ABB AX522 1SAP250000R0001 Analog Input/Output Module

ABB AX522 1SAP250000R0001 combines eight analog inputs and eight analog outputs for AC500 systems using S500 I/O. It supports voltage, current and resistance-temperature inputs; current output is available on channels 0 to 3.

Version check: Confirm the complete ordering code, configured signals and terminal unit for your application. AX522-XC is a separate variant.

Download
  • ABB AX522 1SAP250000R0001 S500 Analog I/O Module

    S500 analog signal interface. ABB AX522 1SAP250000R0001 is a standard S500 analog input/output module that combines process measurement and analog control signals in an AC500 I/O station. It provides eight inputs for individually configured voltage, current or supported resistance-temperature signals, plus eight voltage outputs; the first four output channels can alternatively provide current signals. This mixed I/O arrangement allows a single module to collect sensor values and send commands to analog field devices. Channel indications and configurable signal ranges help the module fit the measurement and output functions required by the control application.

    Eight inputs and eight outputs. The inputs support voltage, current and Pt100/Pt1000/Ni1000 modes. All eight outputs support voltage; current output is available only on channels 0 to 3. Channel resolution depends on the configured signal range. Channels are isolated from the I/O bus, but not from each other or from the UP/ZP process supply.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer / ordering code ABB / AX522 1SAP250000R0001; standard variant
    Product family S500 I/O for AC500 CPU or communication interface
    Terminal unit TU515 or TU516; terminal unit selection must match the installation
    Module weight 300 g

    Functional Configuration

    Analog inputs 8 channels in one group; voltage, current and resistance-temperature modes
    Input signal ranges 0–10 V, ±10 V, 0–20 mA, 4–20 mA; Pt100, Pt1000 and Ni1000 temperature modes
    Analog outputs 8 voltage outputs; current output available on channels 0–3 only
    Output signal ranges ±10 V, 0–20 mA or 4–20 mA, according to channel capability
    Electrical isolation From I/O bus: yes. Between channels: no. From UP/ZP process supply: no.

    Performance & Power

    Input resolution 12 bits for unipolar voltage/current ranges; 12 bits including sign for ±10 V. Temperature resolution depends on sensor mode.
    Output load Current mode: 0–500 Ω. Voltage mode: maximum ±10 mA.
    Process supply 24 V DC, −15% / +20%; observe the applicable supply and protection requirements

    Environment

    Operating temperature Horizontal mounting: 0 to +60 °C. Vertical mounting: 0 to +40 °C with 50% load derating.
    Protection IP20 when fully assembled; installation in a closed cabinet

    Compatibility & Selection Guide

    Master-controlled configuration. The I/O-bus master transfers the channel parameters at power-up; the AX522 does not store this configuration independently. ABB describes Control Builder Plus / Automation Builder parameterization for module firmware greater than V2.0.0. Check the existing controller project and firmware before replacement.

    Wiring & Installation Reference

    Reference: ABB AC500 V2 Hardware Manual, 3ADR010121 Rev.26. The linked Product Reference summarizes installation requirements and retains selected original safety and output-wiring pages. Use the complete ABB manual linked inside the PDF for input-sensor and other signal-specific arrangements.

    Supply and signal connections

    Connection Function Required check
    UP / ZP +24 V / 0 V process supply Use the documented supply protection and SELV/PELV separation
    Analog inputs Configured voltage, current or RTD signal Match sensor type and the exact ABB wiring arrangement
    Analog outputs Voltage on 0–7; current on 0–3 Check channel mode and load; leave unused outputs open
    AGND / ZP Analog reference / supply reference Keep the potential difference within 1 V

    The selected original output-wiring page identifies the current-capable channels and configuration behavior. Input-sensor wiring, passive-current precautions, RTD and differential arrangements require their signal-specific instructions in the complete ABB manual.

    View analog output wiring reference

    Installation and replacement

    1. Confirm the station

      Check the AX522 order code, TU515/TU516 terminal unit, I/O-bus master project and required channel signals before replacing a module.

    2. Isolate and mount

      Switch off supply and process voltage before wiring or replacement. Secure the terminal unit on the approved DIN rail or wall arrangement, and preserve natural ventilation and the documented cabinet clearance.

    3. Wire and restore configuration

      Follow ABB’s signal-specific drawings, shielding and equipotential-bonding instructions. At startup the I/O-bus master transfers parameter data; verify the channel modes and module diagnostics before use.

    View safety and grounding precautions

    Installation precautions

    • AX522 is not a safety module. Do not use it for safety functions or in a hazardous environment unless the applicable equipment and installation are expressly approved for that use.

    • Use SELV/PELV supplies with safe separation. Keep AGND-to-ZP potential difference within 1 V, use shielded analog cables and follow ABB’s equipotential-bonding instructions.

    • This reference does not establish eligibility for hot swapping. Power off before wiring or replacement; the manual’s conditional hot-swap provisions must not be treated as blanket permission.

    • Passive-current inputs have specific overcurrent protection behavior. Review the original precautions before connecting or restoring a loop.

    Frequently Asked Questions

    Which output channels on AX522 1SAP250000R0001 can drive a current signal?

    Only channels 0 to 3 support current output. All eight channels support voltage output. Check the configured range and the connected load before wiring; the stated current-output load is 0–500 Ω.

    Are the channels of AX522 1SAP250000R0001 individually isolated?

    No. ABB lists isolation from the I/O bus, but no isolation between analog channels or from UP/ZP. Review the common reference, shielding and equipotential bonding; AGND-to-ZP potential difference must remain within 1 V.

    Does AX522 1SAP250000R0001 retain its configuration when replaced?

    The I/O-bus master sends the parameters at power-up; the module does not store the configuration independently. Verify the controller project, channel modes and terminal unit before replacement rather than expecting the removed module to carry the settings.

    Which engineering software applies to AX522 1SAP250000R0001?

    The hardware manual describes Control Builder Plus / Automation Builder parameterization for firmware greater than V2.0.0. Confirm the installed firmware and the existing AC500 project; that statement does not establish support for every software release or controller.

    Can AX522 1SAP250000R0001 be removed while the station is powered?

    Do not assume this is permitted. ABB requires power to be disconnected before wiring or replacement unless all specified hot-swap conditions are satisfied. The terminal unit permits wiring to remain in place during replacement, but this alone does not establish hot-swap eligibility.

    Can AX522 1SAP250000R0001 use the same replacement selection as AX522-XC?

    Treat them as separate variants. The standard AX522 ordering code is 1SAP250000R0001; the XC version has a different ordering code and environmental specification. Match the complete code and application conditions rather than relying on the similar model name.

    What must be checked after process supply loss on AX522 1SAP250000R0001?

    Check the UP/ZP process supply and the station diagnostics. ABB states that after loss of UP/ZP supply the I/O station must be switched off and on for initialization. Follow the machine’s safe restart procedure and confirm the required channel configuration before operation.

    How quickly does an AX522 1SAP250000R0001 analog output settle after a full-range step?

    With a resistive load, the output typically settles within the specified tolerance in 5 ms.

    Manufacturer Documentation

    ABB AX522 1SAP250000R0001 Product Reference

    Verified product summary with selected ABB safety, grounding and analog-output wiring pages. This Product Reference is not the complete original manual.

    PDF · 4 pages · 122.2 KB · Compiled by EWOLO CONTROL. Selected pages from ABB AC500 V2 Hardware Manual, 3ADR010121 Rev.26 (2026-08-21).

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    ABB AX522 1SAP250000R0001

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.