ISO 9001:2015 certified industrial automation spare parts supplier

ABB 3BHE041626R0101 PDD405 A101 Control Hub

ABB 3BHE041626R0101 PDD405 A101 is a control hub for the ACS580MV drive control architecture. It links the inverter unit with the control compartment and carries inverter-control and cabinet-monitoring signals through the internal control system.

Version check: Match the complete 3BHE041626R0101 / PDD405 A101 identification, fitted daughterboards and drive-specific configuration; check that the replacement control-hub software matches the installed drive.

Download
  • ABB 3BHE041626R0101 PDD405 A101 Control Hub

    ABB 3BHE041626R0101 PDD405 A101 is a control hub used at the interface between an ACS580MV inverter unit and its control compartment. It carries the signals needed for inverter control and inverter-cabinet monitoring, while DDCS optical communication transfers data through the hub to the PEBB control boards inside the power modules. For maintenance teams sourcing a replacement, the complete ABB order code and A101 identification distinguish this unit from other drive-control assemblies. The control hub works within the drive control system alongside the BCU main control unit; it is not a complete drive or a standalone motor controller.

    Hardware specifications. The PD D405 control-hub assembly incorporates plug-in daughterboard positions, optical-fiber connections, an X1 power connector and X2 signal connections. The illustrated assembly also has a pressure connection. Match the fitted daughterboards and connector arrangement to the installed drive drawings; the number of fitted daughterboards and the supplied accessories must be confirmed for the offered unit.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer ABB
    Order code 3BHE041626R0101
    Type designation PD D405 A101 / PDD405 A101
    Product type Control hub
    Construction Control-hub board with plug-in daughterboard positions

    Functional Configuration

    Documented drive architecture ACS580MV
    System role Interface between inverter unit and control compartment
    Internal data path DDCS optical communication to PEBB control boards
    Software replacement requirement Check and match control-hub software to the installed drive

    Performance & Power

    Power / signal identification X1 power connector; X2 signal connections

    Environment

    Spare board storage temperature −5 to +55 °C in the original packaging, with the circuit board in an antistatic bag or box.

    Compatibility & Selection Guide

    System compatibility. The ACS580MV control architecture uses the BCU for general drive, motor-control and closed-loop functions, with the control hub providing the inverter-side interface. Replacement control-hub software must match the drive software configuration. Check the complete spare-part identification and the drive-specific documentation before substitution; a similar board appearance alone does not establish interchangeability.

    Wiring & Installation Reference

    Use the ACS580MV drawings and safety instructions applicable to the installed cabinet. The following is an identification and service overview, not a substitute for the complete shutdown and grounding procedure.

    Connections and identification

    Optical links. Identify and label each fiber connection before removal. Restore each link to its original position and match the fitted daughterboard arrangement.

    Power and signals. X1 identifies the power connection and X2 the signal connections. Check the cabinet-specific circuit diagrams before disconnecting or reconnecting the pressure tube and other wiring.

    View control-hub connections (PDF)

    Control-hub replacement

    1. Isolate the drive.

      A qualified electrician must stop, de-energize, lock out and ground the drive according to the complete ABB procedure, including auxiliary supplies and the required discharge and voltage checks.

    2. Identify and remove.

      Switch off the control-compartment miniature circuit breakers. Label and disconnect the relevant fibers, power, signals and pressure tube. Support the assembly before releasing its mounting screws.

    3. Restore and verify.

      Install the approved replacement in reverse order, restore the original connection positions and check the drive-specific configuration and software before the authorized restart procedure.

    View control-hub mounting reference (PDF)

    Power and handling precautions

    • Hazardous voltage. Never replace the control hub with the drive energized. Follow the complete ACS580MV isolation, discharge, voltage-verification and grounding procedure; a stopped drive is not necessarily electrically safe.

    • ESD protection. Use grounded ESD protection, handle circuit boards by their edges and place them on a grounded ESD-protected work surface.

    Frequently Asked Questions

    What does 3BHE041626R0101 PDD405 A101 do in an ACS580MV drive?

    It provides the interface between the inverter unit and the control compartment, carrying inverter-control and inverter-cabinet monitoring signals. DDCS links transfer data through the hub to the PEBB control boards.

    Is 3BHE041626R0101 PDD405 A101 the same component as the BCU?

    No. The BCU performs the main drive, motor-control and closed-loop functions. The control hub is the interface to the inverter unit and its power-module control boards.

    Which identification should be matched when ordering 3BHE041626R0101 PDD405 A101?

    Match the complete ABB order code 3BHE041626R0101 and the PD D405 A101 designation, then confirm the drive-specific spare-part identification and fitted daughterboard arrangement. A matching family name alone is insufficient.

    Does 3BHE041626R0101 PDD405 A101 communicate with the power modules through optical fiber?

    Yes. The ACS580MV uses DDCS optical communication through the control hub to the PEBB control boards inside the power modules. Keep each fiber in its assigned position during replacement.

    What are X1 and X2 on 3BHE041626R0101 PDD405 A101?

    X1 is the power connector and X2 identifies signal connections on the illustrated PD D405 control-hub assembly. Use the installed cabinet drawings for the actual wiring assignment and supply requirements.

    Can 3BHE041626R0101 PDD405 A101 be replaced while the drive remains energized?

    No. A qualified electrician must complete the specified shutdown, isolation, discharge, voltage-verification and grounding procedure before replacement. Switch off the control-compartment miniature circuit breakers before disconnecting the hub.

    Must the software be checked when replacing 3BHE041626R0101 PDD405 A101?

    Yes. Check the replacement control-hub software and update it as required to match the installed drive software configuration before returning the drive to service.

    What should be confirmed about daughterboards supplied with 3BHE041626R0101 PDD405 A101?

    Confirm which daughterboards are fitted and included in the offered assembly, and compare their positions with the existing drive configuration. The daughterboards plug into slots on the control hub; the main board identification does not by itself specify the supplied accessory set.

    How should 3BHE041626R0101 PDD405 A101 be handled during maintenance?

    Use ESD protection and a grounded, ESD-protected work surface. Hold boards by their edges and avoid touching sensitive components. Handle a removed or faulty board with the same care as a replacement.

    Manufacturer Documentation

    3BHE041626R0101 PDD405 A101 Product Reference

    Product photograph, control-hub identification and replacement checks, followed by selected original ABB ACS580MV hardware-manual pages showing the control hub and daughterboard mounting.

    PDF · 4 pages · 112.7 KB · Compiled by EWOLO CONTROL. ABB ACS580MV 2UBB004520ES1 Rev. E, 27 June 2019; original pages 137–138 in Spanish.

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    ABB 3BHE041626R0101 PDD405 A101

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.