PM856AK01
AC 800M processor unit
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier



ABB PM851AK01 3BSE066485R1 is an AC 800M processor unit with 12 MB memory, a single Ethernet channel and TP830 baseplate connections for an engineered control system.
Version check: Match the full ordering code, system release and required accessories. This model does not provide redundant CPU or High Integrity functionality.
Lifecycle status: Unknown
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
AC 800M processor for process control. ABB PM851AK01 3BSE066485R1 is an AC 800M processor-unit package for executing the configured control application within an ABB control system. The PM851A CPU works with its TP830 baseplate and the selected communication and I/O modules to process signals and coordinate control functions. System 800xA Control Builder or Compact Control Builder provides the engineering environment. This model supports a single controller and one active Ethernet channel; CPU redundancy and High Integrity functionality are not part of the PM851AK01 specification. Its processing capacity and connected I/O requirements therefore define the appropriate application.
Memory and local diagnostics. The exact-model selector lists 24 MHz processing, 12 MB memory and 6.253 MB available for the application from System 800xA 5.1 FP4. The CPU provides a real-time clock, status LEDs, an INIT control and a CompactFlash interface; network and serial connections are brought out through the baseplate.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Manufacturer / ordering code | ABB / PM851AK01 3BSE066485R1 |
| Platform / function | AC 800M / processor unit |
| Dimensions / weight with base | 119 × 186 × 135 mm (W × H × D) / 1100 g |
Functional Configuration |
|
| CPU redundancy / High Integrity | No / No |
| Application RAM | 6.253 MB from System 800xA 5.1 FP4 |
| Typical logic performance | 0.46 ms per 1000 boolean operations |
| Ethernet | One active channel: CN1; 10 Mbit/s |
| Serial interfaces | COM3: RS-232C with modem signals; COM4: isolated service-tool port |
| CEX expansion | Maximum one communication module |
Performance & Power |
|
| Clock frequency | 24 MHz, as listed for the exact ordering code |
| Memory | 12 MB from System 800xA 5.1 FP4 |
| Supply | 24 V DC; permitted range 19.2–30 V DC |
| Typical / maximum current | 180 / 300 mA at 24 V DC |
| ModuleBus capacity | Maximum 24 I/O modules; one electrical and one optical cluster |
Environment |
|
| Operating temperature | 0 to +55 °C |
| Storage / humidity | −40 to +70 °C / 5–95% RH, non-condensing |
| Protection | IP20 |
Engineer for the installed system. Control Builder is used to load the applicable control software and build the application. The AC 800M platform supports stand-alone process control or local control within a larger control network. Match the installed System 800xA release, firmware, libraries and I/O configuration when replacing a unit; do not assume a shared baseplate makes a different CPU interchangeable.
Use ABB AC 800M Controller Hardware 3BSE036351-600 A, single-CPU installation pages 84–92, together with the instructions for the installed system release. The checks below identify interfaces; they do not replace the manufacturer wiring drawings.
| Connection | Purpose | Selection check |
|---|---|---|
| Supply | 24 V DC | Check polarity and 19.2–30 V range |
| CN1 | Control Network Ethernet | Use the single supported channel |
| CN2 | Present on TP830 | Not a redundant Ethernet channel for PM851A |
| COM3 / COM4 | Serial communication / service tool | Use the correct cable and interface configuration |
| CEX / ModuleBus | Communication / I/O expansion | Check module limits and required terminations |
Shut down the controlled process correctly and isolate power before mounting, removing or changing baseplates. Apply electrostatic-discharge precautions.
Mount on the specified horizontal DIN rail and ensure the locking arrangement makes the required grounding contact.
Back up the project, record the system release and confirm the complete CPU/baseplate identity.
Verify communication modules, I/O clusters, power and bus termination against the applicable ABB installation instructions.
Load the approved firmware and application with Control Builder, then verify communications and process interlocks before service.
Do not treat this non-redundant processor as a live standby replacement.
Keep the installation within its temperature and humidity limits, with suitable ventilation.
Confirm the supplied battery, bus terminations, memory card, engineering cable and software entitlement separately.
The INIT control can affect the running application; establish its effect before operating it.
