ISO 9001:2015 certified industrial automation spare parts supplier

Honeywell CC-PAOH51 51410070-275 HART Analog Output Module

Honeywell CC-PAOH51 51410070-275 is a Series C high-level analog output module for Experion PKS. It supplies 16 current-output channels for actuators and recording or indicating devices, with HART configuration and status support.

Version check: Match the complete module code, CC-TAOX51/CC-TAOX61 termination assembly and installed system configuration. Other Series C output modules use different IOTAs and are not assumed to be interchangeable.

Download
  • Series C current outputs with HART configuration and status

    Honeywell CC-PAOH51 51410070-275 is a Series C HART analog output module for driving actuators and recording or indicating instruments from an Experion PKS control application. Its sixteen 4–20 mA channels carry the commanded process outputs, while HART communication supports field-device configuration and status information. Open-wire indication and internal self-diagnostics help identify channel or module problems. Each output can be configured to hold its last value or move to a selected safe value under the applicable failure condition, and the module supports the corresponding redundant Series C arrangement.

    Honeywell specifies a directly settable output of 0 mA or 2.9–21.1 mA, calibrated accuracy of ±0.35% of full scale at 25°C including linearity, and an 800-ohm maximum resistive load with a 22–28 VDC supply. Output response settles within 1% of its final value in 80 ms. These limits apply under the stated manufacturer conditions.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer / complete model Honeywell / CC-PAOH51 51410070-275
    Product family Experion PKS Series C high-level analog output

    Functional Configuration

    Output channels / nominal signal 16 / 4–20 mA
    HART function Configuration and status; model-specific function matrix applies
    Maximum resistive load 800 ohms with 22–28 VDC supply
    Redundant switchover output gap 10 ms maximum; redundancy only
    Non-redundant / redundant IOTA CC-TAOX51, 6-inch / CC-TAOX61, 12-inch
    Channel failure behavior FAILOPT: hold last value or shed to safe value; IOM electronics failure drives output to zero

    Performance & Power

    Directly settable output current 0 mA; 2.9–21.1 mA
    Calibrated output accuracy ±0.35% of full scale at 25°C, including linearity
    Output current linearity ±0.05% of full scale, nominal
    Output readback accuracy ±4% of full scale
    Output temperature drift 0.005% of full scale per °C
    Maximum output compliant voltage 16 V with 22–28 VDC supply
    Maximum open-circuit voltage 22 V
    Output response Settles within 1% of final value in 80 ms

    Environment

    Enclosure requirement Series C open equipment for subpanel mounting inside a suitable enclosure.

    Compatibility & Selection Guide

    The Series C specification covers Experion I/O and the C300 controller. CC-PAOH51 uses the 6-inch CC-TAOX51 non-redundant IOTA or the 12-inch CC-TAOX61 redundant IOTA; a redundant arrangement also requires the corresponding module pair and configuration. Its HART function is configuration/status, so do not infer HART control-variable or fast-control support from other Series C models.

    Wiring & Installation Reference

    Verify the exact CC-TAOX51 or CC-TAOX61 assembly and field-loop design before wiring. The compact reference contains OEM mounting, power-test warnings and HART output-protection information; it does not include the complete terminal drawings.

    Output loop and protection checks

    Item Required check Applicable limit
    Load budget Include the field device and wiring resistance Maximum 800 ohms with 22–28 VDC supply
    Signal polarity Match the IOTA OUT+ and OUT− terminals Use the terminal drawing for the actual non-redundant or redundant IOTA
    External reverse polarity Follow the OEM protection condition A reverse-polarity external source requires current limited to 500 mA to protect IOTA surge diodes

    Protection scope: The OEM permits a short across a field-wiring pair without damaging the module or IOTA and without affecting other channels. This is a fault-protection statement, not permission to omit isolation or hazardous-area precautions.

    Open OEM HART output-protection reference (PDF page 5)

    Mounting sequence

    1. Isolate and prepare

      Turn off power at the installation location as required by the OEM procedure. Apply ESD precautions and confirm that the area and work permit the installation.

    2. Check the termination assembly

      Mount the correct IOTA on its backplane before fitting the module. Confirm primary and redundant positions against the system design; do not choose an IOTA by physical fit alone.

    3. Seat and secure

      Mate the circuit board and IOTA connector, then secure the side screws and long front plastic screw. Use a No. 2 Phillips hand screwdriver; a No. 1 tip or power driver can damage the plastic screw.

    Open OEM mounting and power warnings (PDF pages 3–4)

    Installation precautions

    • Power and hazardous areas: Do not connect or disconnect cables, or install or remove components, while the control system is powered unless the location is known to be non-hazardous and the applicable OEM procedure permits the operation.

    • Busbar measurements: Never probe the 24 V screw hole of an unattached IOTA. The probe can contact the back channel assembly and short the carrier supply; use the designated OEM test points.

    • Commissioning and replacement: Verify channel mapping, load resistance, HART requirements and configured FAILOPT behavior before returning the loop to service. Use the complete OEM guide for terminal drawings and redundant wiring.

    Frequently Asked Questions

    What field signals does CC-PAOH51 51410070-275 provide?

    It provides 16 high-level current-output channels with a nominal 4–20 mA signal. The directly settable values are 0 mA or 2.9–21.1 mA; do not substitute a voltage-output specification from another module.

    Does CC-PAOH51 51410070-275 support HART control variables?

    The manufacturer function matrix identifies HART configuration and status for CC-PAOH51. It does not identify this model as supporting HART on control or HART fast control. Confirm the required HART function before selecting a replacement.

    Which IOTAs match CC-PAOH51 51410070-275?

    Honeywell lists CC-TAOX51 for a 6-inch non-redundant arrangement and CC-TAOX61 for a 12-inch redundant arrangement. A redundant installation also requires the appropriate module pair and system configuration; a redundant IOTA by itself does not establish a complete redundant system.

    How much load can CC-PAOH51 51410070-275 drive?

    The specified maximum resistive load is 800 ohms with a supply between 22 and 28 VDC. Include field-device and wiring resistance in the loop budget. The maximum output compliant voltage is 16 V under the same supply condition.

    What happens to CC-PAOH51 51410070-275 outputs on a failure?

    FAILOPT is configured per channel to hold the last value or shed to a safe value. The specification separately states that an IOM electronics failure drives the output to zero. Review the process consequences and configured strategy before commissioning or replacing the module.

    Why is CC-PAOH51 51410070-275 readback accuracy different from output accuracy?

    Honeywell specifies output readback accuracy as ±4% of full scale, while calibrated output accuracy is ±0.35% of full scale at 25°C including linearity. These describe different measurements; do not use the readback figure as the calibrated output-accuracy claim.

    Does the CC-PAOH51 51410070-275 PDF contain every terminal drawing?

    No. It contains one branded summary and three unchanged OEM pages covering mounting, the continuing power warning and HART output protection. Use the complete Series C I/O User Guide section 5.6 for CC-TAOX51/CC-TAOX61 terminal drawings and the applicable redundant arrangement.

    How much output ripple can CC-PAOH51 51410070-275 produce across a 250 Ω load?

    At the power-line frequency, the ripple is less than 100 mV peak to peak across 250 Ω.

    Manufacturer Documentation

    CC-PAOH51 51410070-275 Product Reference

    A concise product summary with selected Honeywell mounting, power-warning and HART analog output-protection pages. Terminal drawings remain in the complete OEM guide.

    PDF · 5 pages · 54.0 KB · Compiled by EWOLO CONTROL. Honeywell EPDOC-X126-en-A, November 2019; selected pages 73, 74 and 128.

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Honeywell CC-PAOH51 51410070-275

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.