ISO 9001:2015 certified industrial automation spare parts supplier

Vibro Meter IPC704 244-704-000-032 Charge Signal Conditioner

IPC704 244-704-000-032 is a legacy IPC704 charge signal conditioner. The photographed unit carries CP237 calibration markings; later IPC704 parameters are provided as reference.

Version check: Match the 032 PNR, CP237 calibration and actual HP/LP filters; later 042/511 specifications do not prove interchangeability.

Download
  • Vibro Meter IPC704 244-704-000-032 Charge Signal Conditioner

    Vibro Meter IPC704 244-704-000-032 is a legacy conditioner in the IPC704 piezoelectric measurement family. It interfaces a sensor charge signal with monitoring electronics, using amplification and filtering appropriate to the configured measurement chain. The photographed unit carries an IPC704P-CP237 marking with a 7.5 pC/kPa input calibration and 50 µA/kPa output scaling. These visible calibration details help identify the pressure-measurement configuration, while the full 032 part number distinguishes it from later IPC704 hardware.

    Hardware specifications. The later IPC704 reference specifies an 18-30 V DC supply, 25 mA maximum consumption and configurable high-pass/low-pass filtering. Its current-output reference is a 12 mA standing current with a maximum ±5 mA dynamic component. These are newer 042/511 reference values, not independently confirmed ratings for the legacy 032. The actual filter cutoffs remain configuration-specific.

    Technical Specifications

    Parameter Specification

    Product Identity

    Complete legacy part number IPC704 244-704-000-032

    Functional Configuration

    Visible unit configuration IPC704P-CP237; manufacturer calibration marking
    Photographed input calibration 7.5 pC/kPa
    Photographed output scaling 50 µA/kPa
    Reference data scope IPC704 262-710 Version 12, later 042/511 variants
    Filtering Configured HP/LP cutoffs; exact installed settings require confirmation
    Dynamic-pressure chain Suitable GSI galvanic separation unit required
    Legacy equivalence 032-to-042/511 interchangeability not established

    Performance & Power

    Supply - newer reference 18-30 V DC; 25 mA maximum
    Current transmission - newer reference 12 mA ±0.5 mA standing current; ±5 mA peak dynamic component

    Environment

    Environmental protection with optional housing The optional ABA160 housing encloses one IPC704 and provides IP66 enclosure protection.

    Compatibility & Selection Guide

    System compatibility. Match the complete CP237 sensor and conditioner calibration, output scaling and monitor interface. A suitable GSI galvanic separation unit is required for dynamic-pressure measurement chains. The later 042 and 511 versions have different sensor-material applicability, so neither a common housing nor an IPC704 family name proves an equivalent replacement.

    Wiring & Installation Reference

    Use the newer manufacturer reference to compare the arrangement; confirm the legacy unit and complete measurement chain before applying connection or mounting details.

    Terminal reference

    Compare the marked I/P+, COM and +24 terminals with the installed measurement chain.

    The later current-output diagram uses +24V and COM; verify the actual legacy supply and connections before energising.

    View terminal reference (PDF)

    Mounting reference

    Compare the conditioner mounting holes and enclosure with the reference drawing.

    An external industrial enclosure is separate from the bare conditioner; confirm the actual installation protection.

    View mounting reference (PDF)

    Power and handling precautions

    • Dynamic-pressure sensors require a suitable GSI galvanic separation unit.

    • Do not transfer newer supply limits, approval conditions or filter selections to the legacy unit without checking applicability.

    Frequently Asked Questions

    What is IPC704 244-704-000-032 used for?

    It conditions piezoelectric sensor charge for monitoring electronics. The photographed unit is marked IPC704P-CP237 for a dynamic-pressure measurement configuration.

    Which calibration is visible on IPC704 244-704-000-032?

    The photographed calibration marking is 7.5 pC/kPa at the input and 50 µA/kPa at the output. Match the offered unit and sensor calibration before ordering.

    What supply is shown as reference for IPC704 244-704-000-032?

    Newer IPC704 versions use an 18-30 V DC supply and draw a maximum of 25 mA. Confirm the legacy 032 supply rating before applying that range.

    Is the output reference for IPC704 244-704-000-032 an ordinary 4-20 mA process signal?

    No. The later IPC704 current reference uses a 12 mA standing current with a maximum ±5 mA dynamic component. Use the actual configured scaling and a compatible dynamic measurement input.

    Does a pressure chain using IPC704 244-704-000-032 need galvanic separation?

    Yes. Use a suitable GSI galvanic separation unit for the dynamic-pressure transducer chain and verify the complete system configuration.

    Can the filter cutoffs of IPC704 244-704-000-032 be inferred from the base PNR?

    No. High-pass and low-pass settings are configurable. Confirm the offered unit settings and the required measurement band.

    Can IPC704 244-704-000-032 be replaced automatically by 244-704-000-042?

    No. The later 042 specifications are a reference here; they do not establish an unchanged configuration or direct replacement for 032.

    Can IPC704 244-704-000-032 be treated as the 244-704-000-511 variant?

    No. The 511 reference is intended for GaPO4 sensors. Match sensor material, calibration and the complete conditioner configuration.

    What should be supplied for a quotation for IPC704 244-704-000-032?

    Provide the full 032 PNR, CP237 sensor identification, input/output calibration, filter settings and the installed GSI/monitor arrangement so the offered unit can be compared.

    Manufacturer Documentation

    IPC704 244-704-000-032 Product Reference

    Actual legacy-model photograph and version checks, with selected newer manufacturer pages. Reference parameters are not proof of unchanged legacy ratings or interchangeability.

    PDF · 4 pages · 108.6 KB · Compiled by EWOLO CONTROL. 262-710 Version 12 (2017-11-08); newer revision reference.

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Vibro Meter IPC704 244-704-000-032

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.