1756-IA8D
ControlLogix 8-point diagnostic 120V AC input module
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier



Allen-Bradley 1756-IA16I is a ControlLogix 16-point, individually isolated 120V AC input module. It monitors separate AC field signals and transfers their states to the controller.
Version check: Confirm 1756-IA16I, individual-input isolation and the 36-position RTB. It uses different terminal grouping from 1756-IA16.
Lifecycle status: Active
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Allen-Bradley 1756-IA16I is a 16-channel, individually isolated AC digital input module for bringing nominal 120 V AC field states into a ControlLogix controller. Each input has its own isolation from the other inputs and the backplane, supporting applications where the field circuits must remain electrically separate. The module converts the incoming on/off conditions into controller input data and provides selectable input filtering, configurable change-of-state reporting and input time stamps. These features help the application qualify and identify field-state changes. The individual isolation is a defining feature of 1756-IA16I and must not be assumed for other sixteen-channel AC input models.
Hardware specifications. The 1756-IA16I provides 16 inputs with a nominal 120V AC, 50/60Hz rating. Its operating input range is 79–132V AC at 47–63Hz. Input filtering is selectable, and the module supports change-of-state reporting and input timestamps. It occupies one chassis slot and uses a 1756-TBCH or 1756-TBS6H 36-position removable terminal block.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer | Allen-Bradley |
| Catalog number | 1756-IA16I |
| Chassis width | 1 slot |
Functional Configuration |
|
| Input points | 16, individually isolated |
| Nominal input voltage | 120V AC, 50/60Hz |
| Operating input range | 79–132V AC at 47–63Hz |
| Isolation | 125V continuous, input-to-backplane and input-to-input |
| Removable terminal block | 1756-TBCH or 1756-TBS6H; 36 positions |
Performance & Power |
|
| Off-to-on delay | 10ms maximum hardware delay plus selectable 1ms or 2ms filter |
| On-to-off delay | 8ms maximum hardware delay plus selectable 9ms or 18ms filter |
| Maximum off-state voltage | 20V AC |
| Maximum off-state current | 2.5mA |
| On-state current | 5mA minimum at 79V AC; 15mA maximum at 132V AC |
| Backplane current | 125mA at 5.1V DC; 3mA at 24V DC |
Environment |
|
| Operating temperature | 0–60°C |
System compatibility. The 1756-IA16I is part of the ControlLogix AC input family. For replacement, match the individual-input isolation, AC signal range, filter configuration and terminal arrangement to the existing application. A 1756-IA16 grouped-input module has a different terminal block and grouping, so the similar catalog number does not establish interchangeability.
Keep the individual AC input and return pairs separate when the application requires input-to-input isolation.
| Connection | Use | Check |
|---|---|---|
| IN-0 to IN-15 | AC input signal terminals | Match each field circuit to its designated input. |
| L2-0 to L2-15 | Corresponding AC returns | Preserve individual return wiring for isolated circuits. |
| 1756-JMPR | Optional L2 commoning | Use only for an intentional nonisolated wiring arrangement. |
Install the chassis and power supply, then establish a safe power and equipment state before inserting the module or wiring the RTB.
Use the 36-position 1756-TBCH or 1756-TBS6H. Set mechanical keying to match the module and follow the individual-input diagram.
Provide strain relief, assemble the housing, close the cover and fully seat and lock the RTB. Verify each field voltage and input filter in the project.
Remove field power before RTB handling; remove power or confirm a nonhazardous area before module insertion, removal or disconnection.
Follow electrostatic-discharge precautions and prevent unintended machine motion while I/O is disconnected.
Yes. Each of the 16 inputs is isolated from the other inputs, with a 125V continuous isolation rating to the backplane and between inputs.
It is a 120V AC input module with a 79–132V AC operating input range. Select an appropriate DC input module for a 24V DC field signal.
Do not assume a direct interchange. The 1756-IA16I has individually isolated inputs and a 36-position RTB; 1756-IA16 uses grouped inputs and a different terminal arrangement. Check the wiring and project configuration before selecting a replacement.
Use a 1756-TBCH or 1756-TBS6H 36-position removable terminal block. Confirm the correct mechanical keying and whether the terminal block is included.
Off-to-on response includes up to 10ms of hardware delay plus the selected 1ms or 2ms filter. On-to-off response includes up to 8ms of hardware delay plus the selected 9ms or 18ms filter.
The inputs can be wired with individual returns. A 1756-JMPR jumper can connect L2 returns for a nonisolated input arrangement; use that configuration only when shared returns are appropriate for the circuit.
Remove field-side power and keep controlled equipment in a safe state. In a hazardous location, remove power or confirm that the area is nonhazardous before disconnecting; an energized connection can produce an arc.
The 1756-TBE extended-depth terminal-block housing provides more room for routing field conductors. The wire-size limits of the selected terminal block still apply.
Product photograph, application notes and selected Rockwell Automation pages covering the current module.
PDF · 3 pages · 78.3 KB · Compiled by EWOLO CONTROL. 1756-TD002U-EN-E U
Preview Product Reference (PDF)ControlLogix 8-point diagnostic 120V AC input module
ControlLogix 16-point 120V AC input module
ControlLogix 32-point 120V AC input module
ControlLogix 16-point isolated 240V AC input module
ControlLogix 16-point 24V AC input module
ControlLogix 16-point 12/24V DC sinking input module
ControlLogix 16-point isolated DC input module
ControlLogix 16-point high-speed isolated DC input module
ControlLogix 32-point DC sinking input module
ControlLogix 8-point single-ended analog input module
ControlLogix 8-channel isolated analog input module
ControlLogix configurable voltage/current analog input module
ControlLogix 4-channel voltage/current analog output module
ControlLogix 8-channel voltage/current analog output module
ControlLogix 8-channel isolated analog output module
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Bently Nevada 140471-01 is the internal-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, internal terminations and 3500/42M configuration before replacing 140471-01.
Bently Nevada 140482-01 is the external-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, external terminations and 3500/42M configuration before replacing 140482-01.
Bently Nevada 149992-01 is the standard 16-channel relay output module used in the 3500/33 machinery-protection relay assembly. It provides the rear-rack switching interface for relay actions configured from the 3500 system's monitoring information. Version check: Confirm standard relay contacts, the minimum load, 149986-01 control module and required energized/de-energized logic before replacing 149992-01.
ProSoft Technology MVI56-DFCM connects a ControlLogix controller to DF1 serial devices through two independently configurable communication ports. Version check: Match the MVI56-DFCM application, DF1 device addressing and port modes; the reduced-data-block MVI56-DFCMR uses a different backplane transfer arrangement.
ProSoft Technology MVI56-DFCMR is a DF1 interface module for ControlLogix applications that use reduced backplane data transfers, including remote racks connected over ControlNet or Ethernet. Version check: Retain the MVI56-DFCMR reduced-block controller data structures and transfer logic; match each port’s DF1 mode, device address and file mapping.
ProSoft Technology MVI56-MCM adds two independent Modbus serial interfaces to a ControlLogix system. Version check: Preserve the MVI56-MCM controller project, register map and serial settings; migration to an enhanced MVI56E variant requires its applicable migration procedure.
ProSoft Technology MVI69-MNETC connects a 1769-based controller application to multiple Modbus TCP/IP server devices. Version check: Match MVI69-MNETC client-only operation, the 1769 controller program and power-supply distance; retain the installed firmware’s supported Ethernet options.
ProSoft Technology PLX31-EIP-MBS4 bridges EtherNet/IP controller data and four independent Modbus serial networks. Version check: Match the four-port PLX31-EIP-MBS4, serial interface modes, I/O connection sizes and installed firmware; retain the matching ProSoft Configuration Builder configuration.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :