR, CP237 sensor identification, input/output calibration, filter settings and the installed GSI/monitor arrangement so the offered unit can be compared.
Actual legacy-model photograph and version checks, with selected newer manufacturer pages. Reference parameters are not proof of unchanged legacy ratings or interchangeability.
PDF · 4 pages · 108.6 KB · Compiled by EWOLO CONTROL. 262-710 Version 12 (2017-11-08); newer revision reference.
Preview Product Reference (PDF)CA134 integral-cable replacement variant
CA134 sensor-only version
Proximity transducer for relative shaft measurements
Reverse-mount proximity transducer
Matched proximity extension cable family
Proximity signal conditioner family
Configurable galvanic separation unit
Configurable piezoelectric signal conditioner
Piezoelectric signal conditioner in GSI127 chains
Velocity sensor with integrated electronics
IEPE piezoelectric vibration sensor
IEPE vibration sensor
Legacy IEPE vibration sensor
Legacy IEPE vibration sensor
Legacy IEPE vibration sensor
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
IQS450 204-450-000-002 A2-B24-H10-I1 is the 4 mm current-output IQS450 configuration for a 10 m TQ402/TQ412 proximity measurement chain. Version check: Confirm B24 current output, H10 total cable length, I1 mounting and target-material calibration; B23 voltage units are not interchangeable by appearance.
IPC704P-CP237 244-704-000-042 is a configured IPC704 charge-to-current conditioner for a CP237 dynamic-pressure measurement chain. Version check: Match the CP237 sensor calibration, output scaling and actual HP/LP cutoffs; 032, 042 and 511 suffixes are not automatic substitutes.
CA134 144-134-000-612 is a passive 10 pC/g charge-output accelerometer for high-temperature machinery vibration measurement. Version check: Confirm the legacy 612 part versus the manufacturer-identified 613 replacement, cable arrangement and applicable temperature/approval conditions.
CA202 144-202-000-205 is a legacy CA202 charge-output accelerometer for industrial vibration measurement. Newer CA202 specifications are provided as reference; confirm the offered cable assembly and calibration. Version check: Match the full 205 part number, integral cable and calibration; newer 206/216 ordering options do not establish the legacy cable length or approval.
CA202 144-202-000-215 is a legacy CA202 charge-output accelerometer for industrial vibration measurement. Newer CA202 specifications are provided as reference; confirm the offered cable assembly and calibration. Version check: Match the full 215 part number, integral cable and calibration; newer 206/216 ordering options do not establish the legacy cable length or approval.
IPC704 244-704-000-032 is a legacy IPC704 charge signal conditioner. The photographed unit carries CP237 calibration markings; later IPC704 parameters are provided as reference. Version check: Match the 032 PNR, CP237 calibration and actual HP/LP filters; later 042/511 specifications do not prove interchangeability.
IQS450 204-450-000-001 A2-B23-H10-I0 is a legacy proximity-system conditioner marked for 4 mV/µm, a 10 m measurement chain and VCL 140 target material. Later IQS450 parameters are provided as reference. Version check: Match the 001 AMP connector, B23 voltage sensitivity and 10 m calibrated chain; the newer 002 connector and current-output B24 option are different.
VM600 MPC4 200-510-041-021 is a legacy VM600 machinery-protection card. Later MPC4 parameters are provided as reference; retain the full 041-021 revision when matching the installed rack. Version check: Match the 041-021 revision, IOC4T pair and configuration software; newer output impedance, SIL claims and firmware compatibility do not automatically apply.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :