ISO 9001:2015 certified industrial automation spare parts supplier

  • IQS450 204-450-000-002 A2-B24-H10-I1 overall view
    Vibro Meter IQS450 204-450-000-002 A2-B24-H10-I1 Proximity Signal Conditioner
    IQS450 204-450-000-002 A2-B24-H10-I1 is the 4 mm current-output IQS450 configuration for a 10 m TQ402/TQ412 proximity measurement chain. Version check: Confirm B24 current output, H10 total cable length, I1 mounting and target-material calibration; B23 voltage units are not interchangeable by appearance.
    Read More
  • GSI127 244-127-000-017 A1-B02 overall view
    Vibro Meter GSI127 244-127-000-017 A1-B02 Galvanic Separation Unit
    GSI127 244-127-000-017 A1-B02 is the standard GSI127 current-to-voltage isolation unit for an IPC or compatible VE210 measurement chain. Version check: Match A1 standard approval and B02 current conversion; IQS current chains require a different transfer option.
    Read More
  • EA402 913-402-000-013 A2-E040-F1-G030 overall view
    Vibro Meter EA402 913-402-000-013 A2-E040-F1-G030 Proximity Probe Extension Cable
    EA402 913-402-000-013 A2-E040-F1-G030 is a 4 m matched extension cable for the TQ402/TQ412–IQS450 chain, with 3 m of flexible stainless-steel hose. Version check: Match the full A2-E040-F1-G030 cable code, probe integral length and IQS450 total-system-length option; do not substitute by cable length alone.
    Read More
  • Yokogawa EC402-50 front connector view
    Yokogawa EC402-50 2-Port ESB Bus Coupler Module
    Yokogawa EC402-50 is a two-port ESB bus coupler for CENTUM N-IO/FIO. Its upper and lower ESB connections link supported field control units to I/O nodes at 128 Mbps. Version check: Match the two-port ESB topology and system release; the 12-nodes-per-port exception applies only to the specified A2FV50 star configuration.
    Read More
  • Yokogawa EC401-50 front connector view
    Yokogawa EC401-50 1-Port ESB Bus Coupler Module
    Yokogawa EC401-50 is a one-port ESB bus coupler for CENTUM N-IO/FIO. It links the field control unit to supported ESB nodes at 128 Mbps and supports single or dual-redundant module arrangements. Version check: For a CP471 system, require EC401 Style S3 or later; also match the one-port ESB topology, node types and redundancy arrangement.
    Read More
  • Yokogawa ALR121-S50 front connector view
    Yokogawa ALR121-S50 2-Port RS-422 RS-485 Communication Module
    Yokogawa ALR121-S50 is a two-port RS-422/RS-485 serial communication module for CENTUM N-IO/FIO systems. It exchanges subsystem data with the FCS using supported functions such as Modbus RTU and FA-M3 communication. Version check: Confirm RS-422/RS-485, the common protocol selected for both ports, baud rate, data mapping and the installed redundancy arrangement.
    Read More
  • Yokogawa ADV551-P60 front connector view
    Yokogawa ADV551-P60 32-Channel 24V DC Digital Output Module
    Yokogawa ADV551-P60 is a 32-channel current-sink transistor output module for CENTUM FIO. It supports status, pulse-width and time-proportioning output patterns with output-status display. Version check: Match -P60, sink-output load and configured point-mode pattern; check paired-channel and redundancy restrictions before replacement.
    Read More
  • Yokogawa ADV151-P60 front connector view
    Yokogawa ADV151-P60 32-Channel 24V DC Digital Input Module
    Yokogawa ADV151-P60 is a 32-channel 24 V DC digital input module for CENTUM FIO. The P version supports pushbutton input, and suffix 6 provides input-status display without explosion protection. Version check: Confirm -P60 pushbutton capability, status display, hardware Style and input polarity; do not substitute an output or SOE-capture version.
    Read More
  • Yokogawa AAP135-S50 front connector view
    Yokogawa AAP135-S50 8-Channel Isolated Pulse Input Module
    Yokogawa AAP135-S50 is an eight-channel isolated pulse input module for CENTUM FIO. It accepts contact, voltage-pulse and current-pulse signals, with frequency limits determined by the selected signal and redundancy configuration. Version check: Match pulse source, frequency, transmitter supply and redundancy mode; dry-contact limits are lower than the 10 kHz electronic-pulse limit.
    Read More
  • Yokogawa AAI841-H00 analog I/O module
    Yokogawa AAI841-H00 8-Input 8-Output HART Analog I/O Module
    Yokogawa AAI841-H00 is a non-isolated FIO module with eight 4–20 mA inputs and eight 4–20 mA outputs. It supports up to eight loops, HART communication and dual-redundant configurations. Version check: Confirm the legacy -H00 code, hardware Style, node and terminal option; HART in an ER-bus remote node requires EB401 Rev. 2 or later.
    Read More
  • Yokogawa AAI543-H50 front connector view
    Yokogawa AAI543-H50 16-Channel HART Analog Output Module
    Yokogawa AAI543-H50 is a 16-channel isolated 4–20 mA output module for CENTUM FIO. It supports HART communication and standard-response switching in a dual-redundant configuration. Version check: Match the -H50 standard switchover response, hardware Style and terminal option; a redundant pair must use the same response class.
    Read More
  • Yokogawa AAI143-H50 front connector view
    Yokogawa AAI143-H50 16-Channel HART Analog Input Module
    Yokogawa AAI143-H50 is a 16-channel isolated 4–20 mA input module for CENTUM FIO. It supports HART communication, per-channel two-wire or four-wire transmitter selection and dual-redundant configurations. Version check: Confirm -H50, hardware Style, two-wire/four-wire channel settings and the existing single or dual terminal adapter.
    Read More
  • Yokogawa AAI135-H50 HART input module
    Yokogawa AAI135-H50 8-Channel HART Analog Input Module
    Yokogawa AAI135-H50 is an eight-channel, channel-isolated 4–20 mA input module for CENTUM FIO systems. It combines process-current acquisition with HART communication and supports dual-redundant module configurations. Version check: Confirm -H50, channel isolation, hardware Style and the installed terminal adapter; -S versions do not provide HART.
    Read More
  • T9882 termination front view
    ICS Triplex T9882 AADvance Dual Analog Output Termination Assembly
    ICS Triplex T9882 is an AADvance dual analog output termination assembly. It provides eight field-output connections and supports two compatible analog output modules for a redundant output arrangement. Version check: Confirm T9882 dual analog-output termination, the matched T9481/T9482 module arrangement, coding pegs and field-loop polarity before replacement.
    Read More
  • T9832 termination front view
    ICS Triplex T9832 AADvance Dual Analog Input Termination Assembly
    ICS Triplex T9832 is an AADvance dual analog input termination assembly. It provides sixteen field-input connections and the termination interface for two compatible analog input modules in a redundant arrangement. Version check: Confirm T9832 dual analog-input termination, matched T9431 or T9432 module types, coding pegs and the existing field-loop fuse arrangement.
    Read More
  • T8461C module front view
    ICS Triplex T8461C Trusted TMR 24/48V DC Digital Output Module
    ICS Triplex T8461C is a coated Trusted TMR digital output module for 24/48 V DC loads. Its forty outputs are arranged in five power groups, with output-state, voltage, current and line-fault diagnostics. Version check: Match T8461C revision, 24/48 V field supply, per-channel load and FTA/cable keying; retain the configured fail-safe output states.
    Read More
  • T8442C module front view
    ICS Triplex T8442C Trusted TMR Speed Monitor Module
    ICS Triplex T8442C is a coated Trusted TMR speed monitor for rotating machinery. It supports three machine groups and provides overspeed and over-acceleration protection using the matching speed-input and shutdown-output termination assemblies. Version check: Confirm T8442C revision, probe type, gear-tooth count, trip settings and the T8846/T8891 termination arrangement before replacement.
    Read More
  • T8431C module front view
    ICS Triplex T8431C Trusted TMR 40-Channel Analog Input Module
    ICS Triplex T8431C is a coated Trusted TMR analog input module for forty process signals. It is typically used with 4–20 mA field loops and reports channel values, line faults and module diagnostics. Version check: Match T8431C hardware, firmware and FTA; for Series C units dated T2108 or later, check product notice 2025-08-002 and the applicable firmware correction.
    Read More
  • T8403 module front view
    ICS Triplex T8403 Trusted TMR 24V DC Digital Input Module
    ICS Triplex T8403 is a Trusted TMR digital input module for forty nominal 24 V DC field inputs. It provides input-state, line-fault and module diagnostic information to the Trusted system. Version check: Match T8403 hardware/software revision, field termination and cable keying; T8403C is the official replacement and still requires system compatibility review.
    Read More
  • T8314C fibre unit front view
    ICS Triplex T8314C Trusted Fibre TX/RX Unit
    ICS Triplex T8314C is a coated Trusted fibre transmitter/receiver unit. It converts copper Expander Bus signals to single-mode fibre for a remote Trusted expansion link of up to 10 km, subject to the link timing requirements. Version check: Confirm T8314C coating, six-unit link arrangement, single-mode SC fibre, cable pairing and the remote Expander Bus timing budget.
    Read More

Request a quote

Have a part number?
Let us check it.

Send the exact model and quantity, plus a nameplate photo or parts list if available.

Dedicated RFQ contact
Sandy Lin Sales & General Manager

Send the complete model and quantity for review.

What happens next

  1. Email confirmation
  2. Requirement review
  3. Written quotation

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message