ISO 9001:2015 certified industrial automation spare parts supplier

Bently Nevada 125800-01 Keyphasor I/O Module

Bently Nevada 125800-01 is the non-isolated, internal-termination Keyphasor I/O spare for the 3500/25 family. It connects the field signal side of a compatible Keyphasor monitoring assembly.

Version check: Confirm 125800-01, non-isolated inputs and internal terminations against the installed 3500/25 assembly before ordering.

Download
  • Bently Nevada 125800-01 Keyphasor I/O Module

    Bently Nevada 125800-01 is the non-isolated Keyphasor I/O module with internal terminations for the 3500/25 Enhanced Keyphasor assembly. It provides the rear signal interface used with proximity probes or magnetic pickups, while the associated Keyphasor module converts shaft-reference events into timing signals for the 3500 system. Those timing references support rotational-speed measurement and vibration analysis such as 1X amplitude and phase. The complete 125800-01 part number identifies the internal-termination I/O choice, separate from the front processing module and the isolated or external-termination variants.

    Hardware specifications. The manufacturer lists a non-isolated signal-input range of +0.8 to -21.0 V and a minimum input impedance of 21.8 kOhm for the Keyphasor assembly. The I/O envelope is 241.3 x 24.4 x 103.1 mm (H x W x D). The published operating temperature for non-barrier I/O applications is -30 to +65 degrees C. These are distinct from the half-height front module dimensions.

    Technical Specifications

    Parameter Specification

    Product Identity

    Part number 125800-01
    I/O dimensions (H x W x D) 241.3 x 24.4 x 103.1 mm
    Rack space One full-height rear slot

    Functional Configuration

    Family 3500/25 Enhanced Keyphasor
    Termination Internal
    Isolation version Non-isolated I/O
    Published non-isolated signal range +0.8 to -21.0 V

    Performance & Power

    Input impedance 21.8 kOhm minimum

    Environment

    Operating temperature -30 to +65 degrees C, non-barrier I/O application
    Storage temperature -40 to +85 degrees C
    Humidity 95%, non-condensing

    Compatibility & Selection Guide

    System compatibility. The associated 3500/25 module supplies timing-reference signals to 3500 monitors for shaft speed and vector measurements. Its sensor and signal-processing configuration must suit the installed application. The manufacturer distinguishes ordinary, isolated and internal-barrier I/O versions; replacing 125800-01 with another type requires checking that distinction, rather than matching only the Keyphasor family name.

    Wiring & Installation Reference

    Use the current manufacturer reference to check the exact module, its documented system position and applicable termination arrangement.

    Internal Keyphasor connections

    1. Confirm isolation requirements

      Distinguish the non-isolated 125800-01 from isolated 125800-02 and internal-barrier 135473-01.

    2. Check the sensor signal

      Match the sensor, non-isolated input range and intended Keyphasor configuration to the manufacturer requirements.

    Use the internal-termination arrangement identified for 125800-01. Do not attach an external termination block to this I/O type.

    View Keyphasor module layout (PDF)

    Rear I/O and main-module arrangement

    1. Identify the replacement side

      Check whether the existing fault concerns the rear I/O or the front main module.

    2. Check the rack arrangement

      Use the manufacturer mounting arrangement for the selected Keyphasor main-module configuration.

    The I/O uses a full-height rear slot; the Enhanced Keyphasor main module is a separate half-height front assembly.

    View mounting reference (PDF)

    Selection and handling notes

    • 125800-01 is the non-isolated internal-termination I/O spare. The manufacturer lists the isolated internal-termination I/O under a different complete part number; confirm the installed input configuration.

    • Match the internal-termination arrangement before replacement. An external-termination I/O module is a different documented variant.

    Frequently Asked Questions

    How is 125800-01 different from 125800-02?

    125800-01 is the ordinary internal-termination Keyphasor I/O. The manufacturer identifies 125800-02 as the isolated internal-termination version, designed for magnetic-pickup applications. Isolation and signal range differ, so they should not be selected only by similar part numbers.

    Can 125800-01 be connected through a Keyphasor external termination block?

    No. The manufacturer states that external termination blocks cannot be used with internal-termination I/O modules. For an external-termination arrangement, select the applicable external I/O and order its required block and cable separately.

    Is 125800-01 itself the two-channel Enhanced Keyphasor main module?

    No. The spare-parts table lists 125800-01 as an I/O module and separately identifies 149369-01 as the Enhanced Keyphasor main module. Check whether the required replacement is the front processing module or the rear signal connection.

    What sensor-speed limitation matters when using 125800-01 with passive magnetic pickups?

    The Keyphasor datasheet states that passive magnetic pickups require shaft speed greater than 200 rpm (3.3 Hz). This is a system input condition, not a declaration that the I/O part independently processes speed. Check the intended sensor and configured Keyphasor application.

    Is 125800-01 the correct version when signal isolation is required?

    125800-01 is the non-isolated version. The manufacturer describes isolated Keyphasor I/O for signals connected in parallel to multiple devices and identifies separate isolated spare numbers. Confirm the isolation requirement, transducer supply and phase-measurement implications before changing versions.

    Can the 3500/25 paired with 125800-01 derive one reference pulse per turn from a multi-tooth wheel?

    The Enhanced Keyphasor supports generation of one event per turn from multiple input events per turn.

    What signal level is needed for automatic triggering of a Keyphasor channel using 125800-01?

    The 3500/25 auto threshold requires a signal of at least 2 V peak-to-peak and an input rate of at least 2 Hz.

    What output impedance applies when monitoring a buffered Keyphasor signal with 125800-01?

    The published maximum for the buffered output is 504 Ω. The front monitor provides coaxial buffered connections.

    Manufacturer Documentation

    125800-01 Product Reference

    Product photograph, identification and technical reference, with selected manufacturer pages covering the documented component and its system requirements.

    PDF · 7 pages · 117.7 KB · Compiled by EWOLO CONTROL. Manufacturer references: 141532 Rev. Y.

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Bently Nevada 125800-01

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message