Allen-Bradley 1756-IF16 is a ControlLogix voltage/current analog input module. It supports 16 single-ended, eight differential or four high-speed differential inputs for bringing analog process signals into the control system.
Version check: Confirm the module series, single-ended/differential mode, signal range and RTB wiring. The photographed unit is 1756-IF16 Series A.
Lifecycle status: Active
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Allen-Bradley 1756-IF16 is a configurable analog input module for converting field voltage and current measurements into data used by a ControlLogix application. It supports single-ended, differential and high-speed differential configurations, allowing the channel arrangement to match the signal source and required measurement update behavior. The module provides input scaling in engineering units, real-time sampling and data alarms, helping the controller use the measurements for monitoring and control. These functions make 1756-IF16 suitable for a range of analog signal-acquisition tasks, but the selected input configuration determines the available channel count and must be checked against the existing application.
Hardware specifications. The 1756-IF16 supports 16 single-ended inputs, eight differential inputs or four high-speed differential inputs. Selectable ranges are ±10V, 0–10V, 0–5V and 0–20mA, with 16-bit conversion for unipolar ranges. The module uses one chassis slot and a 1756-TBCH or 1756-TBS6H RTB. Channels are not individually isolated.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer | Allen-Bradley |
| Catalog number | 1756-IF16 |
Functional Configuration |
|
| Input configurations | 16 single-ended; 8 differential; 4 high-speed differential |
| Voltage ranges | ±10V, 0–10V or 0–5V |
| Current range | 0–20mA |
| Data format | Integer or IEEE 32-bit floating point |
| Channel isolation | No individual channel isolation; 250V continuous input-group-to-backplane isolation |
| Removable terminal block | 1756-TBCH or 1756-TBS6H |
Performance & Power |
|
| Resolution | 16 bits unipolar; 15 bits plus sign for bipolar voltage |
| Current-input impedance | 249Ω |
| Voltage-input impedance | At least 10MΩ |
| Single-ended scan time | 16–488ms, depending on notch filter |
| Differential scan time | 8–244ms, depending on notch filter |
| High-speed differential scan time | 5–122ms, depending on notch filter |
| Calibrated accuracy at 25°C | Better than 0.05% of range for voltage; better than 0.15% of range for current |
Environment |
|
| Operating temperature | 0–60°C |
System compatibility. The 1756-IF16 belongs to the ControlLogix analog I/O family and supports engineering-unit scaling, software-configurable alarms and integer or floating-point data. Match the input mode, channel assignments, notch filter and data format to the existing controller project; changing to high-speed differential operation reduces the available input count.
Select single-ended or differential operation first, then follow the voltage or current wiring diagram for that configuration.
| Connection | Use | Check |
|---|---|---|
| Single-ended voltage | IN-x referenced to RTN | The iRTN terminals are not used for voltage measurements. |
| Single-ended current | IN-x and corresponding iRTN | Connect the required iRTN-to-RTN jumpers as shown in the current-input diagram. |
| Differential inputs | Positive/negative input pairs | High-speed mode uses logical channels 0, 2, 4 and 6; do not copy single-ended terminal assignments. |
Confirm voltage/current signal type, single-ended or differential mode, field supply isolation and the expected signal span.
Use the correct 1756-TBCH or 1756-TBS6H, match mechanical keying and route shielded analog cables according to the installation instructions.
Seat and lock the RTB, verify shields and returns, and confirm channel mode, scaling, data format and notch filter in the controller project.
Use an appropriately isolated field supply and follow the manufacturer power and hazardous-location precautions before inserting, removing or disconnecting the module.
Protect the electronics from electrostatic discharge and do not treat the analog input channels as individually isolated.
It supports 16 single-ended inputs, eight differential inputs or four high-speed differential inputs. The channel count depends on the configured input mode.
Yes. Use the 0–20mA current range and configure scaling for the required 4–20mA measurement span. Match the current wiring and input configuration to the application.
No. The channels share the analog input circuitry; the 250V continuous isolation rating applies between the input group and backplane. Choose a channel-isolated module when the application requires isolation between individual inputs.
High-speed differential mode uses logical channels 0, 2, 4 and 6. Use the corresponding positive/negative input pairs in the differential wiring diagram.
Sampling time depends on both the input mode and notch-filter setting. The ranges are 16–488ms for single-ended, 8–244ms for differential and 5–122ms for high-speed differential operation.
Use a 1756-TBCH or 1756-TBS6H removable terminal block. Verify the signal type, channel pairing and module-specific terminal diagram before transferring an existing RTB.
No. Current inputs use the internal 249Ω shunt through the designated iRTN connections, while voltage input wiring does not use those current-return connections. Follow the diagram for the chosen single-ended or differential mode.
Input scans follow real-time sampling (RTS). The requested packet interval (RPI) also schedules data transfers. With RPI shorter than RTS, a transfer can repeat the last sampled values.
Product photograph, application notes and selected Rockwell Automation pages covering the current module.
PDF · 4 pages · 102.5 KB · Compiled by EWOLO CONTROL. 1756-TD002U-EN-E U; 1756-TD002M-EN-E M
Preview Product Reference (PDF)ControlLogix 8-point diagnostic 120V AC input module
ControlLogix 16-point 120V AC input module
ControlLogix 16-point isolated 120V AC input module
ControlLogix 32-point 120V AC input module
ControlLogix 16-point isolated 240V AC input module
ControlLogix 16-point 24V AC input module
ControlLogix 16-point 12/24V DC sinking input module
ControlLogix 16-point isolated DC input module
ControlLogix 16-point high-speed isolated DC input module
ControlLogix 32-point DC sinking input module
ControlLogix 8-point single-ended analog input module
ControlLogix 8-channel isolated analog input module
ControlLogix 4-channel voltage/current analog output module
ControlLogix 8-channel voltage/current analog output module
ControlLogix 8-channel isolated analog output module
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Bently Nevada 140471-01 is the internal-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, internal terminations and 3500/42M configuration before replacing 140471-01.
Bently Nevada 140482-01 is the external-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, external terminations and 3500/42M configuration before replacing 140482-01.
Bently Nevada 149992-01 is the standard 16-channel relay output module used in the 3500/33 machinery-protection relay assembly. It provides the rear-rack switching interface for relay actions configured from the 3500 system's monitoring information. Version check: Confirm standard relay contacts, the minimum load, 149986-01 control module and required energized/de-energized logic before replacing 149992-01.
ProSoft Technology MVI56-DFCM connects a ControlLogix controller to DF1 serial devices through two independently configurable communication ports. Version check: Match the MVI56-DFCM application, DF1 device addressing and port modes; the reduced-data-block MVI56-DFCMR uses a different backplane transfer arrangement.
ProSoft Technology MVI56-DFCMR is a DF1 interface module for ControlLogix applications that use reduced backplane data transfers, including remote racks connected over ControlNet or Ethernet. Version check: Retain the MVI56-DFCMR reduced-block controller data structures and transfer logic; match each port’s DF1 mode, device address and file mapping.
ProSoft Technology MVI56-MCM adds two independent Modbus serial interfaces to a ControlLogix system. Version check: Preserve the MVI56-MCM controller project, register map and serial settings; migration to an enhanced MVI56E variant requires its applicable migration procedure.
ProSoft Technology MVI69-MNETC connects a 1769-based controller application to multiple Modbus TCP/IP server devices. Version check: Match MVI69-MNETC client-only operation, the 1769 controller program and power-supply distance; retain the installed firmware’s supported Ethernet options.
ProSoft Technology PLX31-EIP-MBS4 bridges EtherNet/IP controller data and four independent Modbus serial networks. Version check: Match the four-port PLX31-EIP-MBS4, serial interface modes, I/O connection sizes and installed firmware; retain the matching ProSoft Configuration Builder configuration.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :