CA134 144-134-000-613
CA134 integral-cable replacement variant
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier



CA134 144-134-000-612 is a passive 10 pC/g charge-output accelerometer for high-temperature machinery vibration measurement.
Version check: Confirm the legacy 612 part versus the manufacturer-identified 613 replacement, cable arrangement and applicable temperature/approval conditions.
Lifecycle status: Phase-out
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Vibro Meter CA134 144-134-000-612 is a charge-output accelerometer for vibration measurement at high machine-surface temperatures. Its compression-mode sensing element is internally insulated from a hermetically welded high-temperature nickel-alloy case. The 612 version uses an integral mineral-insulated cable, providing a sensor-and-cable assembly for demanding machinery measurement locations. A separate IPC70x charge conditioner converts the sensor output for the monitoring system. The complete 612 part number remains important because the manufacturer has announced its transition to the 613 replacement.
Hardware specifications. Nominal sensitivity is 10 pC/g, with a dynamic range of 0.001–500 g peak. Frequency response is ±5% from 0.5–3,500 Hz and within 10% from 3,500–6,000 Hz. The normal continuous operating range is −54 to +500 °C. The sensor is passive and uses an insulated two-pin charge output; special cryogenic ratings must not be assumed for this unit.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Complete part number | CA134 144-134-000-612 |
Functional Configuration |
|
| Sensor type | High-temperature piezoelectric accelerometer |
| Measuring element | Compression mode; internally case-insulated |
| Nominal sensitivity | 10 pC/g ±5% at 120 Hz, 5 g and reference temperature |
| Dynamic range | 0.001–500 g peak |
| Output | Two-pin charge output, insulated from case |
| Cable arrangement | Integral mineral-insulated cable, double-braid protection |
| Replacement identified | 144-134-000-613; verify complete application before substitution |
Performance & Power |
|
| Frequency response | 0.5–3,500 Hz ±5%; 3,500–6,000 Hz within 10% |
| Input power | None; passive charge sensor |
Environment |
|
| Normal continuous temperature | −54 to +500 °C; no cryogenic claim |
System compatibility. Use the CA134 with an appropriately configured IPC70x charge conditioner and a complete monitoring chain suitable for its sensitivity and operating environment. The manufacturer transition notice identifies PNR 144-134-000-613 as the replacement for 144-134-000-612, with delivery transition planned from October 2025. Confirm the offered part, cable arrangement and applicable approval conditions before accepting the newer version.
Use the CA134 integral-cable mechanical drawing and the specified mounting pattern.
Connect the insulated two-pin charge signal to a compatible IPC70x conditioner.
Keep the case and signal insulation arrangement consistent with the complete monitoring chain.
Use the three-hole CA134 mounting pattern.
Use three M4 × 16 screws and washers; specified tightening torque is 4 N·m.
Respect the 50 mm minimum bend radius and avoid force at the sensor cable exit.
Use the applicable hazardous-area certificate and complete chain conditions; do not infer every approval from a family heading.
The normal temperature range does not establish suitability for a special cryogenic application.
It measures dynamic acceleration for machinery vibration monitoring at high operating temperatures and sends a charge signal to a separate conditioner.
The nominal sensitivity is 10 pC/g with ±5% tolerance at the stated reference conditions. Use the individual calibration value when setting up the measurement chain.
No. It is a passive piezoelectric charge sensor. A suitable powered charge conditioner is required downstream.
The normal continuous range is −54 to +500 °C. A special cryogenic rating must not be assigned without evidence that the actual unit is that configuration.
Use an appropriate IPC70x charge conditioner, with input sensitivity and output scaling matched to the CA134 and the monitoring system.
The dynamic measurement range is 0.001–500 g peak. The low-frequency response also depends on the selected signal conditioner.
PNR 144-134-000-613 is the manufacturer-identified replacement for 144-134-000-612. Confirm the offered 613 configuration and installation approval conditions before substitution.
The manufacturer announced a staged transition from 612 to 613 and planned to confirm only 613 deliveries from October 2025. Verify availability of the requested legacy 612 part separately from the newer replacement.
Match the full PNR, sensor sensitivity, integral cable arrangement, temperature requirements and complete charge-conditioning chain. Check applicable hazardous-area certificate conditions where relevant.
Actual product photograph, application and replacement notes, with selected manufacturer pages covering specifications and connection or mechanical details.
PDF · 7 pages · 100.6 KB · Compiled by EWOLO CONTROL. DS 262-002 Version 7 (2025-05-16).
Preview Product Reference (PDF)CA134 integral-cable replacement variant
CA134 sensor-only version
Proximity transducer for relative shaft measurements
Reverse-mount proximity transducer
Matched proximity extension cable family
Proximity signal conditioner family
Configurable galvanic separation unit
Configurable piezoelectric signal conditioner
Piezoelectric signal conditioner in GSI127 chains
Velocity sensor with integrated electronics
IEPE piezoelectric vibration sensor
IEPE vibration sensor
Legacy IEPE vibration sensor
Legacy IEPE vibration sensor
Legacy IEPE vibration sensor
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
IQS450 204-450-000-002 A2-B24-H10-I1 is the 4 mm current-output IQS450 configuration for a 10 m TQ402/TQ412 proximity measurement chain. Version check: Confirm B24 current output, H10 total cable length, I1 mounting and target-material calibration; B23 voltage units are not interchangeable by appearance.
IPC704P-CP237 244-704-000-042 is a configured IPC704 charge-to-current conditioner for a CP237 dynamic-pressure measurement chain. Version check: Match the CP237 sensor calibration, output scaling and actual HP/LP cutoffs; 032, 042 and 511 suffixes are not automatic substitutes.
CA134 144-134-000-612 is a passive 10 pC/g charge-output accelerometer for high-temperature machinery vibration measurement. Version check: Confirm the legacy 612 part versus the manufacturer-identified 613 replacement, cable arrangement and applicable temperature/approval conditions.
CA202 144-202-000-205 is a legacy CA202 charge-output accelerometer for industrial vibration measurement. Newer CA202 specifications are provided as reference; confirm the offered cable assembly and calibration. Version check: Match the full 205 part number, integral cable and calibration; newer 206/216 ordering options do not establish the legacy cable length or approval.
CA202 144-202-000-215 is a legacy CA202 charge-output accelerometer for industrial vibration measurement. Newer CA202 specifications are provided as reference; confirm the offered cable assembly and calibration. Version check: Match the full 215 part number, integral cable and calibration; newer 206/216 ordering options do not establish the legacy cable length or approval.
IPC704 244-704-000-032 is a legacy IPC704 charge signal conditioner. The photographed unit carries CP237 calibration markings; later IPC704 parameters are provided as reference. Version check: Match the 032 PNR, CP237 calibration and actual HP/LP filters; later 042/511 specifications do not prove interchangeability.
IQS450 204-450-000-001 A2-B23-H10-I0 is a legacy proximity-system conditioner marked for 4 mV/µm, a 10 m measurement chain and VCL 140 target material. Later IQS450 parameters are provided as reference. Version check: Match the 001 AMP connector, B23 voltage sensitivity and 10 m calibrated chain; the newer 002 connector and current-output B24 option are different.
VM600 MPC4 200-510-041-021 is a legacy VM600 machinery-protection card. Later MPC4 parameters are provided as reference; retain the full 041-021 revision when matching the installed rack. Version check: Match the 041-021 revision, IOC4T pair and configuration software; newer output impedance, SIL claims and firmware compatibility do not automatically apply.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :