ISO 9001:2015 certified industrial automation spare parts supplier

Allen-Bradley 1756-HSC ControlLogix High-Speed Counter Module

Allen-Bradley 1756-HSC is a two-channel ControlLogix high-speed counter module for pulse counting, encoder feedback and frequency measurement. It has A/B and Z gate/reset inputs for each counter and four onboard outputs.

Version check: Confirm the hardware series, firmware and Logix module profile. Series A does not provide the later Series C/D digital-filter options.

Download
  • Allen-Bradley 1756-HSC ControlLogix High-Speed Counter Module

    Allen-Bradley 1756-HSC is a ControlLogix high-speed counter module for collecting pulse signals from compatible encoders, proximity switches and other pulse-output devices. It supports count and frequency measurements for applications that need to track events, position or pulse rate independently of the controller's normal scan. Two counter channels process the incoming signals, and four onboard outputs can respond to configured count conditions directly in the module. This local comparison avoids waiting for the controller to evaluate each count condition. Channel and output indicators provide a local view of signal activity, while the selected operating mode determines how the pulses are interpreted.

    Hardware specifications. The 1756-HSC has A, B and Z gate/reset inputs per counter, 5V or 12/24V signal connections, and a count range of 0–16,777,214. Maximum input rates are 1MHz for counter mode, 500kHz for frequency mode and 250kHz for encoder mode. The module occupies one chassis slot and uses a 1756-TBCH or 1756-TBS6H removable terminal block.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer Allen-Bradley
    Catalog number 1756-HSC
    Product type ControlLogix high-speed counter module
    Chassis width 1 slot
    Hardware series in photographs Series A; verify the supplied unit and applicable firmware

    Functional Configuration

    Counter channels 2; A/B and Z gate/reset inputs per counter
    Onboard outputs 4, in 2 groups of 2
    Count range 0–16,777,214
    Removable terminal block 1756-TBCH or 1756-TBS6H

    Performance & Power

    Maximum counter input rate 1MHz
    Maximum frequency-mode input rate 500kHz
    Maximum encoder input rate 250kHz
    Input operating voltage 4.5–5.5V DC or 10–26.4V DC, using the correct input connections
    Backplane current 300mA at 5.1V DC; 3mA at 24V DC
    Output current limits 20mA per point at 5V; 1A per point for 12/24V operation within the rated voltage range

    Environment

    Operating temperature 0–60°C

    Compatibility & Selection Guide

    System and software compatibility. The 1756-HSC belongs to the ControlLogix I/O family. Available functions and configuration profiles depend on both the hardware series and firmware. For a Series A replacement, confirm the firmware major revision and the existing Logix project; later-series digital filters and additional rate modes are not automatic Series A features.

    Wiring & Installation Reference

    Choose the input voltage connection and counter mode before connecting the field device.

    Signal and terminal selection

    Connection Use Check
    A/B inputs Pulse or encoder channels Use the separate 5V or 12/24V connections for the actual signal level.
    Z inputs Gate/reset function Match Z wiring and mode to the intended count operation.
    Output groups Four outputs in two groups Use the external DC supply and commons shown for each output group.

    View terminal diagram (PDF)

    Installation checks

    1. Prepare the chassis

      Verify the installed ControlLogix chassis and power supply, and establish the required safe work condition before handling the module or field wiring.

    2. Key and wire the terminal block

      Use the correct 1756-TBCH or 1756-TBS6H block. Match its mechanical keying to the module and follow the signal-level-specific terminal diagram.

    3. Check shielding and configuration

      Terminate shields according to the grounding instructions, secure the wiring and verify firmware, counter mode and input filter settings before commissioning.

    View RTB keying

    Power and handling precautions

    • Remove power or establish a nonhazardous area before insertion, removal or field connections; energized disconnection can cause an arc.

    • Do not connect 12/24V field signals to the 5V input terminals. Observe electrostatic-discharge precautions and keep counter output operation in a safe state during commissioning.

    Frequently Asked Questions

    What signals can the 1756-HSC count?

    It accepts pulse signals for counting and frequency measurement, and A/B encoder signals for position counting. Each counter also has a Z input for gate/reset functions; select the mode and signal level for the connected device.

    Can the 1756-HSC process a 1MHz quadrature encoder?

    No. The 1MHz limit applies to counter mode; encoder mode is rated to 250kHz. Frequency mode has a separate 500kHz limit.

    Can 5V and 24V devices use the same 1756-HSC input terminals?

    No. Use the input connection designated for 5V or for 12/24V and the corresponding return. Applying the wrong signal voltage to the 5V connection can damage the input.

    Which removable terminal block fits the 1756-HSC?

    Use a 1756-TBCH cage-clamp block or a 1756-TBS6H spring-clamp block. Confirm whether the removable terminal block is included with the offered module.

    Does every 1756-HSC support the same filters and operating modes?

    No. Series A uses a 70Hz debounce filter, while later Series C/D hardware has additional selectable digital filters. Operating modes and configuration options also depend on firmware; verify both series and firmware before replacement.

    Can the 1756-HSC directly switch a 1A load at 5V?

    No. The 5V output rating is 20mA per point. The 1A rating applies to the 12/24V output operating range; also verify the load and external power supply.

    What must be checked before replacing a Series A 1756-HSC?

    Match the hardware series, firmware major revision, operating mode and Logix module profile to the existing project. Exact Match electronic keying requires the configured module identity and revision to match; do not treat a newer series as an unchecked drop-in replacement.

    Can the 1756-HSC capture a count while continuing to count incoming pulses?

    Yes. In Store and Continue mode, the rising edge at input Z copies the present count to Stored Value. Counting continues, and the captured count stays available until the next rising edge at Z.

    Manufacturer Documentation

    1756-HSC Product Reference

    Product photograph, application notes and selected Rockwell Automation pages covering the current module.

    PDF · 7 pages · 118.3 KB · Compiled by EWOLO CONTROL. 1756-TD002U-EN-E U; 1756-UM007E-EN-P E

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Allen-Bradley 1756-HSC

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.