CA134 144-134-000-613
CA134 integral-cable replacement variant
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier



IPC704P-CP237 244-704-000-042 is a configured IPC704 charge-to-current conditioner for a CP237 dynamic-pressure measurement chain.
Version check: Match the CP237 sensor calibration, output scaling and actual HP/LP cutoffs; 032, 042 and 511 suffixes are not automatic substitutes.
Lifecycle status: Unknown
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Vibro Meter IPC704P-CP237 244-704-000-042 is an IPC704 charge signal conditioner configured for a CP237 dynamic-pressure measurement chain. It converts the piezoelectric sensor charge into a signal suitable for the monitoring electronics, with high-pass and low-pass filtering appropriate to the configured measurement band. The photographed unit is identified for a 7.5 pC/kPa input and a 50 µA/kPa output. These configuration values distinguish this pressure-measurement unit from accelerometer and other pressure variants that share the IPC704 housing.
Hardware specifications. The 244-704-000-042 version accepts sensors using standard piezoelectric materials. The supply requirement is 18–30 V DC with 25 mA maximum consumption. Current transmission has a nominal 12 mA standing current and a maximum ±5 mA dynamic signal. The bare conditioner has an IP40 enclosure and a −30 to +85 °C operating range; its fitted filter cutoffs must be confirmed from the individual configuration.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Complete unit identity | IPC704P-CP237 244-704-000-042 |
Functional Configuration |
|
| Function | Charge conditioning for CP237 dynamic pressure measurement |
| Base version | 244-704-000-042; standard piezoelectric materials |
| Photographed input calibration | 7.5 pC/kPa; unit nameplate |
| Photographed output calibration | 50 µA/kPa; unit nameplate |
| Actual HP/LP filters | Confirm the individual unit configuration; not inferred from the family range |
Performance & Power |
|
| Supply | 18–30 V DC; 25 mA maximum |
| Current output standing value | 12 mA ±0.5 mA |
| Maximum dynamic current | ±5 mA peak |
Environment |
|
| Operating temperature | −30 to +85 °C |
| Bare enclosure protection | IP40 |
System compatibility. Use a suitable GSI galvanic separation unit in the dynamic-pressure chain. Match sensor sensitivity, current-versus-voltage output, scaling and both filter settings before replacement. The 042 version and the separately specified 511 version for GaPO4 sensors have different applicability. Do not assume an older 032 unit is interchangeable merely because its housing or CP237 label looks similar.
Use the current-output terminal markings and the applicable pressure-chain diagram.
For two-wire current transmission, +24V is the positive connection and COM is the negative connection.
Use the marked I/P+ and I/P− sensor inputs and retain the correct case/common arrangement shown in the manufacturer diagram.
The photographed bare unit is not an IP66 industrial enclosure.
Use the manufacturer mounting pattern and the specified M4 fasteners.
Connect the suitable GSI separation unit and verify scaling and filter settings before operation.
Dynamic-pressure sensors require a GSI galvanic separation unit.
Do not infer fitted filter frequencies, hazardous-area approval or an industrial enclosure from the base part number.
It converts the piezoelectric pressure sensor charge into a conditioned current signal for the monitoring electronics, with filtering defined by the configured unit.
The IPC704 042 version requires 18–30 V DC with a maximum current consumption of 25 mA.
The IPC704 current transmission uses a nominal 12 mA standing current with a maximum ±5 mA dynamic signal. Match this dynamic measurement interface; do not assume a conventional 4–20 mA process scaling.
Yes. Dynamic-pressure transducers must be used with a suitable GSI galvanic separation unit in the measurement chain.
No. Match the full 042 part number, CP237 calibration, sensor sensitivity, output scaling and high-pass/low-pass filter settings.
No. The 042 version is intended for standard piezoelectric materials; the 511 version is intended for GaPO4 sensors. Their applicability and transfer ranges differ.
No. The bare conditioner is IP40. An appropriate industrial enclosure is a separate installation option and must not be assumed from the bare unit.
The IPC704 operating range is −30 to +85 °C. The complete installation must also satisfy its enclosure, environment and applicable approval conditions.
No. High-pass and low-pass frequencies are configurable ordering details. Confirm the individual unit settings and the required measurement band before replacement.
Actual product photograph, application and replacement notes, with selected manufacturer pages covering specifications and connection or mechanical details.
PDF · 4 pages · 108.2 KB · Compiled by EWOLO CONTROL. 262-710 Version 12 (2017-11-08).
Preview Product Reference (PDF)CA134 integral-cable replacement variant
CA134 sensor-only version
Proximity transducer for relative shaft measurements
Reverse-mount proximity transducer
Matched proximity extension cable family
Proximity signal conditioner family
Configurable galvanic separation unit
Configurable piezoelectric signal conditioner
Piezoelectric signal conditioner in GSI127 chains
Velocity sensor with integrated electronics
IEPE piezoelectric vibration sensor
IEPE vibration sensor
Legacy IEPE vibration sensor
Legacy IEPE vibration sensor
Legacy IEPE vibration sensor
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
IQS450 204-450-000-002 A2-B24-H10-I1 is the 4 mm current-output IQS450 configuration for a 10 m TQ402/TQ412 proximity measurement chain. Version check: Confirm B24 current output, H10 total cable length, I1 mounting and target-material calibration; B23 voltage units are not interchangeable by appearance.
IPC704P-CP237 244-704-000-042 is a configured IPC704 charge-to-current conditioner for a CP237 dynamic-pressure measurement chain. Version check: Match the CP237 sensor calibration, output scaling and actual HP/LP cutoffs; 032, 042 and 511 suffixes are not automatic substitutes.
CA134 144-134-000-612 is a passive 10 pC/g charge-output accelerometer for high-temperature machinery vibration measurement. Version check: Confirm the legacy 612 part versus the manufacturer-identified 613 replacement, cable arrangement and applicable temperature/approval conditions.
CA202 144-202-000-205 is a legacy CA202 charge-output accelerometer for industrial vibration measurement. Newer CA202 specifications are provided as reference; confirm the offered cable assembly and calibration. Version check: Match the full 205 part number, integral cable and calibration; newer 206/216 ordering options do not establish the legacy cable length or approval.
CA202 144-202-000-215 is a legacy CA202 charge-output accelerometer for industrial vibration measurement. Newer CA202 specifications are provided as reference; confirm the offered cable assembly and calibration. Version check: Match the full 215 part number, integral cable and calibration; newer 206/216 ordering options do not establish the legacy cable length or approval.
IPC704 244-704-000-032 is a legacy IPC704 charge signal conditioner. The photographed unit carries CP237 calibration markings; later IPC704 parameters are provided as reference. Version check: Match the 032 PNR, CP237 calibration and actual HP/LP filters; later 042/511 specifications do not prove interchangeability.
IQS450 204-450-000-001 A2-B23-H10-I0 is a legacy proximity-system conditioner marked for 4 mV/µm, a 10 m measurement chain and VCL 140 target material. Later IQS450 parameters are provided as reference. Version check: Match the 001 AMP connector, B23 voltage sensitivity and 10 m calibrated chain; the newer 002 connector and current-output B24 option are different.
VM600 MPC4 200-510-041-021 is a legacy VM600 machinery-protection card. Later MPC4 parameters are provided as reference; retain the full 041-021 revision when matching the installed rack. Version check: Match the 041-021 revision, IOC4T pair and configuration software; newer output impedance, SIL claims and firmware compatibility do not automatically apply.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :