ISO 9001:2015 certified industrial automation spare parts supplier

Emerson KJ3102X1-BE1 12P2703X032 Intrinsically Safe Analog Output Card with HART

Emerson KJ3102X1-BE1 12P2703X032 is an intrinsically safe analog output card with HART for the DeltaV M-series I/O subsystem. It provides eight 4–20 mA output channels for compatible field devices in an engineered intrinsically safe system.

Version check: Confirm the KJ3102X1-BE1 12P2703X032 label, M-series IS carrier, A4 terminal key and standard or loop-disconnect terminal arrangement before ordering.

Download
  • Emerson KJ3102X1-BE1 12P2703X032 Intrinsically Safe Analog Output Card with HART

    Emerson KJ3102X1-BE1 12P2703X032 is an intrinsically safe analog output card with HART for the DeltaV M-series I/O subsystem. It supplies eight 4–20 mA output channels to compatible field devices in an engineered intrinsically safe system, combining analog control output with HART capability. The card is part of DeltaV's native I.S. I/O arrangement, where the field-circuit protection is integrated into the I/O rather than provided by a separate third-party barrier interface. Open-circuit detection helps identify interrupted output loops; hazardous-area suitability remains dependent on the approved complete field circuit.

    Hardware specifications. The KJ3102X1-BE1 12P2703X032 output type has a 1–22 mA full signal range, 12-bit resolution and a maximum load of 650 ohms. The manufacturer specifies a typical 630 mA LocalBus demand at 12 VDC and at least 13 V available to the load at 20 mA.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer Emerson
    Complete identification KJ3102X1-BE1 12P2703X032

    Functional Configuration

    I/O function Intrinsically safe analog output with HART
    Channels 8
    Nominal output signal 4–20 mA
    Full output range 1–22 mA
    Maximum load resistance 650 ohms
    Open-circuit threshold 0.7 mA ±0.2 mA
    Channel isolation No isolation between channels
    Terminal key A4
    Documented terminals KJ4110X1-BA1 or KJ4110X1-BB1

    Performance & Power

    Resolution 12 bits
    LocalBus supply 12 VDC nominal; 630 mA typical per card
    Available load voltage 13 V minimum at 20 mA

    Environment

    Operating temperature −40 to +60 °C
    Relative humidity 5–95%, non-condensing
    Protection IP20

    Compatibility & Selection Guide

    System compatibility. KJ3102X1-BE1 12P2703X032 belongs to the M-series intrinsically safe architecture. Match the A4 terminal key and the documented standard or loop-disconnect terminal block; Emerson expressly excludes M-series I/O cards from S-series controllers and carriers.

    Wiring & Installation Reference

    Use the DeltaV M-series intrinsically safe I/O documentation and the complete 12P1990 hazardous-area installation instructions for the actual system. The linked product reference provides ratings and carrier-layout precautions, not a terminal-by-terminal wiring diagram.

    Output and termination checks

    Signal and load: Eight 4-20 mA outputs with HART; maximum load 650 ohms and at least 13 V available to the load at 20 mA.

    Matching termination: Confirm A4 keying and the KJ4110X1-BA1 standard or KJ4110X1-BB1 loop-disconnect terminal block for the documented IS carrier arrangement.

    View product reference (PDF)

    Intrinsically safe system checks

    1. Check the carrier sequence.

      Install the intrinsically safe carrier section after the standard I/O section; do not add standard I/O carriers after IS carriers.

    2. Complete the hazardous-area assessment.

      Apply the complete 12P1990 instructions, including the connected device and cable parameters. Do not use safety entity limits as normal operating settings.

    View product reference (PDF)

    Power and handling precautions

    • Verify the installed M-series IS carrier, terminal key and approved field circuit before connecting the card.

    • The compact Product Reference does not replace the complete hazardous-area installation instructions. M-series I/O cards are not compatible with S-series controllers and carriers.

    Frequently Asked Questions

    Is KJ3102X1-BE1 12P2703X032 an analog input or output card?

    It is an intrinsically safe analog output card with HART. The similarly named IS analog input card is a different article.

    How many output channels does KJ3102X1-BE1 12P2703X032 provide?

    It provides eight analog output channels with a nominal 4–20 mA signal and HART communication.

    Which terminal arrangement is documented for KJ3102X1-BE1 12P2703X032?

    Use KJ4110X1-BA1 standard IS termination or KJ4110X1-BB1 loop-disconnect termination, with key A4.

    Can KJ3102X1-BE1 12P2703X032 be used with an S-series controller or carrier?

    No. This M-series IS I/O card is not compatible with S-series controllers or carriers.

    What load limit applies to KJ3102X1-BE1 12P2703X032?

    The maximum load resistance is 650 ohms, with at least 13 V available to the load at 20 mA.

    Does KJ3102X1-BE1 12P2703X032 need routine calibration?

    No routine calibration is required; follow the installed system maintenance procedure.

    How much can the analog output of KJ3102X1-BE1 12P2703X032 drift with temperature?

    Output temperature stability is ±0.006% of span per °C.

    Which indicators on KJ3102X1-BE1 12P2703X032 help isolate a channel problem?

    LEDs on top of the card show card power, card errors and the status of its I/O channels.

    Manufacturer Documentation

    KJ3102X1-BE1 12P2703X032 Product Reference

    Product identification, actual photograph and compatibility notes, followed by selected original manufacturer reference pages.

    PDF · 5 pages · 68.3 KB · Compiled by EWOLO CONTROL. M-series Intrinsically Safe I/O July 2023

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Emerson KJ3102X1-BE1 12P2703X032

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.

leave a message

No online payment is requested. Final price and terms are supplied in a written quotation.