Allen-Bradley 1756-DNB ControlLogix DeviceNet Bridge/Scanner Module

Allen-Bradley 1756-DNB is a ControlLogix DeviceNet bridge/scanner module. It connects a ControlLogix system to DeviceNet field devices and supports 125, 250 or 500kbps network operation.

Version check: Confirm Series E hardware and its minimum firmware 12.x baseline against the controller project and electronic keying. Earlier-series firmware is not interchangeable.

Download
  • Allen-Bradley 1756-DNB ControlLogix DeviceNet Bridge/Scanner Module

    Allen-Bradley 1756-DNB is the DeviceNet bridge/scanner module that connects a ControlLogix system to DeviceNet field equipment. It exchanges input and output data between the controller and network devices, allowing the application to receive field states and issue control commands over the DeviceNet network. The same network also supports device configuration and collection of device information, so the connection serves both control and maintenance tasks. 1756-DNB is intended for a system that specifically uses DeviceNet, including compatible sensors and actuators; its scanner role and device configuration must match the existing network and controller project.

    Hardware specifications. The 1756-DNB supports 125, 250 and 500kbps DeviceNet rates and a maximum of 64 network nodes. Listed trunk-distance limits are 500m, 250m and 100m respectively, subject to network media design. It occupies one 1756 chassis slot, requires 11–25V DC network power and has a USB port for temporary local programming.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer Allen-Bradley
    Catalog number 1756-DNB
    Chassis width 1 slot

    Functional Configuration

    Product function ControlLogix DeviceNet bridge/scanner
    Network DeviceNet
    Data rates 125, 250 or 500kbps
    Maximum network nodes 64 total network nodes
    Listed maximum trunk length 500m at 125kbps; 250m at 250kbps; 100m at 500kbps, with appropriate network media
    USB connection 12Mbps; temporary local programming only, not for hazardous locations
    Network-to-backplane isolation 50V continuous; USB is not isolated
    Photographed hardware series Series E; minimum firmware baseline 12.x

    Performance & Power

    DeviceNet supply 11–25V DC; use the required Class 2/SELV supply arrangement
    DeviceNet current 60mA at 24V DC
    Backplane current 400mA at 5.1V DC; 0mA at 24V DC
    Power dissipation 3.5W

    Environment

    Operating temperature 0–60°C

    Compatibility & Selection Guide

    System and software compatibility. The photographed 1756-DNB is Series E, requiring a minimum firmware baseline of 12.x. Its I/O and configuration data formats are unchanged. Compatibility extends back at least to ControlLogix controller version 12 projects that include the 1756-DNB selection, with the appropriate module revision and Compatible Keying. Confirm the exact controller and software combination before replacement.

    Wiring & Installation Reference

    Verify the Series E module identity, DeviceNet power and network design before connecting the module. These checks do not substitute an installation procedure from another hardware series.

    Signal and terminal selection

    Connection Use Check
    DeviceNet network 11–25V DC network supply Use the required Class 2/SELV supply arrangement and correctly designed DeviceNet media.
    Network connector 5- or 10-pin linear plug Tighten the connector to 0.56–0.79N·m; confirm the connector arrangement for the offered unit.
    USB Temporary local programming Not a permanent connection; never use in a hazardous location.

    View network specifications (PDF)

    Configuration checks

    1. Confirm the system match

      Verify the ControlLogix chassis, available backplane power and the complete Series E hardware identity.

    2. Check DeviceNet design

      Confirm the network supply, baud rate, media, node count and trunk-length limits before connecting field devices.

    3. Verify project compatibility

      Check the Series E minimum firmware 12.x baseline, configured module revision and electronic keying in the controller project before commissioning.

    View firmware compatibility

    Power and handling precautions

    • Do not use the USB port in hazardous locations; USB is not isolated and is intended only for temporary local programming.

    • Use the network power supply and connector limits applicable to the exact module. Do not apply Series C/D-only installation instructions to Series E without a verified applicability statement.

    Frequently Asked Questions

    Is the 1756-DNB an EtherNet/IP module?

    No. Its field-network function is DeviceNet bridge/scanner operation. Select a suitable ControlLogix EtherNet/IP module when the application requires an EtherNet/IP network.

    Which firmware does a Series E 1756-DNB require?

    Series E hardware requires a minimum firmware baseline of 12.x. Its firmware is not compatible with earlier hardware series, so confirm the hardware series before choosing or changing firmware.

    Can a Series E 1756-DNB be used in an older RSLogix 5000 project?

    Its I/O and configuration data formats are unchanged, and compatibility extends back at least to ControlLogix controller version 12 projects that include the 1756-DNB selection. Check the module revision selection, Compatible Keying and exact controller/software combination before replacement.

    How does the 1756-DNB data rate affect DeviceNet distance?

    The listed maximum trunk length is 500m at 125kbps, 250m at 250kbps and 100m at 500kbps. The actual network must also satisfy the applicable media, drop-length and topology requirements.

    Does the 1756-DNB get all its power from the ControlLogix backplane?

    No. It draws 400mA at 5.1V from the backplane and also requires DeviceNet network power. The network-side operating range is 11–25V DC, with a network-side current requirement of 60mA at 24V DC.

    Can the 1756-DNB USB port be left as a permanent plant-network connection?

    No. USB is for temporary local programming only. Do not use the USB port in hazardous locations.

    Does the 1756-DNB support 64 connected slave devices?

    The limit is 64 total DeviceNet network nodes, not 64 additional devices plus the scanner. Include the scanner and every other network node in the network design.

    Which settings are lost if a 1756-DNB is reset to factory defaults?

    A factory reset deletes the scanner's scanlist and stored Automatic Device Replacement recovery data. It also restores the default communication rate, node address and software settings.

    Manufacturer Documentation

    1756-DNB Product Reference

    Product photograph, application notes and selected Rockwell Automation pages covering the current module.

    PDF · 6 pages · 123.1 KB · Compiled by EWOLO CONTROL. 1756-TD003R-EN-E R; 1756-DNB Firmware/Hardware and RSLogix 5000 Compatibility

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Allen-Bradley 1756-DNB

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.