ISO 9001:2015 certified industrial automation spare parts supplier

Vibro Meter CA202 144-202-000-205 Piezoelectric Accelerometer

CA202 144-202-000-205 is a legacy CA202 charge-output accelerometer for industrial vibration measurement. Newer CA202 specifications are provided as reference; confirm the offered cable assembly and calibration.

Version check: Match the full 205 part number, integral cable and calibration; newer 206/216 ordering options do not establish the legacy cable length or approval.

Download
  • Vibro Meter CA202 144-202-000-205 Piezoelectric Accelerometer

    Vibro Meter CA202 144-202-000-205 is a piezoelectric accelerometer in the CA202 industrial vibration-measurement family. It converts dynamic acceleration into a charge signal for a separate signal conditioner and machinery-monitoring system. The family uses a symmetrical shear-mode sensing element with internal case insulation, a stainless-steel housing and an integral protected cable. The actual photographs identify the legacy 205 assembly, helping maintenance buyers match an installed sensor without confusing it with a newer cable variant.

    Hardware specifications. Newer CA202 reference values are 100 pC/g nominal sensitivity, a 0.01-400 g peak dynamic range and a 0.5-6,000 Hz response within ±5%. The newer continuous limits are -55 to +260 °C for the sensor and -55 to +200 °C for its cable. These values describe the current documented family; the legacy 205 ratings and cable length are not independently confirmed by that ordering table.

    Technical Specifications

    Parameter Specification

    Product Identity

    Complete legacy part number CA202 144-202-000-205
    Product family CA202 piezoelectric charge-output accelerometer

    Functional Configuration

    Reference data scope Newer CA202, DS 262-020 Version 10; legacy 205 applicability requires confirmation
    Nominal sensitivity - newer reference 100 pC/g ±5% at stated reference conditions
    Dynamic range - newer reference 0.01-400 g peak
    Signal principle Passive piezoelectric charge output; separate charge converter
    Legacy cable length and approvals Confirm the offered 205 assembly; not inferred from newer 206/216 variants

    Performance & Power

    Frequency response - newer reference 0.5-6,000 Hz ±5%; lower cutoff depends on conditioner

    Environment

    Sensor temperature - newer reference -55 to +260 °C continuous
    Cable temperature - newer reference -55 to +200 °C continuous

    Compatibility & Selection Guide

    System compatibility. The measurement chain uses a charge converter such as an appropriately configured IPC70x. Match the offered sensor calibration, cable arrangement, conditioner scaling and monitoring requirements. A newer CA202 part number is not an automatic substitute for this legacy assembly, and current Ex approvals must not be transferred to it without the applicable certificate and unit marking.

    Wiring & Installation Reference

    Use the newer manufacturer reference to compare the arrangement; confirm the legacy unit and complete measurement chain before applying connection or mounting details.

    Charge-output reference

    Keep the sensor charge signal separate from an ordinary powered voltage or 4-20 mA interface.

    Compare the lead identification with the current drawing and the actual legacy assembly before connection.

    View connection reference (PDF)

    Sensor and cable reference

    Compare the mounting footprint and cable exit with the actual sensor.

    The newer drawing and mounting details are a comparison reference; confirm their applicability before applying torque or modifying the installation.

    View mounting reference (PDF)

    Power and handling precautions

    • Confirm the actual sensor and cable temperature limits separately.

    • Apply only hazardous-area certificates that explicitly cover the offered unit and measurement chain.

    Frequently Asked Questions

    What does CA202 144-202-000-205 measure?

    It is a CA202 piezoelectric acceleration sensor used in industrial machinery vibration measurements, with charge conversion provided by a separate conditioner.

    Does CA202 144-202-000-205 connect directly to a standard 4-20 mA input?

    No. A charge-output accelerometer needs a suitable charge converter. Choose the converter output and scaling for the monitoring input.

    What sensitivity should be used when selecting CA202 144-202-000-205?

    Use the calibration supplied for the offered sensor. The newer CA202 family reference is 100 pC/g nominal; confirm the legacy unit calibration before setting the conditioner.

    What frequency range is used as the reference for CA202 144-202-000-205?

    The newer CA202 reference is 0.5-6,000 Hz within ±5%. The lower cutoff also depends on the conditioner; this is not independent confirmation of the legacy assembly bandwidth.

    Can the sensor and cable of CA202 144-202-000-205 use the same temperature limit?

    Do not assume so. The newer family has separate continuous limits of +260 °C for the sensor and +200 °C for the cable. Verify the limits applicable to the offered legacy assembly.

    What cable length comes with CA202 144-202-000-205?

    The legacy cable length remains to be confirmed from the offered assembly or its original ordering record. Do not infer it from the newer 206 or 216 suffix.

    Is CA202 144-202-000-205 automatically approved for hazardous areas?

    No. Match the exact unit marking, certificate scope and complete installation conditions. A family datasheet containing Ex options does not certify every legacy assembly.

    Which conditioner should be matched to CA202 144-202-000-205?

    Use a charge-input conditioner with sensitivity and output scaling appropriate to the sensor and monitor. An IPC70x is the family reference; verify its full configuration and measurement-chain requirements.

    What should be checked before replacing CA202 144-202-000-205?

    Compare the full part number, actual sensor calibration, integral cable length and termination, temperature requirements and measurement-chain configuration. Do not treat a similar housing as interchangeability proof.

    Manufacturer Documentation

    CA202 144-202-000-205 Product Reference

    Actual legacy-model photograph and version checks, with selected newer manufacturer pages. Reference parameters are not proof of unchanged legacy ratings or interchangeability.

    PDF · 5 pages · 81.3 KB · Compiled by EWOLO CONTROL. DS 262-020 Version 10 (2024-01-10); newer revision reference.

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Vibro Meter CA202 144-202-000-205

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.