No. The TP830 has CN1 and CN2 sockets, but ABB restricts PM851A to CN1. The presence of the second connector does not enable a redundant Ethernet network.
No. ABB marks both CPU redundancy and High Integrity as No for this exact ordering code. Do not substitute it for a redundant CPU pair or a High Integrity processor.
The exact-model data gives 12 MB total memory and 6.253 MB available for the application from System 800xA 5.1 FP4. Check the installed software release and project memory demand, rather than treating all memory as application space.
ABB limits this processor to one CEX communication module. Its ModuleBus supports one electrical and one optical I/O cluster, with a maximum of 24 I/O modules. Check the selected I/O units and their current requirements.
The required control software and application must be matched to the installed system and loaded through Control Builder. Confirm firmware, project backups and any software entitlement in the quotation; the hardware ordering code alone does not establish the installed software.
ABB defines the K01 package as a PM851A CPU, TP830 baseplate, TB850 CEX-bus terminator, TB807 ModuleBus terminator and 4943013-6 memory-backup battery. No software license is included. This is the manufacturer’s package definition; confirm the actual offered unit’s revision and included items against the quotation and supplied packing list. Photos alone do not verify every accessory.
The AC 800M maintenance cable is TK212A. It is ordered separately from the processor unit.
The standard processor package includes a TB850 CEX-bus terminator and a TB807 ModuleBus terminator.
Product photograph, exact-model specifications, installation notes and selected ABB manufacturer material.
PDF · 3 pages · 113.2 KB · Compiled by EWOLO CONTROL. ABB AC 800M processor selection data.
Preview Product Reference (PDF)AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
AC 800M processor unit
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Yokogawa AAI543-H50 is a 16-channel isolated 4–20 mA output module for CENTUM FIO. It supports HART communication and standard-response switching in a dual-redundant configuration. Version check: Match the -H50 standard switchover response, hardware Style and terminal option; a redundant pair must use the same response class.
Yokogawa AAI841-H00 is a non-isolated FIO module with eight 4–20 mA inputs and eight 4–20 mA outputs. It supports up to eight loops, HART communication and dual-redundant configurations. Version check: Confirm the legacy -H00 code, hardware Style, node and terminal option; HART in an ER-bus remote node requires EB401 Rev. 2 or later.
Yokogawa AAP135-S50 is an eight-channel isolated pulse input module for CENTUM FIO. It accepts contact, voltage-pulse and current-pulse signals, with frequency limits determined by the selected signal and redundancy configuration. Version check: Match pulse source, frequency, transmitter supply and redundancy mode; dry-contact limits are lower than the 10 kHz electronic-pulse limit.
Yokogawa ADV151-P60 is a 32-channel 24 V DC digital input module for CENTUM FIO. The P version supports pushbutton input, and suffix 6 provides input-status display without explosion protection. Version check: Confirm -P60 pushbutton capability, status display, hardware Style and input polarity; do not substitute an output or SOE-capture version.
Yokogawa ADV551-P60 is a 32-channel current-sink transistor output module for CENTUM FIO. It supports status, pulse-width and time-proportioning output patterns with output-status display. Version check: Match -P60, sink-output load and configured point-mode pattern; check paired-channel and redundancy restrictions before replacement.
Yokogawa ALR121-S50 is a two-port RS-422/RS-485 serial communication module for CENTUM N-IO/FIO systems. It exchanges subsystem data with the FCS using supported functions such as Modbus RTU and FA-M3 communication. Version check: Confirm RS-422/RS-485, the common protocol selected for both ports, baud rate, data mapping and the installed redundancy arrangement.
Yokogawa EC401-50 is a one-port ESB bus coupler for CENTUM N-IO/FIO. It links the field control unit to supported ESB nodes at 128 Mbps and supports single or dual-redundant module arrangements. Version check: For a CP471 system, require EC401 Style S3 or later; also match the one-port ESB topology, node types and redundancy arrangement.
Yokogawa EC402-50 is a two-port ESB bus coupler for CENTUM N-IO/FIO. Its upper and lower ESB connections link supported field control units to I/O nodes at 128 Mbps. Version check: Match the two-port ESB topology and system release; the 12-nodes-per-port exception applies only to the specified A2FV50 star configuration.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :