1756-RMC1
Redundancy fiber cable
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier



Chassis-based redundancy module for supported ControlLogix 5560 and 5570 controller systems.
Version check: Match the 1756-RM hardware series and approved redundancy firmware bundle; 1756-RM cannot be paired with 1756-RM2. Series B supports DDR backplane operation in the applicable ControlLogix 5570 configuration.
Lifecycle status: Discontinued
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Allen-Bradley 1756-RM is the redundancy communication module used to link a supported pair of ControlLogix 5560 or 5570 controller chassis. The paired modules provide the fiber-optic connection used by the redundancy system to keep the secondary chassis synchronized with the primary, so the secondary controller can take over when the configured system requires a switchover. 1756-RM performs this redundancy-interface role; the separate controllers execute the application logic. Its purpose is to support controller-system availability, and the chassis pair must use the required matching hardware and compatible firmware rather than treating the module alone as a complete redundancy solution.
Hardware specifications. The module occupies one chassis slot, draws power from the ControlLogix backplane and dissipates 9 W. Its partner fiber connection uses a 1756-RMC1, 1756-RMC3 or 1756-RMC10 cable with a length of 1 m, 3 m or 10 m respectively.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer | Allen-Bradley |
| Complete part number | 1756-RM |
| Product type | ControlLogix redundancy module |
| Module width | 1 chassis slot |
| Module location | Chassis-based, any slot; partner configuration must be matched |
| Approximate weight | 0.29 kg |
Functional Configuration |
|
| Supported controller families | ControlLogix 5560 and 5570 |
| Interconnection cable options | 1756-RMC1 / 1756-RMC3 / 1756-RMC10 |
| Cable lengths | 1 m / 3 m / 10 m |
Performance & Power |
|
| Backplane current at 5.1V DC | 1.2 A |
| Backplane current at 1.2V DC | 4 mA |
| Backplane current at 24V DC | 120 mA |
| Power dissipation | 9.0 W maximum |
| Thermal dissipation | 31 BTU/hr |
Environment |
|
| Operating temperature | 0…60 °C |
| Nonoperating temperature | -40…+85 °C |
| Relative humidity | 5…95%, noncondensing |
System and software compatibility. Partner modules must have the same catalog number and corresponding chassis slots, with all chassis modules using compatible firmware from the same redundancy bundle. Series B supports DDR backplane operation in the applicable ControlLogix 5570 configuration.
The 1756-RM uses the ControlLogix backplane and a dedicated fiber link to its partner redundancy module. It is not a general-purpose Ethernet switch interface.
| Interface | Connection | Check |
|---|---|---|
| Backplane | Install in the supported ControlLogix redundant chassis. | Match the actual hardware series and system configuration. |
| Fiber link | Connect directly to the matching partner redundancy module with an appropriate 1756-RMCx cable. | Match the actual hardware series and system configuration. |
Use one matching module in the corresponding slot of each chassis.
Use a direct end-to-end link between partner fiber ports; do not connect this link through a network switch.
Use matching partner modules in corresponding slots, install compatible engineering software, and verify the hardware and redundancy firmware bundle before assembly.
Install the power supplies, redundancy modules, communication modules and controllers in the required chassis sequence. Connect the partner fiber ports directly and keep both chassis off until all modules are installed.
Update each chassis using the same compatible redundancy firmware bundle. With both chassis initially off, power the intended primary first, confirm PRIM, then power the secondary and verify the chassis designations and synchronization.
Review the safety and environmental requirements for every chassis component before setup.
Do not apply power to either chassis until all modules in both chassis are installed; during firmware updates, power only the chassis being updated.
Use the same compatible redundancy firmware bundle across both chassis, and follow the required primary-then-secondary startup order.
Connect matching redundancy modules directly; do not route the partner fiber link through a network switch.
No. It is the redundancy interface used between a supported pair of controller chassis. Separate controllers execute the application.
It supports ControlLogix 5560 and ControlLogix 5570 redundancy systems. It is not a supported redundancy module for ControlLogix 5580 systems.
No. A 1756-RM module cannot be partnered with a 1756-RM2 module. Follow a validated module-pair migration procedure when changing families.
The specified choices are 1756-RMC1 at 1 m, 1756-RMC3 at 3 m and 1756-RMC10 at 10 m.
It occupies one chassis slot. The partner redundancy modules must be installed in corresponding slots.
The standard 1756-RM operates from 0…60 °C. The RMXT variant has different environmental requirements.
Yes. Series B supports DDR backplane operation in the applicable ControlLogix 5570 configuration. Match the hardware series and firmware to the installed system.
No. The partner fiber ports require a direct end-to-end connection.
Product identification, actual photograph and compatibility notes, followed by selected original manufacturer reference pages.
PDF · 7 pages · 107.4 KB · Compiled by EWOLO CONTROL. 1756-TD001 W / October 2025; 1756-UM015O-EN-P O / July 2026
Preview Product Reference (PDF)Redundancy fiber cable
Redundancy fiber cable
Redundancy fiber cable
ControlLogix chassis
ControlLogix chassis
ControlLogix chassis
ControlLogix chassis
ControlLogix chassis
ControlLogix power supply
ControlLogix power supply
ControlLogix power supply
ControlLogix power supply
Redundant power supply chassis adapter
ControlLogix 5570 controller
ControlLogix 5560 controller
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Bently Nevada 140471-01 is the internal-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, internal terminations and 3500/42M configuration before replacing 140471-01.
Bently Nevada 140482-01 is the external-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, external terminations and 3500/42M configuration before replacing 140482-01.
Bently Nevada 149992-01 is the standard 16-channel relay output module used in the 3500/33 machinery-protection relay assembly. It provides the rear-rack switching interface for relay actions configured from the 3500 system's monitoring information. Version check: Confirm standard relay contacts, the minimum load, 149986-01 control module and required energized/de-energized logic before replacing 149992-01.
ProSoft Technology MVI56-DFCM connects a ControlLogix controller to DF1 serial devices through two independently configurable communication ports. Version check: Match the MVI56-DFCM application, DF1 device addressing and port modes; the reduced-data-block MVI56-DFCMR uses a different backplane transfer arrangement.
ProSoft Technology MVI56-DFCMR is a DF1 interface module for ControlLogix applications that use reduced backplane data transfers, including remote racks connected over ControlNet or Ethernet. Version check: Retain the MVI56-DFCMR reduced-block controller data structures and transfer logic; match each port’s DF1 mode, device address and file mapping.
ProSoft Technology MVI56-MCM adds two independent Modbus serial interfaces to a ControlLogix system. Version check: Preserve the MVI56-MCM controller project, register map and serial settings; migration to an enhanced MVI56E variant requires its applicable migration procedure.
ProSoft Technology MVI69-MNETC connects a 1769-based controller application to multiple Modbus TCP/IP server devices. Version check: Match MVI69-MNETC client-only operation, the 1769 controller program and power-supply distance; retain the installed firmware’s supported Ethernet options.
ProSoft Technology PLX31-EIP-MBS4 bridges EtherNet/IP controller data and four independent Modbus serial networks. Version check: Match the four-port PLX31-EIP-MBS4, serial interface modes, I/O connection sizes and installed firmware; retain the matching ProSoft Configuration Builder configuration.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :