ISO 9001:2015 certified industrial automation spare parts supplier

SIGNAL INTERFACES & INDUSTRIAL COMMUNICATION

I/O & Communication Modules

Browse input/output modules, communication interfaces and related system components. Confirm the complete part number, signal type, connection arrangement and installed platform before selecting a replacement or additional module.

Send your complete part numbers, quantities and required delivery date for pricing, availability and estimated dispatch. You can combine multiple items in one enquiry.

Industrial input and output modules
  • IS220PDIAH1A discrete front view
    GE IS220PDIAH1A 24-Channel Discrete Input I/O Pack
    GE IS220PDIAH1A is a Mark VIe discrete input I/O pack that brings up to 24 contact inputs from a compatible terminal board onto the I/O Ethernet network. It is intended for monitoring discrete field states in the configured control system. Version check: Match the contact wetting voltage, terminal-board code and required simplex/dual/TMR arrangement; input channels are not individually isolated.
    Read More
  • IS220PAOCH1A analog front view
    GE IS220PAOCH1A 8-Channel Analog Output I/O Pack
    GE IS220PAOCH1A is the Mark VIe analog output I/O pack for eight simplex current-loop outputs. It links the I/O Ethernet network to a compatible analog-output terminal board for control signals to field equipment. Version check: Confirm the TBAO/ STAO terminal-board revision and simplex output configuration; earlier TBAOH1A/H1B boards are not equivalent to TBAOH1C.
    Read More
  • 8C-PDODA1 51454472-175 front module view
    Honeywell 8C-PDODA1 51454472-175 32-Channel 24 VDC Digital Output Module
    Honeywell 8C-PDODA1 51454472-175 is a coated Series 8 module with 32 bussed 24 VDC digital outputs. It controls discrete process equipment, solenoid valves or interposing relays, subject to its 100 mA per-channel and 3.2 A per-module load limits. Version check: Confirm the installed 8C-TDODA1 or 8C-TDODB1 IOTA, shared-return field-power arrangement and 100 mA channel load limit; use the separate relay extension when dry contacts are required.
    Read More
  • 8C-PDISA1 51454471-275 front module view
    Honeywell 8C-PDISA1 51454471-275 32-Channel Sequence of Events Input Module
    Honeywell 8C-PDISA1 51454471-275 is a coated Series 8 sequence-of-events input module for 32 discrete 24 VDC signals. It supports 1 ms event resolution, normal or low-latency PV scanning and optional redundancy. Version check: Confirm the 8C-PDISA1 SOE model, the required normal/SOE/low-latency mode and installed 8C-TDILA1 or 8C-TDILB1 IOTA; 1 ms event resolution is not the PV scan rate.
    Read More
  • 8C-PDILA1 51454471-175 front module view
    Honeywell 8C-PDILA1 51454471-175 32-Channel 24 VDC Digital Input Module
    Honeywell 8C-PDILA1 51454471-175 is the coated Series 8 digital input module for 32 discrete 24 VDC signals. It supports internal or external field power, direct or reverse indication and optional redundancy for the Series 8 I/O platform. Version check: Confirm standard DI rather than SOE or pulse accumulation, the installed 8C-TDILA1 or 8C-TDILB1 IOTA, and internal or external field power before replacing 8C-PDILA1.
    Read More
  • 8C-PAOHA1 51454469-275 front module view
    Honeywell 8C-PAOHA1 51454469-275 16-Channel HART Analog Output Module
    Honeywell 8C-PAOHA1 51454469-275 is a Series 8 analog output module for 16 current-output loops. It provides 4–20 mA outputs with HART support for actuators and recording or indicating devices, with optional redundancy and per-channel safe-state configuration. Version check: Confirm the 8C-PAOHA1 label, HART output requirement, installed 8C-TAOXA1 or 8C-TAOXB1 IOTA and channel FAILOPT settings before replacement.
    Read More
  • CC-PUIO31 51454220-176 front module view
    Honeywell CC-PUIO31 51454220-176 Series C Universal I/O Module-2
    Honeywell CC-PUIO31 51454220-176 is the 32-channel Series C Universal I/O Module-2 for Experion PKS. It combines configurable analog and digital channels with HART 7, sequence-of-events digital inputs and pulse inputs on any four channels. Version check: Confirm Experion R432 or later, the CC-TUIO31 or CC-TUIO41 IOTA and the configured channel functions before replacing this UIO-2 module.
    Read More
  • CC-PUIO01 51454205-175 front view
    Honeywell CC-PUIO01 51454205-175 Series C Universal I/O Module
    Honeywell CC-PUIO01 51454205-175 is a 32-channel Series C Universal I/O module for Experion PKS process control. Each channel can be configured for analog input, analog output, digital input or digital output, allowing mixed field signals on one module. Version check: Confirm the CC-TUIO01 or CC-TUIO11 IOTA, redundancy arrangement, configured channel types and Experion release before replacing this UIO module.
    Read More
  • CC-PDIL01 51405040-176 front view
    Honeywell CC-PDIL01 51405040-176 24V Digital Input Module
    Honeywell CC-PDIL01 51405040-176 is a 32-channel Series C 24V digital input IOM for Experion PKS. Verify the matching IOTA and field-power configuration. Version check: Confirm the complete CC-PDIL01 51405040-176 part number, matching IOTA and redundancy configuration before ordering.
    Read More
  • CC-PAOH51 51410070-275 front view
    Honeywell CC-PAOH51 51410070-275 HART Analog Output Module
    Honeywell CC-PAOH51 51410070-275 is a Series C high-level analog output module for Experion PKS. It supplies 16 current-output channels for actuators and recording or indicating devices, with HART configuration and status support. Version check: Match the complete module code, CC-TAOX51/CC-TAOX61 termination assembly and installed system configuration. Other Series C output modules use different IOTAs and are not assumed to be interchangeable.
    Read More
  • CC-PAIN01 51410069-176 front view
    Honeywell CC-PAIN01 51410069-176 Analog Input Module
    Honeywell CC-PAIN01 51410069-176 is a Series C high-level analog input module for Experion PKS. It accepts 16 single-ended 4–20 mA process signals through a matching non-HART termination assembly. Version check: Confirm the complete module code, installed IOTA and system configuration before ordering. CC-PAIN01 is the non-HART current-input model; HART and universal I/O models are separate products.
    Read More
  • AX522 1SAP250000R0001 front view
    ABB AX522 1SAP250000R0001 Analog Input/Output Module
    ABB AX522 1SAP250000R0001 combines eight analog inputs and eight analog outputs for AC500 systems using S500 I/O. It supports voltage, current and resistance-temperature inputs; current output is available on channels 0 to 3. Version check: Confirm the complete ordering code, configured signals and terminal unit for your application. AX522-XC is a separate variant.
    Read More
  • 126648-01 Keyphasor I/O Connector Front
    Bently Nevada 126648-01 Keyphasor External I/O Module
    Bently Nevada 126648-01 is the non-isolated Keyphasor I/O module with external terminations for the 3500/25 family. The required external termination block and cable are separate items. Version check: Confirm 126648-01, non-isolated inputs and external terminations against the installed 3500/25 assembly before ordering.
    Read More
  • 125800-01 Keyphasor I/O Terminal Front
    Bently Nevada 125800-01 Keyphasor I/O Module
    Bently Nevada 125800-01 is the non-isolated, internal-termination Keyphasor I/O spare for the 3500/25 family. It connects the field signal side of a compatible Keyphasor monitoring assembly. Version check: Confirm 125800-01, non-isolated inputs and internal terminations against the installed 3500/25 assembly before ordering.
    Read More
  • 136711-01 Temperature Barrier I/O Front
    Bently Nevada 136711-01 RTD/TC Internal Barrier I/O Module
    Bently Nevada 136711-01 is the non-isolated RTD/TC I/O module with internal barriers and internal terminations for the 3500/60 temperature monitor. The barrier-specific sensor and earthing requirements apply. Version check: Confirm 136711-01 for the 3500/60 non-isolated RTD/TC internal-barrier arrangement; the 3500/61 spare has a different part number.
    Read More
  • 125720-01 Relay I/O Terminal Front
    Bently Nevada 125720-01 Four-Channel Relay Output Module
    Bently Nevada 125720-01 is the four-channel relay output spare listed for the 3500/32M family. The current manufacturer datasheet identifies this exact part as available for repair only. Version check: Confirm 125720-01 and the installed 3500/32M relay assembly. The manufacturer spare entry lists this part as available for repair only.
    Read More
  • 136703-01 Tachometer Barrier I/O Front
    Bently Nevada 136703-01 Internal Barrier I/O Module
    Bently Nevada 136703-01 is the discrete internal-barrier I/O module with internal terminations listed for the 3500/50M tachometer. Internal-barrier system requirements apply, including the permitted transducer types. Version check: Confirm 136703-01 and the internal-barrier tachometer configuration; this barrier option does not support magnetic pickups.
    Read More
  • 133442-01 Tachometer I/O Terminal Front
    Bently Nevada 133442-01 Tachometer I/O Module
    Bently Nevada 133442-01 is the internal-termination I/O module listed for the 3500/50M tachometer assembly. It is the standard rear I/O option, distinct from the internal-barrier and external-termination variants. Version check: Confirm 133442-01, internal terminations and the installed 3500/50M tachometer configuration before ordering.
    Read More
  • 125680-01 Proximitor I/O Terminal Front
    Bently Nevada 125680-01 Proximitor I/O Module
    Bently Nevada 125680-01 is the internal-termination Proximitor I/O module specified for the 3500/40M monitor. It provides the rear I/O connection for a compatible proximity-transducer monitoring channel assembly. Version check: Confirm 125680-01 and the internal-termination I/O arrangement against the installed 3500/40M assembly before ordering.
    Read More
  • 128229-01 Prox Seismic module terminal side
    Bently Nevada 128229-01 Prox/Seismic I/O Module with Internal Terminations
    Bently Nevada 128229-01 is the internal-termination Prox/Seismic I/O module for a 3500/42M monitoring assembly. It provides the field connections at the rear of the 3500 rack. The official I/O selection table lists Seismoprobe for this option. Version check: Confirm the full I/O part number and installed transducer type. Prox/Accel and Velomitor are supported but not recommended for 128229-01.
    Read More

Request a quote

Have a part number?
Let us check it.

Send the exact model and quantity, plus a nameplate photo or parts list if available.

Dedicated RFQ contact
Sandy Lin Sales & General Manager

Send the complete model and quantity for review.

What happens next

  1. Email confirmation
  2. Requirement review
  3. Written quotation

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.