8C-TDODA1
Series 8 nonredundant digital output IOTA
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier



Honeywell 8C-PDODA1 51454472-175 is a coated Series 8 module with 32 bussed 24 VDC digital outputs. It controls discrete process equipment, solenoid valves or interposing relays, subject to its 100 mA per-channel and 3.2 A per-module load limits.
Version check: Confirm the installed 8C-TDODA1 or 8C-TDODB1 IOTA, shared-return field-power arrangement and 100 mA channel load limit; use the separate relay extension when dry contacts are required.
Lifecycle status: Unknown
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Honeywell 8C-PDODA1 51454472-175 is the coated Series 8 bussed digital output module for issuing discrete commands to process equipment, solenoid valves and interposing relays. Its 32 nominal 24 VDC outputs translate the control application's on/off commands into field signals. Individual channels can operate as latched, pulsed or pulse-width-modulated outputs and support direct or reverse output logic. Configurable failure behavior and internal diagnostics provide output supervision, while optional redundancy supports the relevant system arrangement. This is the electronic output module used with its applicable IOTA and, where required, a supported relay extension.
Hardware specifications. The 8C-PDODA1 has a 24 VDC voltage rating and a 105 mA module current rating. The maximum load voltage is 30 VDC; load current is limited to 100 mA per channel and 3.2 A per module. The specified turn-on or turn-off time is 10 ms maximum, and OFF-state leakage is 5 μA maximum. The module electronics are conformally coated.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer | Honeywell |
| Complete part number | 8C-PDODA1 51454472-175 |
| Product family | Series 8 I/O |
Functional Configuration |
|
| I/O function | Bussed 24 VDC digital output |
| Output channels | 32 |
| Output modes | Latched, pulsed or pulse-width modulated, per channel |
| System-to-field isolation | 1000 VAC RMS or ±1500 VDC; external user-supplied field power required |
| Nonredundant IOTA | 8C-TDODA1, coated, 9 in |
| Redundant IOTA | 8C-TDODB1, coated, 12 in |
| Relay extension | 8C-SDOX01, separate relay extension board |
Performance & Power |
|
| Voltage rating | 24 VDC |
| Module current rating | 105 mA |
| Maximum load voltage | 30 VDC |
| Maximum load current | 100 mA per channel; 3.2 A per module |
| Typical ON-state voltage | 24 VDC at up to 0.1 A load current |
| Maximum OFF-state leakage | 5 μA |
| Maximum turn-on / turn-off time | 10 ms |
Environment |
|
| Protection of electronics | Conformal coating |
System compatibility. The 8C-PDODA1 is part of Honeywell’s Series 8 I/O and C300 controller platform. It supports optional redundancy, direct or reverse output operation, and latched, pulsed or pulse-width-modulated operation per channel. FAILOPT can hold the last output value or move to a configured safe value. For applications requiring isolated dry contacts, Honeywell documents the separate 8C-SDOX01 relay extension used with the DO IOM and IOTA; the base module does not itself provide those relay contacts.
Use the model-specific Series 8 IOTA and the installed system wiring documentation. The reference PDF provides the applicable connection limits, termination-assembly choices and configuration notes.
| Check | Requirement | Application |
|---|---|---|
| Output bank | 32 bussed 24 VDC outputs | Common return and supply |
| Load limit | 100 mA per channel | 3.2 A maximum per module |
| IOTA | 8C-TDODA1 / 8C-TDODB1 | Nonredundant / redundant |
The module plugs onto its IOTA, where the field terminals and power distribution are located. Confirm the installed termination assembly before moving wiring.
Use the specified 8C-TDODA1 nonredundant IOTA or 8C-TDODB1 redundant IOTA. Confirm the actual IOTA wiring arrangement before replacement.
All outputs share a return and selected power source. An IOTA wiring option selects the Series 8 system supply or external field supply; system-to-field isolation requires external user-supplied power.
Keep loads within 30 VDC, 100 mA per channel and 3.2 A per module. Honeywell’s detailed note specifies four series fuses for the 32 channels on the DO IOTA. Review each channel’s FAILOPT setting for the connected equipment.
Relay loads. Dry-contact applications use the separately specified 8C-SDOX01 relay extension with the DO IOM and IOTA. Do not apply the relay board’s higher contact ratings to the module’s 100 mA outputs.
Field isolation. The documented isolation option is conditional on external user-supplied power; a common internal supply does not provide the same system-to-field isolation arrangement.
The base module provides bussed 24 VDC digital outputs. Honeywell documents the separate 8C-SDOX01 relay extension board, connected to the DO IOM and IOTA, for isolated dry-contact outputs.
The specified limits are 30 VDC maximum load voltage, 100 mA maximum per channel and 3.2 A maximum per module. The module’s 105 mA current rating is a separate rating and must not be confused with the field-load limit.
Honeywell describes the module as a bussed output device: all outputs share a common return and the same selected power source. The system-to-field isolation option requires external user-supplied power; it is not a statement of individual channel isolation.
Use 8C-TDODA1 for nonredundant operation or 8C-TDODB1 for redundant operation. Honeywell lists their nominal sizes as 9 inches and 12 inches respectively.
The documented modes are latched, pulsed or pulse-width modulated, configurable per channel. Direct or reverse output support is also listed.
FAILOPT is configured per channel and can hold the last output value or move to a user-configured safe value. Check the actual application setting when replacing a module.
The model-specific detailed specification states that the DO IOTA uses four series fuses for its 32 output channels. Check the installed IOTA and its approved wiring before treating output protection as adequate for the connected load.
A 10 mA load at 5 V DC meets the 8C-SDOX01 minimum only for a contact without prior high-current or high-voltage service. After high-current or high-voltage use, the minimum load current is 100 mA.
Product identification and application notes, followed by selected Honeywell original pages covering Series 8 hardware, the matching IOTA and model-specific electrical limits.
PDF · 8 pages · 116.1 KB · Compiled by EWOLO CONTROL. Honeywell S803-150-530, May 2024, Version 1.0.
Preview Product Reference (PDF)Series 8 nonredundant digital output IOTA
Series 8 redundant digital output IOTA
Series 8 32-channel relay extension board
Series 8 16-channel differential HART analog input module
Series 8 16-channel single-ended HART analog input module
Series 8 16-channel single-ended analog input module
Series 8 16-channel RTD and thermocouple input module
Series 8 16-channel HART analog output module
Series 8 16-channel analog output module without HART
Series 8 32-channel 24 VDC digital input module
Series 8 32-channel sequence-of-events input module
Series 8 digital input and pulse accumulation module
Series 8 nonredundant analog output IOTA
Series 8 redundant analog output IOTA
Series 8 nonredundant digital input IOTA
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Yokogawa AAI543-H50 is a 16-channel isolated 4–20 mA output module for CENTUM FIO. It supports HART communication and standard-response switching in a dual-redundant configuration. Version check: Match the -H50 standard switchover response, hardware Style and terminal option; a redundant pair must use the same response class.
Yokogawa AAI841-H00 is a non-isolated FIO module with eight 4–20 mA inputs and eight 4–20 mA outputs. It supports up to eight loops, HART communication and dual-redundant configurations. Version check: Confirm the legacy -H00 code, hardware Style, node and terminal option; HART in an ER-bus remote node requires EB401 Rev. 2 or later.
Yokogawa AAP135-S50 is an eight-channel isolated pulse input module for CENTUM FIO. It accepts contact, voltage-pulse and current-pulse signals, with frequency limits determined by the selected signal and redundancy configuration. Version check: Match pulse source, frequency, transmitter supply and redundancy mode; dry-contact limits are lower than the 10 kHz electronic-pulse limit.
Yokogawa ADV151-P60 is a 32-channel 24 V DC digital input module for CENTUM FIO. The P version supports pushbutton input, and suffix 6 provides input-status display without explosion protection. Version check: Confirm -P60 pushbutton capability, status display, hardware Style and input polarity; do not substitute an output or SOE-capture version.
Yokogawa ADV551-P60 is a 32-channel current-sink transistor output module for CENTUM FIO. It supports status, pulse-width and time-proportioning output patterns with output-status display. Version check: Match -P60, sink-output load and configured point-mode pattern; check paired-channel and redundancy restrictions before replacement.
Yokogawa ALR121-S50 is a two-port RS-422/RS-485 serial communication module for CENTUM N-IO/FIO systems. It exchanges subsystem data with the FCS using supported functions such as Modbus RTU and FA-M3 communication. Version check: Confirm RS-422/RS-485, the common protocol selected for both ports, baud rate, data mapping and the installed redundancy arrangement.
Yokogawa EC401-50 is a one-port ESB bus coupler for CENTUM N-IO/FIO. It links the field control unit to supported ESB nodes at 128 Mbps and supports single or dual-redundant module arrangements. Version check: For a CP471 system, require EC401 Style S3 or later; also match the one-port ESB topology, node types and redundancy arrangement.
Yokogawa EC402-50 is a two-port ESB bus coupler for CENTUM N-IO/FIO. Its upper and lower ESB connections link supported field control units to I/O nodes at 128 Mbps. Version check: Match the two-port ESB topology and system release; the 12-nodes-per-port exception applies only to the specified A2FV50 star configuration.