ISO 9001:2015 certified industrial automation spare parts supplier

Bently Nevada 133442-01 Tachometer I/O Module

Bently Nevada 133442-01 is the internal-termination I/O module listed for the 3500/50M tachometer assembly. It is the standard rear I/O option, distinct from the internal-barrier and external-termination variants.

Version check: Confirm 133442-01, internal terminations and the installed 3500/50M tachometer configuration before ordering.

Download
  • Bently Nevada 133442-01 Tachometer I/O Module

    Bently Nevada 133442-01 is the standard internal-termination I/O module for a compatible 3500/50M tachometer monitoring assembly. It provides the rear interface for proximity-probe or magnetic-pickup signals used by the front monitor to determine shaft speed, acceleration or direction. Depending on configuration, the complete assembly can support speed alarms, zero-speed notification, reverse-rotation indication and conditioned Keyphasor signals. The 133442-01 is the field-interface component rather than the processing monitor, and its standard internal-termination design distinguishes it from the external-termination and internal-barrier I/O options.

    Hardware specifications. The manufacturer specifies 20 kOhm input impedance for standard tachometer I/O and an input signal range of +10.0 to -24.0 V for the tachometer assembly. The non-barrier I/O envelope is 241.3 x 24.4 x 99.1 mm (H x W x D). Buffered outputs are available at the I/O through Euro-style connectors.

    Technical Specifications

    Parameter Specification

    Product Identity

    Part number 133442-01
    Component Tachometer I/O with internal terminations
    I/O dimensions (H x W x D) 241.3 x 24.4 x 99.1 mm
    Rack space One full-height rear slot

    Functional Configuration

    Documented family 3500/50M
    I/O version Standard non-barrier
    Buffered I/O outputs Euro-style connectors
    Host software 3500 Rack Configuration Software; check current monitor/TDI requirements
    Application exclusion Not a speed-control or overspeed-protection system

    Performance & Power

    Standard input impedance 20 kOhm
    Published tachometer input range +10.0 to -24.0 V

    Environment

    Hazardous-location ambient limit 3500/50M non-barrier configuration: T4, −20 to +65 °C under the applicable marking and drawing 149243 or 149244

    Compatibility & Selection Guide

    System compatibility. The associated 3500/50M monitor is configured with 3500 Rack Configuration Software for supported speed-related measurements. Its functions and restrictions depend on the transducer and configuration; magnetic pickups must not be used for reverse-rotation or zero-speed options. The current 3500/50M is not compatible with any version of 3500/20, so retaining the correct host environment matters when selecting 133442-01.

    Wiring & Installation Reference

    Use the current manufacturer reference to check the exact module, its documented system position and applicable termination arrangement.

    Sensor and function matching

    1. Check the transducer

      Confirm the transducer type and the applicable signal range.

    2. Review the configured function

      Preserve the manufacturer restrictions for zero speed, reverse rotation and recorder use.

    Use the standard internal-termination I/O arrangement and verify the configured tachometer function. Magnetic pickups are not allowed for the reverse-rotation or zero-speed options.

    View tachometer I/O layout (PDF)

    Rear I/O and host compatibility

    1. Match the I/O spare

      Confirm 133442-01 and distinguish the external and internal-barrier variants.

    2. Check the host environment

      For a 3500/50M installation, verify TDI firmware and configuration/software requirements from the ordering table.

    The standard rear I/O occupies one full-height rear slot. External termination blocks are not used with this version.

    View mounting reference (PDF)

    Selection and handling notes

    • Do not use the tachometer assembly for speed control or overspeed protection. Its analog proportional output is for logging, chart recording or display, and speed alerts are for annunciation only.

    Frequently Asked Questions

    Can 133442-01 be used as an overspeed protection module?

    No. The manufacturer warns that the 3500/50M tachometer must not be used independently or as part of a speed-control or overspeed-protection system. The I/O spare does not change that limitation.

    Can magnetic pickups be used for reverse-rotation or zero-speed functions with 133442-01?

    The manufacturer expressly excludes magnetic pickups for those two options because a clean detection edge is not provided at low speed. Confirm the transducer and selected channel function before using the standard tachometer I/O.

    Does 133442-01 connect to an external termination block?

    No. External termination blocks cannot be used with internal-termination I/O. The manufacturer separately lists 133434-01 as the external-termination I/O and requires external blocks and cables to be ordered separately for that arrangement.

    What distinguishes 133442-01 from 136703-01?

    133442-01 is standard internal-termination I/O. 136703-01 is the discrete internal-barrier I/O, with different input impedance and a deeper physical envelope. Internal-barrier systems also have earthing, transducer and wiring-separation requirements.

    Can 133442-01 prove that a replacement 3500/50M will work with an existing 3500/20?

    No. The current 3500/50M ordering requirements state that it is not compatible with any 3500/20 version. Review the front monitor, TDI firmware and software requirements, rather than treating the shared rear I/O spare number as proof of complete system compatibility.

    What input frequency limit applies to a 3500/50M measuring shaft speed through 133442-01?

    The host tachometer supports up to 20 kHz of input pulses and a maximum full-scale speed of 99,999 rpm. The pulse rate depends on the number of events per revolution.

    Can a 600 mV peak-to-peak signal trigger a 3500/50M using 133442-01?

    600 mV is above the 500 mV peak-to-peak minimum for manual threshold but below the 1 V minimum for auto threshold. The manual threshold still has to suit the signal level.

    What load can the recorder circuit of a 3500/50M with 133442-01 drive?

    Each recorder output is 4–20 mA into 0–600 Ω. The recorder value is proportional to the configured full-scale speed or acceleration range.

    Manufacturer Documentation

    133442-01 Product Reference

    Product photograph, identification and technical reference, with selected manufacturer pages covering the documented component and its system requirements.

    PDF · 8 pages · 126.0 KB · Compiled by EWOLO CONTROL. Manufacturer references: 141538 Rev. V.

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Bently Nevada 133442-01

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.