Yokogawa AAI143-H50 is a 16-channel isolated 4–20 mA input module for CENTUM FIO. It supports HART communication, per-channel two-wire or four-wire transmitter selection and dual-redundant configurations.
Version check: Confirm -H50, hardware Style, two-wire/four-wire channel settings and the existing single or dual terminal adapter.
Lifecycle status: Unknown
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Yokogawa AAI143-H50 connects sixteen 4–20 mA transmitter signals to a CENTUM FIO control system, providing a compact input interface for process measurement. Its HART capability combines analog measurement with digital communication to compatible instruments. Each channel can be configured for a two-wire or four-wire transmitter using its setting pin, and the module supports dual-redundant arrangements. AAI143-H50 is an input module, so it should be distinguished from similarly named output modules when ordering replacement cards.
Hardware specifications. AAI143-H50 has 16 isolated inputs, ±16 µA accuracy and a 10 ms data update period. The allowable input current is 24 mA. Transmitter supply is at least 19 V at 20 mA, with a 25 mA output current limit. Maximum consumption is 230 mA at 5 V DC and 540 mA at 24 V DC. Module dimensions are 32.8 × 130 × 107.5 mm (W × H × D).
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer | Yokogawa |
| Complete model | AAI143-H50 |
| Dimensions (W × H × D) | 32.8 × 130 × 107.5 mm; module only |
Functional Configuration |
|
| Function | Analog input with HART communication |
| Input channels | 16; isolated input module |
| Input signal | 4–20 mA DC |
| Transmitter selection | Two-wire or four-wire; setting pin per channel |
Performance & Power |
|
| Allowable input current | 24 mA |
| Accuracy | ±16 µA |
| Data update period | 10 ms |
| Transmitter supply | ≥19 V at 20 mA; current limit 25 mA |
| Maximum current consumption | 230 mA at 5 V DC; 540 mA at 24 V DC |
Environment |
|
| Protection option | Standard version without explosion protection |
System compatibility. AAI143-H50 belongs to the CENTUM FIO platform. The Release 6 environment includes AFV30/AFV40 field control stations, VP6F1700 control functions and VP6E5100 engineering. The -H50 code selects HART, no explosion protection and the basic type. Replacement checks must include system release, hardware Style, transmitter configuration and the exact terminal-adapter option.
Use the matching Yokogawa system and connection instructions for the installed assembly. The checks below are specific to AAI143-H50.
| Item | Requirement | Check |
|---|---|---|
| Signal | 4–20 mA DC | Allowable input current 24 mA |
| Channel setting | Two-wire / four-wire | Set each channel for its transmitter |
| Supply budget | ≥19 V at 20 mA | Include external wiring drop |
Match the field control unit, node type, complete module code and existing configuration before replacement.
Use the specified terminal/cable interface and check the module envelope against the installed assembly.
Confirm -H50, hardware Style, two-wire/four-wire channel settings and the existing single or dual terminal adapter.
Use an isolation barrier when an intrinsically safe interface is required; do not connect a Zener barrier.
Confirm each transmitter setting and the selected terminal adapter before applying field power.
It is a 16-channel 4–20 mA analog input module. It receives transmitter signals; it is not the corresponding analog output module.
Yes. H identifies the HART version. The -S version must not be treated as equivalent when digital HART communication is required.
Yes. A setting pin selects the transmitter arrangement separately for each channel. Match these settings to the connected instruments.
The nominal signal is 4–20 mA DC and the allowable input current is 24 mA. Do not use an output-module load specification as an input limit.
Input accuracy is ±16 µA and the data update period is 10 ms. Overall measurement performance also depends on the field instrument and installation.
It provides at least 19 V at 20 mA and no more than 25.5 V at zero current. Its output current limit is 25 mA; allow for voltage lost in the field wiring.
No. Use an isolation barrier for intrinsically safe applications. A Zener barrier must not be connected to AAI143-H50.
Yes. Use the matching redundancy arrangement and terminal hardware. The available terminal options include ATA4S-00 for single and ATA4D-00 for dual pressure-clamp termination.
Match the complete -H50 code, hardware Style, installed system release, channel transmitter settings and terminal-adapter option. A matching front connector alone does not establish interchangeability.
Product photograph, model identification and compatibility notes, followed by selected Yokogawa pages covering specifications, dimensions and ordering codes.
PDF · 5 pages · 106.2 KB · Compiled by EWOLO CONTROL. Manufacturer extracts: GS 33J60F60-01EN, 6th Edition, 2017-03-20.
Preview Product Reference (PDF)8-Channel HART Analog Input Module
16-Channel HART Analog Output Module
8-Input 8-Output HART Analog I/O Module
8-Channel Isolated Pulse Input Module
32-Channel 24V DC Digital Input Module
32-Channel 24V DC Digital Output Module
2-Port RS-422 RS-485 Communication Module
1-Port ESB Bus Coupler Module
2-Port ESB Bus Coupler Module
16-channel non-isolated 4–20 mA input module
16-channel non-isolated 1–5 V input module
16-channel HART 1–5 V / 4–20 mA input module
4-input/4-output isolated-channel HART module
16-channel isolated TC/mV input module
16-channel isolated RTD/POT input module
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Yokogawa AAI543-H50 is a 16-channel isolated 4–20 mA output module for CENTUM FIO. It supports HART communication and standard-response switching in a dual-redundant configuration. Version check: Match the -H50 standard switchover response, hardware Style and terminal option; a redundant pair must use the same response class.
Yokogawa AAI841-H00 is a non-isolated FIO module with eight 4–20 mA inputs and eight 4–20 mA outputs. It supports up to eight loops, HART communication and dual-redundant configurations. Version check: Confirm the legacy -H00 code, hardware Style, node and terminal option; HART in an ER-bus remote node requires EB401 Rev. 2 or later.
Yokogawa AAP135-S50 is an eight-channel isolated pulse input module for CENTUM FIO. It accepts contact, voltage-pulse and current-pulse signals, with frequency limits determined by the selected signal and redundancy configuration. Version check: Match pulse source, frequency, transmitter supply and redundancy mode; dry-contact limits are lower than the 10 kHz electronic-pulse limit.
Yokogawa ADV151-P60 is a 32-channel 24 V DC digital input module for CENTUM FIO. The P version supports pushbutton input, and suffix 6 provides input-status display without explosion protection. Version check: Confirm -P60 pushbutton capability, status display, hardware Style and input polarity; do not substitute an output or SOE-capture version.
Yokogawa ADV551-P60 is a 32-channel current-sink transistor output module for CENTUM FIO. It supports status, pulse-width and time-proportioning output patterns with output-status display. Version check: Match -P60, sink-output load and configured point-mode pattern; check paired-channel and redundancy restrictions before replacement.
Yokogawa ALR121-S50 is a two-port RS-422/RS-485 serial communication module for CENTUM N-IO/FIO systems. It exchanges subsystem data with the FCS using supported functions such as Modbus RTU and FA-M3 communication. Version check: Confirm RS-422/RS-485, the common protocol selected for both ports, baud rate, data mapping and the installed redundancy arrangement.
Yokogawa EC401-50 is a one-port ESB bus coupler for CENTUM N-IO/FIO. It links the field control unit to supported ESB nodes at 128 Mbps and supports single or dual-redundant module arrangements. Version check: For a CP471 system, require EC401 Style S3 or later; also match the one-port ESB topology, node types and redundancy arrangement.
Yokogawa EC402-50 is a two-port ESB bus coupler for CENTUM N-IO/FIO. Its upper and lower ESB connections link supported field control units to I/O nodes at 128 Mbps. Version check: Match the two-port ESB topology and system release; the 12-nodes-per-port exception applies only to the specified A2FV50 star configuration.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :