Allen-Bradley 1734-AENT is a single-port EtherNet/IP adapter for POINT I/O systems. It connects a POINT I/O assembly to the network through one RJ45 port, supports 10/100 Mbit/s communication and uses a nominal 24 V DC supply.
Version check: Confirm the required hardware series and firmware revision before ordering.
Lifecycle status: Active
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
The Allen-Bradley 1734-AENT is the network interface for a distributed POINT I/O station. Its single RJ45 port links the EtherNet/IP network to the POINTBus backplane, allowing a compatible controller to exchange input and output data with the local I/O modules. It also carries configuration messages. The adapter manages communication, while the selected POINT I/O modules connect to the application's field devices.
System fit and node configuration. Build the station with compatible POINT I/O modules, matching terminal bases and the required power components. The adapter is the station's Ethernet connection; individual I/O modules communicate through the backplane. Configure the network settings and chassis size to match the installed assembly. Rockwell's Series C guidance counts one slot for the adapter plus one for each I/O module: one adapter with four I/O modules uses a chassis size of five. Before replacement, verify the actual hardware series, firmware, controller/software combination and required Add-on Profiles (AOPs).
| Parameter | Specification |
|---|---|
Product Identity |
|
| Brand | Allen-Bradley / Rockwell Automation |
| Catalog number | 1734-AENT |
| Product family | POINT I/O |
Functional Configuration |
|
| Function | EtherNet/IP adapter |
| Network connector | 1 × RJ45 |
| Communication rate | 10/100 Mbit/s; half or full duplex |
| POINTBus output | 5 V DC, 1.0 A maximum |
| I/O expansion | Up to 63 POINT I/O modules, subject to power and connection limits |
Performance & Power |
|
| Nominal supply | 24 V DC |
| Supply voltage range | 10–28.8 V DC |
Environment |
|
| Mounting / enclosure | DIN rail / open-style |
| Operating temperature | −20 to +55 °C |
Expansion and power planning. A station can accommodate up to 63 I/O modules, subject to module compatibility, connection limits and the POINTBus current budget. The 1734-AENT supplies up to 1.0 A of backplane current; the number of modules it can power directly depends on their combined demand. Where more backplane power is needed, 1734-EP24DC or 1734-EPAC expansion supplies support additional module groups while maintaining POINTBus data continuity. Size the supply for each group and recheck the station configuration when adding modules.
The reference below follows Rockwell's instructions for 1734-AENT Series C. Check the unit's series and use the matching manual before installation.
| No. | Marking | Connection |
|---|---|---|
| 0, 1 | NC | Leave unconnected |
| 2, 3 | Chas GND | Chassis ground |
| 4, 5 | C | DC common |
| 6, 7 | V | DC supply |
DC supply: 24 V DC nominal; 10–28.8 V DC input range.
Terminal screw torque: 0.8 N·m.
EtherNet/IP: connect through the RJ45 port using the cable type specified in the matching manual.
With power isolated, use a grounded 35 × 7.5 mm steel rail with zinc plating and chromate passivation. Fasten it approximately every 200 mm.
Place the adapter above the rail with its locking mechanism horizontal. Press down until it locks onto the rail.
Leave 25.4 mm (1 in.) between adjacent equipment for ventilation. Fit the safety end cap to the final mounting base.
Use a SELV/PELV-compliant source. Never apply 120/240 V AC to the adapter's DC supply input. Limit each terminal to two conductors.
Isolate power before removing or replacing the adapter. For Ethernet or removable-terminal-block connections, disconnect power or establish that the location is nonhazardous before unplugging or reconnecting; follow the manual's complete precautions.
No. Check the product label and firmware information for the specific unit. Photos are for identification; the series and firmware supplied must be confirmed before purchase.
No. 1734-AENT has one RJ45 port. Do not substitute a different catalog number without checking the network configuration and compatibility.
Use Rockwell Automation’s Product Compatibility and Download Center (PCDC) to verify the planned POINT I/O module and adapter combination. Before replacement, also confirm the required hardware series, firmware revision and controller/software compatibility.
Send the complete catalog number, quantity and delivery destination. For replacement enquiries, include a clear nameplate photo and any required hardware series or firmware revision.
The nominal supply is 24 V DC, with a specified input range of 10–28.8 V DC. Follow the manufacturer’s installation instructions when checking supply requirements and wiring.
Up to 63 POINT I/O modules, subject to connection limits and the POINTBus power budget. The adapter provides up to 1.0 A of backplane current; expansion power supplies may be required.
The procedure depends on the hardware series. For Series C, Rockwell documents thumbwheel address selection, DHCP and saved network settings. When using the Rockwell BOOTP/DHCP utility with Series C, use DHCP. Confirm the unit’s series and follow its matching manual before configuration.
The indicators report module operation, network activity and status, POINTBus status, system power and field power. For example, a solid red Network Status indicator means a duplicate IP address was detected. Consult the official indicator table for the meaning of each colour and flashing pattern.
Mount the POINT I/O system on a 35 × 7.5 mm DIN rail, following Rockwell’s grounding and clearance instructions. The 1734-AENT is open-type equipment for indoor use and must be installed in a suitable protective enclosure.
Rockwell specifies an operating temperature range of −20 to +55 °C (−4 to +131 °F), with a maximum surrounding-air temperature of 55 °C. Check the temperature inside the enclosure and follow the installation requirements for the actual application.
Product photographs, an expanded overview and system configuration notes, together with selected Rockwell Automation pages covering DIN rail mounting, terminal wiring and technical specifications.
PDF · 6 pages · 105.7 KB · Compiled by EWOLO CONTROL. Manufacturer extracts: 1734-IN042J-EN-P, June 2026, Series C.
Preview Product Reference (PDF)POINT I/O SSI absolute encoder interface module
POINT I/O 2-channel analog current output module
POINT I/O AC expansion power module
POINT I/O 2-channel analog current input module
POINT I/O 8-channel analog current input module
POINT I/O 4-channel IO-Link master module
POINT I/O very high-speed counter module
POINT I/O 2-channel analog voltage output module
POINT I/O 4-channel analog current output module
POINT I/O 2-channel sinking output module
POINT I/O 8-channel sinking output module
POINT I/O 2-point relay output module
POINT I/O 8-point configurable I/O module
POINT I/O 8-point configurable I/O module with DeviceLogix
POINT I/O dual-port EtherNet/IP adapter
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
Allen-Bradley 1734-AENT is a single-port EtherNet/IP adapter for POINT I/O systems. It connects a POINT I/O assembly to the network through one RJ45 port, supports 10/100 Mbit/s communication and uses a nominal 24 V DC supply. Version check: Confirm the required hardware series and firmware revision before ordering.
Bently Nevada 140471-01 is the internal-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, internal terminations and 3500/42M configuration before replacing 140471-01.
Bently Nevada 140482-01 is the external-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, external terminations and 3500/42M configuration before replacing 140482-01.
Bently Nevada 149992-01 is the standard 16-channel relay output module used in the 3500/33 machinery-protection relay assembly. It provides the rear-rack switching interface for relay actions configured from the 3500 system's monitoring information. Version check: Confirm standard relay contacts, the minimum load, 149986-01 control module and required energized/de-energized logic before replacing 149992-01.
ProSoft Technology MVI56-DFCM connects a ControlLogix controller to DF1 serial devices through two independently configurable communication ports. Version check: Match the MVI56-DFCM application, DF1 device addressing and port modes; the reduced-data-block MVI56-DFCMR uses a different backplane transfer arrangement.
ProSoft Technology MVI56-DFCMR is a DF1 interface module for ControlLogix applications that use reduced backplane data transfers, including remote racks connected over ControlNet or Ethernet. Version check: Retain the MVI56-DFCMR reduced-block controller data structures and transfer logic; match each port’s DF1 mode, device address and file mapping.
ProSoft Technology MVI56-MCM adds two independent Modbus serial interfaces to a ControlLogix system. Version check: Preserve the MVI56-MCM controller project, register map and serial settings; migration to an enhanced MVI56E variant requires its applicable migration procedure.
ProSoft Technology MVI69-MNETC connects a 1769-based controller application to multiple Modbus TCP/IP server devices. Version check: Match MVI69-MNETC client-only operation, the 1769 controller program and power-supply distance; retain the installed firmware’s supported Ethernet options.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :