Honeywell CC-PUIO31 51454220-176 Series C Universal I/O Module-2

Honeywell CC-PUIO31 51454220-176 is the 32-channel Series C Universal I/O Module-2 for Experion PKS. It combines configurable analog and digital channels with HART 7, sequence-of-events digital inputs and pulse inputs on any four channels.

Version check: Confirm Experion R432 or later, the CC-TUIO31 or CC-TUIO41 IOTA and the configured channel functions before replacing this UIO-2 module.

Download
  • Honeywell CC-PUIO31 51454220-176 Series C UIO-2

    Honeywell CC-PUIO31 51454220-176 is the Series C Universal I/O Module-2 for combining different process signal functions in an Experion PKS system. Its 32 configurable channels support analog and digital input or output, with HART 7 communication and a HART modem per channel for analog-device data. Digital inputs can provide 1 ms sequence-of-events resolution, and any four channels can be assigned pulse-input functions. This combination serves applications that need process measurements, control outputs and time-tagged equipment states, with open-wire detection and configurable output failure behavior supporting channel supervision.

    Hardware specifications. The CC-PUIO31 51454220-176 provides 16-bit analog inputs at 0–20 mA or 4–20 mA with a 10 ms input scan, and 12-bit 4–20 mA analog outputs. HART 7 is supported with a modem per channel. Digital inputs support 1 ms sequence-of-events resolution, and any four channels can accept pulses up to 15 kHz. Sourcing digital outputs are rated up to 0.5 A per channel and 9 A per module, subject to channel loading and thermal conditions.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer Honeywell
    Model CC-PUIO31 51454220-176
    Product type Series C Universal I/O Module-2 (UIO-2)

    Functional Configuration

    Channel capacity 32 configurable I/O channels; AI, AO, DI or DO
    Analog input 0–20 mA or 4–20 mA; 2-, 3- or 4-wire current devices
    Analog output 4–20 mA; 12-bit resolution
    HART HART 7 on analog I/O; HART modem per channel
    Digital input SOE 1 ms resolution; 20 ms PV scan
    Pulse input Any four channels; 0–15 kHz; minimum pulse width 25 µs
    Digital output Solid-state sourcing; 0.5 A maximum per channel; 9 A maximum per module, subject to configuration and ambient temperature
    Non-redundant IOTA CC-TUIO31, nominal 9 in
    Redundant IOTA CC-TUIO41, nominal 12 in
    Configuration environment Experion Control Builder, Series C I/O library (UIO-2); introduced with R432

    Performance & Power

    Analog input conversion / scan 16 bit; 10 ms input scan
    Power arrangement Module power and field connections via the matching IOTA; Series C IOTA power supplied from a 24 VDC carrier bus

    Environment

    Module ambient temperature −40 to +70 °C; apply the UIO-2 high-temperature-limit calculation

    Compatibility & Selection Guide

    System compatibility. Honeywell introduced CC-PUIO31 with Experion R432. Configure the UIO-2 module and its AI, AO, DI or DO channel blocks in the Series C I/O library of Experion Control Builder. The specified IOTAs are CC-TUIO31 for non-redundant use and CC-TUIO41 for redundant use. Confirm the installed Experion release, redundancy arrangement, channel settings and temperature-alarm calculation before selecting CC-PUIO31 51454220-176.

    Wiring & Installation Reference

    Use the wiring instructions for the exact UIO-2 IOTA and configured signal type. The summary below does not replace the manufacturer's complete wiring and safety procedures.

    Field connections

    Connection Use Check
    TB1 Channels 1–16 Match each channel's + and − screw terminals
    TB2 Channels 17–32 Match the configured AI, AO, DI or DO function
    TB3 (redundant IOTA) +24 V terminals Follow the exact IOTA connection drawing

    Analog input. Use the documented 2-, 3- or 4-wire current-transmitter arrangement; check the transmitter power reference and allowable field-loop resistance.

    Digital input. Fit the specified field resistor arrangement near the switch when open-wire detection is enabled.

    Digital output. Check per-channel current, module total and thermal limits. Do not apply the module's maximum current rating to every channel simultaneously.

    View terminal assignments (PDF)

    Mounting and configuration

    1. Confirm the assembly

      Identify CC-PUIO31 and the installed CC-TUIO31 or CC-TUIO41 IOTA. Confirm redundancy and the saved channel configuration.

    2. Prepare the installation

      Turn off all power at the installation location before the installation procedure. Mount and ground the correct IOTA/carrier assembly as described in the user guide.

    3. Fit the module

      Mate the module correctly with the IOTA connector and secure the specified screws. Use a #2 Phillips screwdriver for the long gray plastic screw; do not use a battery-powered screwdriver.

    4. Check loading and temperature

      Mount the module upright for natural-convection cooling and complete the applicable UIO thermal calculation before putting configured channels into service.

    View mounting and safety reference (PDF)

    Power and handling precautions

    • Correct signal type. UIO analog inputs measure current; do not connect a voltage, thermocouple, RTD or NAMUR signal directly as though it were a supported current loop.

    • Field load and diagnostics. Channel settings, open-wire monitoring components and actual load must match. Follow all power-isolation, grounding and installation requirements in the manufacturer's complete guide.

    • Thermal limits. The published −40 to +70 °C module ambient range does not permit unrestricted output loading. Apply the current configuration and inlet-air temperature to the manufacturer's thermal calculation.

    Frequently Asked Questions

    What does UIO-2 mean for Honeywell CC-PUIO31 51454220-176?

    UIO-2 is Honeywell's Universal I/O Module-2. It has 32 configurable channels and uses CC-TUIO31/41 IOTAs. Its documented functions include HART 7, 1 ms digital-input SOE and pulse input on any four channels.

    Which Experion release supports Honeywell CC-PUIO31 51454220-176?

    The user guide states that CC-PUIO31 was introduced with Experion R432. Confirm the installed release, firmware requirements and project configuration before selecting a replacement; do not assume compatibility with earlier releases.

    Which IOTA matches Honeywell CC-PUIO31 51454220-176?

    Use the documented CC-TUIO31 non-redundant IOTA or CC-TUIO41 redundant IOTA. A non-redundant UIO-2 IOTA accepts one UIO-2 module. Verify the existing IOTA and redundancy arrangement.

    Can Honeywell CC-PUIO31 51454220-176 replace a CC-PUIO01 without other checks?

    No direct substitution is established by the reviewed documents. CC-PUIO01 uses CC-TUIO01/11, whereas CC-PUIO31 uses CC-TUIO31/41 and requires the applicable Experion release. Review the complete module/IOTA configuration and channel settings before changing models.

    How many pulse inputs can Honeywell CC-PUIO31 51454220-176 provide?

    Any four channels can be configured as pulse inputs. The specification gives a frequency range of 0–15 kHz and a minimum pulse width of 25 µs.

    Does Honeywell CC-PUIO31 51454220-176 support direct temperature-sensor or voltage input?

    The UIO-2 analog-input function measures current. Honeywell lists voltage signals, thermocouples, RTDs and NAMUR devices as not directly supported by that function; use a compatible conditioning arrangement where required.

    Can the digital outputs on Honeywell CC-PUIO31 51454220-176 all run at full current?

    The module has a 0.5 A per-channel limit and a 9 A aggregate limit. The allowed channel mix and current also depend on operating temperature. Use the UIO-2 high-temperature-limit calculation and the manufacturer's channel-loading guidance.

    Will changing an analog-output channel on Honeywell CC-PUIO31 51454220-176 to HART disturb its output?

    The specification says that changing a channel from non-HART to HART while its output remains energized may disturb the output for up to 65 ms during reload. Changing from HART to non-HART does not produce that disturbance. Plan configuration changes with the process requirements in mind.

    Does Honeywell CC-PUIO31 51454220-176 support open-wire detection on digital inputs?

    Yes. When DI open-wire detection is enabled, the field circuit requires the specified resistor arrangement close to the contact. Use the UIO-2 wiring drawing and matching channel configuration.

    Manufacturer Documentation

    CC-PUIO31 51454220-176 Product Reference

    Product identification and selected Honeywell UIO-2 specifications, terminal connections, installation precautions and thermal limits.

    PDF · 12 pages · 95.7 KB · Compiled by EWOLO CONTROL. Experion Series-C I/O Specification EP03-490-520, R520, December 2021, v1.5; Series C I/O User's Guide EPDOC-X126-en-A, November 2019.

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Honeywell CC-PUIO31 51454220-176

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.