Allen-Bradley 1756-OF8I is a ControlLogix eight-channel isolated analog output module. Each channel can provide a voltage or current output for driving analog field devices with channel-to-channel isolation.
Version check: Confirm 1756-OF8I, channel output type, load resistance and RTB wiring. Review engineering-unit scaling and clamp limits before replacement.
Lifecycle status: Active
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Allen-Bradley 1756-OF8I is an eight-channel isolated analog output module for sending continuously variable control signals from a ControlLogix application to field devices. Each channel can be configured for voltage or current, and individual isolation allows the output circuits to remain electrically separate. Configurable output clamping restricts the commanded signal range, while ramping functions control how quickly an output changes under the selected operating conditions. Alarm and data-echo functions provide additional output information to the controller. These capabilities distinguish 1756-OF8I from non-isolated analog output options and help match the module to the signal type and response required by the connected equipment.
Hardware specifications. The 1756-OF8I provides eight channels with 16-bit resolution and selectable ±10V, 0–10V, 0–5V or 0–20mA ranges. Current-mode loads can be 0–1000Ω; voltage-mode loads must exceed 1000Ω. The module occupies one chassis slot and uses a 1756-TBCH or 1756-TBS6H removable terminal block.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer | Allen-Bradley |
| Catalog number | 1756-OF8I |
Functional Configuration |
|
| Output channels | 8, individually isolated; voltage/current combination |
| Voltage output ranges | ±10V, 0–10V or 0–5V |
| Current output range | 0–20mA |
| Data format | IEEE 32-bit floating point |
| Isolation | 250V continuous, output-to-backplane and output-to-output |
| Removable terminal block | 1756-TBCH or 1756-TBS6H |
Performance & Power |
|
| Resolution | 16 bits |
| Current-mode load | 0–1000Ω |
| Voltage-mode load | Greater than 1000Ω |
| Backplane current at 5.1V | 200mA |
| Backplane current at 24V | 220mA for voltage mode or 250Ω current loads; up to 385mA with 1000Ω current loads |
| Settling time | Less than 2ms to 95% of the final value with a resistive load |
| Minimum module scan time | 1ms |
Environment |
|
| Operating temperature | 0–60°C |
System and software compatibility. Configure the 1756-OF8I in the Logix Designer I/O project with the correct module revision, output type, range and engineering-unit scaling. Channel functions include ramping, hold for initialization and output clamps. When scaling changes, review the clamp settings separately because their engineering-unit values do not update automatically.
Choose voltage or current output on each channel and use its designated output connection and return.
| Connection | Use | Check |
|---|---|---|
| Voltage output | OUT-x/V and RTN-x | Use a load greater than 1000Ω. |
| Current output | OUT-x/I and RTN-x | Keep the loop load within 0–1000Ω. |
| Channel returns | Individual RTN-x connections | Preserve the channel-isolated wiring shown in the terminal diagram. |
Record each channel voltage/current mode, signal span, load resistance and required safe output state.
Use a keyed 1756-TBCH or 1756-TBS6H and follow the isolated-channel terminal diagram. Route and ground shields as specified.
Seat and lock the RTB. Check scaling, ramping, hold and clamp settings before returning the controlled process to service.
Remove power or establish a nonhazardous area before insertion, removal or disconnection; observe electrostatic-discharge precautions.
Ensure outputs cannot cause unintended equipment operation during wiring and commissioning. Verify the power budget for the actual output loads.
Yes. Configure the output type and range independently for each of its eight isolated channels. Use the corresponding voltage or current terminals for each channel.
Yes. It provides 250V continuous isolation between outputs and between the outputs and backplane.
Yes. Select current output and configure the required engineering-unit scaling within the 0–20mA range. Keep the connected load within the 0–1000Ω current-output limit.
Current-mode loads can be 0–1000Ω. Voltage-mode loads must be greater than 1000Ω; account for the total connected circuit resistance.
The high and low clamps use engineering units and do not automatically change when scaling is edited. Review and update the clamp limits to match the new scaling before assuming a hardware fault.
No. The 24V backplane demand depends on output mode and load: it is 220mA for voltage operation or 250Ω current loads and rises to 385mA for 1000Ω current loads. Include the actual load condition in the chassis power budget.
Match the module revision, voltage/current selection, RTB connections, load resistance, scaling and output clamp settings. Confirm the safe output behavior before restoring the control loop.
The ProgToFaultEn setting selects the behavior. An output can stay in its configured Program-mode state or switch to its configured Fault-mode behavior.
Product photograph, application notes and selected Rockwell Automation pages covering the current module.
PDF · 3 pages · 86.7 KB · Compiled by EWOLO CONTROL. 1756-TD002U-EN-E U
Preview Product Reference (PDF)ControlLogix 8-point diagnostic 120V AC input module
ControlLogix 16-point 120V AC input module
ControlLogix 16-point isolated 120V AC input module
ControlLogix 32-point 120V AC input module
ControlLogix 16-point isolated 240V AC input module
ControlLogix 16-point 24V AC input module
ControlLogix 16-point 12/24V DC sinking input module
ControlLogix 16-point isolated DC input module
ControlLogix 16-point high-speed isolated DC input module
ControlLogix 32-point DC sinking input module
ControlLogix 8-point single-ended analog input module
ControlLogix 8-channel isolated analog input module
ControlLogix configurable voltage/current analog input module
ControlLogix 4-channel voltage/current analog output module
ControlLogix 8-channel voltage/current analog output module
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Bently Nevada 140471-01 is the internal-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, internal terminations and 3500/42M configuration before replacing 140471-01.
Bently Nevada 140482-01 is the external-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, external terminations and 3500/42M configuration before replacing 140482-01.
Bently Nevada 149992-01 is the standard 16-channel relay output module used in the 3500/33 machinery-protection relay assembly. It provides the rear-rack switching interface for relay actions configured from the 3500 system's monitoring information. Version check: Confirm standard relay contacts, the minimum load, 149986-01 control module and required energized/de-energized logic before replacing 149992-01.
ProSoft Technology MVI56-DFCM connects a ControlLogix controller to DF1 serial devices through two independently configurable communication ports. Version check: Match the MVI56-DFCM application, DF1 device addressing and port modes; the reduced-data-block MVI56-DFCMR uses a different backplane transfer arrangement.
ProSoft Technology MVI56-DFCMR is a DF1 interface module for ControlLogix applications that use reduced backplane data transfers, including remote racks connected over ControlNet or Ethernet. Version check: Retain the MVI56-DFCMR reduced-block controller data structures and transfer logic; match each port’s DF1 mode, device address and file mapping.
ProSoft Technology MVI56-MCM adds two independent Modbus serial interfaces to a ControlLogix system. Version check: Preserve the MVI56-MCM controller project, register map and serial settings; migration to an enhanced MVI56E variant requires its applicable migration procedure.
ProSoft Technology MVI69-MNETC connects a 1769-based controller application to multiple Modbus TCP/IP server devices. Version check: Match MVI69-MNETC client-only operation, the 1769 controller program and power-supply distance; retain the installed firmware’s supported Ethernet options.
ProSoft Technology PLX31-EIP-MBS4 bridges EtherNet/IP controller data and four independent Modbus serial networks. Version check: Match the four-port PLX31-EIP-MBS4, serial interface modes, I/O connection sizes and installed firmware; retain the matching ProSoft Configuration Builder configuration.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :