106M1081-01
3500/15 universal AC power input module
No online payment is requested. Final price and terms are supplied in a written quotation.
ISO 9001:2015 certified industrial automation spare parts supplier





Bently Nevada 129478-01 is the legacy high-voltage DC power input module for the 3500/15 system. The documented legacy high-voltage DC input range is 88 to 140 Vdc.
Version check: Confirm 129478-01 is the required legacy high-voltage DC PIM and match the installed supply/PIM generation before ordering.
Lifecycle status: Unknown
Product image is representative; revision or series may vary.
Contact us to request a specific version.
12-month return-to-base cover.
Eligibility per quote.
DHL, FedEx or UPS.
Or use an agreed carrier account.
Bank transfer before dispatch,
unless agreed in writing.
Bently Nevada 129478-01 is the legacy high-voltage DC Power Input Module for the 3500/15 rack power arrangement. It receives the incoming DC supply at the rear of the rack and works with the associated 129486-01 power-supply module, which converts that input into voltages used by the monitoring modules. The legacy high-voltage DC option is specified for 88–140 VDC input. Selecting this PIM preserves the input-side role and generation of the existing power assembly; later DC supply and PIM designs are not interchangeable with the legacy pair.
Hardware specifications. The applicable legacy datasheet specifies 88 to 140 Vdc for the high-voltage DC option. The PIM envelope is 120.7 x 25.4 x 114.3 mm (H x W x D), and the published operating range is -30 to +65 degrees C. Its dimensions and role must be distinguished from the wider and deeper front power-supply module.
| Parameter | Specification |
|---|---|
Product Identity |
|
| Part number | 129478-01 |
| Component | Legacy high-voltage DC Power Input Module |
| PIM dimensions (H x W x D) | 120.7 x 25.4 x 114.3 mm |
Functional Configuration |
|
| Family | 3500/15 |
| PIM rack position | Special half-height module behind the associated supply |
| Generation requirement | Legacy and newer DC supply/PIM generations are not compatible |
Performance & Power |
|
| Applicable legacy DC input | 88 to 140 Vdc |
Environment |
|
| Operating temperature | -30 to +65 degrees C |
| Storage temperature | -40 to +85 degrees C |
| Humidity | 95%, non-condensing |
System compatibility. The 3500/15 architecture supports a primary supply and an optional backup in a 3500 rack. For 129478-01, the essential compatibility check is the legacy DC supply/PIM generation: the current manufacturer datasheet explicitly states that the newer high- and low-voltage DC supplies and PIMs are not compatible with legacy DC components. A common voltage range does not establish interchangeability.
Use the current manufacturer reference to check the exact module, its documented system position and applicable termination arrangement.
Match 129478-01 and verify the associated legacy high-voltage DC supply.
Confirm that the source is within the applicable 88-140 Vdc range before proceeding with the system service procedure.
129478-01 belongs to the legacy 88-140 Vdc arrangement. Do not select an AC, low-voltage DC or newer-generation PIM on the basis of a similar appearance.
Keep legacy supply and input-module generation requirements intact.
The legacy datasheet identifies power-supply operations and maintenance manual 129767-01; terminal-level procedures are not reproduced in this datasheet extract.
The PIM occupies the special half-height position behind the associated power supply. The official layout identifies the high-voltage DC PIM separately from other input variants.
The newer high- and low-voltage DC power supplies and PIMs are not compatible with the legacy DC supplies and PIMs. Confirm the generation of both parts.
The manufacturer permits power-supply removal without interrupting the rack only when the other supply is installed. This statement is not permission to remove the PIM or connect live input wiring.
129478-01 is the legacy high-voltage DC input module; 129486-01 is the legacy high-voltage DC power supply. Their roles and physical dimensions differ. Identify the required rear input component or front supply before ordering.
No such interchangeability is supported. The current manufacturer datasheet explicitly says the newer high- and low-voltage DC supplies and PIMs are not compatible with their legacy counterparts. Match the complete DC power generation.
129478-01 is identified as the high-voltage DC PIM. The applicable legacy high-voltage DC option is 88 to 140 Vdc. The low-voltage DC and AC options use separately identified components.
The legacy datasheet states that an overvoltage causes the fuse on the PIM to open, while undervoltage does not harm the supply or PIM. This does not replace the specified input range or the need to diagnose the cause before service.
The manufacturer describes continued rack operation when a power-supply module is removed or inserted while a second supply is installed. That statement concerns the supply module; it does not authorize disconnecting energized PIM field wiring. Use the applicable service procedure for the input assembly.
The replacement fuse is 01720045 for the legacy high-voltage DC PIM.
The legacy high-voltage DC power option has a specified full-rack input current of 2.5 A maximum.
The legacy power-input module weighs 0.34 kg (0.75 lb).
Product photograph, identification and technical reference, with selected manufacturer pages covering the documented component and its system requirements.
PDF · 4 pages · 123.1 KB · Compiled by EWOLO CONTROL. Manufacturer references: 141530-01 Rev. C (07/09); 141530 Rev. P.
Preview Product Reference (PDF)3500/15 universal AC power input module
3500/15 universal AC power supply module
3500/15 legacy high-voltage DC power supply module
3500/15 legacy low-voltage DC power supply module
3500/15 legacy low-voltage DC power input module
3500/15 high-voltage DC power supply module
3500/15 high-voltage DC power input module
3500/15 low-voltage DC power supply module
3500/15 low-voltage DC power input module
3500/40M Proximitor I/O, internal terminations
3500/40M Proximitor I/O, external terminations
3500/40M Proximitor I/O with internal barriers
3500/40M Proximitor monitor
3500/25 Keyphasor I/O, internal terminations
3500/25 Keyphasor I/O, external terminations
EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.
We source DCS, PLC and TSI spares for maintenance and replacement.
Pay by bank transfer before dispatch, unless agreed otherwise in writing.
Model, quantity and visible condition are checked against your order.
Packaging is selected for the product and agreed shipping method.
DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.
Commercial invoice and packing list supplied. Agree extra documents before ordering.
Eligible items: 12-month return-to-base warranty from dispatch, per quotation.
Send fault details and photos. Returns need prior written approval.
REQUEST A QUOTE
Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.
Request a Quote →Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.
No online payment is requested. Final price and terms are supplied in a written quotation.
EA402 913-402-000-013 A2-E040-F1-G030 is a 4 m matched extension cable for the TQ402/TQ412–IQS450 chain, with 3 m of flexible stainless-steel hose. Version check: Match the full A2-E040-F1-G030 cable code, probe integral length and IQS450 total-system-length option; do not substitute by cable length alone.
Bently Nevada 133819-01 is the internal-termination, non-isolated RTD/TC I/O module for the 3500/60 temperature-monitoring system. It forms the rear-rack sensor interface for a six-channel temperature monitor used to evaluate machinery temperatures and compare them with user-programmed alarm limits. Version check: Confirm the 3500/60 monitor, non-isolated RTD/TC input and internal termination arrangement before replacing 133819-01.
Bently Nevada 133827-01 is the external-termination, non-isolated RTD/TC I/O module for the 3500/60 temperature-monitoring system. It forms the rear-rack sensor interface for a six-channel temperature monitor used to evaluate machinery temperatures and compare them with user-programmed alarm limits. Version check: Confirm the 3500/60 monitor, non-isolated RTD/TC input and external termination arrangement before replacing 133827-01.
Bently Nevada 135489-01 is the Prox/Accel I/O module with internal barriers and internal terminations for the 3500/42M machinery-protection monitor. It combines the rear-rack field interface with the internal-barrier option required by a correctly engineered intrinsically safe transducer system. Version check: Confirm the 3500/42M monitor, four Prox/Accel channels and approved internal-barrier circuit before replacing 135489-01.
Bently Nevada 135489-04 is the Proximitor I/O module with internal barriers and internal terminations for the 3500/40M machinery-protection monitor. It combines the rear-rack field interface with the internal-barrier option required by a correctly engineered intrinsically safe transducer system. Version check: Confirm the 3500/40M monitor, Proximitor configuration and approved internal-barrier circuit before replacing 135489-04.
Bently Nevada 138708-01 is the internal-termination Shaft Absolute I/O module for the 3500/42M machinery-protection monitor. It provides the dedicated rear-rack interface for an appropriately configured shaft-absolute measurement assembly, with supported proximity/acceleration, Velomitor or Seismoprobe transducers. Version check: Confirm the 3500/42M M-version monitor, shaft-absolute sensor arrangement and required firmware/software revisions before replacing 138708-01.
Bently Nevada 140471-01 is the internal-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, internal terminations and 3500/42M configuration before replacing 140471-01.
Bently Nevada 140482-01 is the external-termination Prox/Velom I/O module for the 3500/42M machinery-protection monitor. It provides the rear-rack interface for supported Prox/Accel, Velomitor and High Temperature Velocity Sensor (HTVS) applications. Version check: Confirm the Prox/Accel, Velomitor or HTVS transducers, external terminations and 3500/42M configuration before replacing 140482-01.
No online payment is requested. Final price and terms are supplied in a written quotation.
Scan to Wechat :
Scan to WhatsApp :