ISO 9001:2015 certified industrial automation spare parts supplier

Vibro Meter IPC704P-CP237 244-704-000-042 Dynamic Pressure Signal Conditioner

IPC704P-CP237 244-704-000-042 is a configured IPC704 charge-to-current conditioner for a CP237 dynamic-pressure measurement chain.

Version check: Match the CP237 sensor calibration, output scaling and actual HP/LP cutoffs; 032, 042 and 511 suffixes are not automatic substitutes.

Download
  • Vibro Meter IPC704P-CP237 244-704-000-042 Dynamic Pressure Signal Conditioner

    Vibro Meter IPC704P-CP237 244-704-000-042 is an IPC704 charge signal conditioner configured for a CP237 dynamic-pressure measurement chain. It converts the piezoelectric sensor charge into a signal suitable for the monitoring electronics, with high-pass and low-pass filtering appropriate to the configured measurement band. The photographed unit is identified for a 7.5 pC/kPa input and a 50 µA/kPa output. These configuration values distinguish this pressure-measurement unit from accelerometer and other pressure variants that share the IPC704 housing.

    Hardware specifications. The 244-704-000-042 version accepts sensors using standard piezoelectric materials. The supply requirement is 18–30 V DC with 25 mA maximum consumption. Current transmission has a nominal 12 mA standing current and a maximum ±5 mA dynamic signal. The bare conditioner has an IP40 enclosure and a −30 to +85 °C operating range; its fitted filter cutoffs must be confirmed from the individual configuration.

    Technical Specifications

    Parameter Specification

    Product Identity

    Complete unit identity IPC704P-CP237 244-704-000-042

    Functional Configuration

    Function Charge conditioning for CP237 dynamic pressure measurement
    Base version 244-704-000-042; standard piezoelectric materials
    Photographed input calibration 7.5 pC/kPa; unit nameplate
    Photographed output calibration 50 µA/kPa; unit nameplate
    Actual HP/LP filters Confirm the individual unit configuration; not inferred from the family range

    Performance & Power

    Supply 18–30 V DC; 25 mA maximum
    Current output standing value 12 mA ±0.5 mA
    Maximum dynamic current ±5 mA peak

    Environment

    Operating temperature −30 to +85 °C
    Bare enclosure protection IP40

    Compatibility & Selection Guide

    System compatibility. Use a suitable GSI galvanic separation unit in the dynamic-pressure chain. Match sensor sensitivity, current-versus-voltage output, scaling and both filter settings before replacement. The 042 version and the separately specified 511 version for GaPO4 sensors have different applicability. Do not assume an older 032 unit is interchangeable merely because its housing or CP237 label looks similar.

    Wiring & Installation Reference

    Use the current-output terminal markings and the applicable pressure-chain diagram.

    Current-output connections

    For two-wire current transmission, +24V is the positive connection and COM is the negative connection.

    Use the marked I/P+ and I/P− sensor inputs and retain the correct case/common arrangement shown in the manufacturer diagram.

    View terminal diagram (PDF)

    Mechanical mounting

    1. Confirm the enclosure

      The photographed bare unit is not an IP66 industrial enclosure.

    2. Secure the conditioner

      Use the manufacturer mounting pattern and the specified M4 fasteners.

    3. Verify the pressure chain

      Connect the suitable GSI separation unit and verify scaling and filter settings before operation.

    View mounting diagram

    Power and handling precautions

    • Dynamic-pressure sensors require a GSI galvanic separation unit.

    • Do not infer fitted filter frequencies, hazardous-area approval or an industrial enclosure from the base part number.

    Frequently Asked Questions

    What does IPC704P-CP237 244-704-000-042 do in a CP237 measurement chain?

    It converts the piezoelectric pressure sensor charge into a conditioned current signal for the monitoring electronics, with filtering defined by the configured unit.

    What supply does IPC704P-CP237 244-704-000-042 require?

    The IPC704 042 version requires 18–30 V DC with a maximum current consumption of 25 mA.

    Does IPC704P-CP237 244-704-000-042 provide a conventional 4–20 mA process signal?

    The IPC704 current transmission uses a nominal 12 mA standing current with a maximum ±5 mA dynamic signal. Match this dynamic measurement interface; do not assume a conventional 4–20 mA process scaling.

    Does IPC704P-CP237 244-704-000-042 require a galvanic separation unit for pressure measurement?

    Yes. Dynamic-pressure transducers must be used with a suitable GSI galvanic separation unit in the measurement chain.

    Can IPC704P-CP237 244-704-000-042 be ordered by the IPC704 family name alone?

    No. Match the full 042 part number, CP237 calibration, sensor sensitivity, output scaling and high-pass/low-pass filter settings.

    Can IPC704P-CP237 244-704-000-042 be treated as equivalent to the 244-704-000-511 version?

    No. The 042 version is intended for standard piezoelectric materials; the 511 version is intended for GaPO4 sensors. Their applicability and transfer ranges differ.

    Is the bare housing of IPC704P-CP237 244-704-000-042 waterproof?

    No. The bare conditioner is IP40. An appropriate industrial enclosure is a separate installation option and must not be assumed from the bare unit.

    What operating temperature applies to IPC704P-CP237 244-704-000-042?

    The IPC704 operating range is −30 to +85 °C. The complete installation must also satisfy its enclosure, environment and applicable approval conditions.

    Can the exact filter cutoffs of IPC704P-CP237 244-704-000-042 be inferred from its base part number?

    No. High-pass and low-pass frequencies are configurable ordering details. Confirm the individual unit settings and the required measurement band before replacement.

    Manufacturer Documentation

    IPC704P-CP237 244-704-000-042 Product Reference

    Actual product photograph, application and replacement notes, with selected manufacturer pages covering specifications and connection or mechanical details.

    PDF · 4 pages · 108.2 KB · Compiled by EWOLO CONTROL. 262-710 Version 12 (2017-11-08).

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Vibro Meter IPC704P-CP237 244-704-000-042

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.