ISO 9001:2015 certified industrial automation spare parts supplier

Bently Nevada 126615-01 Proximitor I/O Module with External Terminations

Bently Nevada 126615-01 is the external-termination Proximitor I/O module for a 3500/40M machinery-protection monitor. It provides the rear-rack field interface for proximity-transducer signals, with field connections routed through separately selected external termination blocks and cables.

Version check: Confirm the 3500/40M monitor, external termination block style and 129525 cable configuration before replacing 126615-01.

Download
  • Bently Nevada 126615-01 Proximitor I/O Module with External Terminations

    Bently Nevada 126615-01 is the external-termination Proximitor I/O module for the 3500/40M machinery-protection monitor. It provides the rear-rack interface between proximity transducers and the monitor, with field signals routed through external termination blocks and cables. In the 3500/40M assembly, these signals provide radial vibration, eccentricity, thrust position and differential expansion measurements. The monitor continuously compares measured values with programmed alarm setpoints and supplies machinery-condition information to operations and maintenance personnel.

    Hardware specifications. The 126615-01 occupies one full-height rear I/O slot and measures 241.3 × 24.4 × 99.1 mm. The 3500/40M accepts up to four proximity-transducer signals. Standard I/O input impedance is 10 kΩ, and the transducer supply is −24 Vdc. This non-barrier I/O version has an operating range of −30 to +65 °C.

    Technical Specifications

    Parameter Specification

    Product Identity

    Manufacturer Bently Nevada
    Complete part number 126615-01
    Compatible monitor 3500/40M; monitor spare 176449-01
    I/O dimensions 241.3 × 24.4 × 99.1 mm (H × W × D)
    Rack space One full-height rear I/O slot

    Functional Configuration

    Termination External; blocks and cables ordered separately
    Signal interface Up to four proximity-transducer channels in the monitor assembly

    Performance & Power

    Standard I/O input impedance 10 kΩ
    Transducer power −24 Vdc

    Environment

    Operating temperature −30 to +65 °C
    Storage temperature −40 to +85 °C

    Compatibility & Selection Guide

    System compatibility. 126615-01 operates with the four-channel 3500/40M and 3500 Rack Configuration Software. Channels 1/2 and 3/4 form two programmable pairs, allowing two measurement functions in one monitor. The general minimum software versions are 3500/01 v2.50, 3500/02 v2.20 and 3500/03 v1.21. REBAM operation uses 3500/40M firmware Rev. 2.1 or later, 3500/01 v3.30, 3500/02 v2.40, 3500/03 v1.40 and DM2000 v3.40 or later.

    Wiring & Installation Reference

    Connection and replacement reference for 126615-01. Use the applicable monitor instructions and actual module markings.

    Field connections

    Use the external-transducer connector with the matched external termination block and cable.

    125808-01 provides Euro-style connectors; 128015-01 provides terminal-strip connectors.

    View connection reference (PDF)

    Installation and replacement

    1. Confirm the assembly

      Match 126615-01 to the 3500/40M and record the existing external block and cable.

    2. Check rack allocation

      Allocate one full-height rear I/O slot aligned with the associated monitor.

    3. Verify connections

      Follow the 3500/40M user guide and actual terminal markings before commissioning.

    View module reference

    Power and handling precautions

    • Use the applicable 3500 monitor user guide and the actual module markings for terminal assignments and service procedures.

    • Match the complete I/O part number, monitor revision and transducer configuration before reconnecting field circuits.

    Frequently Asked Questions

    Which assembled cable suits a 25 ft run from 126615-01 to its external termination block?

    Use 129525-0025-02 for the 25 ft (7.6 m) transducer-to-external-termination cable. In this cable code, 0025 selects the length and 02 selects the assembled version; suffix 01 selects an unassembled cable.

    Where can an analyzer obtain raw transducer signals when 126615-01 is used?

    The associated 3500/40M provides one buffered coaxial connector per channel on its front panel. Each output has 550 Ω impedance and short-circuit protection, providing an access point for the channel signal during diagnostic measurements.

    Which radial-vibration filter should be selected with 126615-01 for measurements extending down to 1 Hz?

    Select the 3500/40M radial-vibration Direct filter range of 1–600 Hz. The alternative range is 4–4,000 Hz. The Gap filter has a separate −3 dB cutoff at 0.09 Hz.

    Over what machine-speed range are 1X and 2X radial-vibration values valid with 126615-01?

    With the 3500/40M configured for radial vibration, 1X and 2X vector values are valid from 60 to 60,000 cpm. The same speed range applies to Not 1X and Smax parameters.

    Can a 3500/40M using 126615-01 alarm separately on Direct, 1X and 2X vibration?

    Yes. Alert setpoints can be assigned to every active measured value, including Direct, 1X amplitude and 2X amplitude. Danger setpoints can be assigned to any two active values per channel, so the trip parameters are selected separately from the wider set of Alert parameters.

    What alarm delays can be programmed for vibration and position channels using 126615-01?

    For radial vibration, thrust position, differential expansion and eccentricity on the 3500/40M, Alert delay is 1–60 seconds in 1-second steps. Danger delay is either 0.1 second or 1–60 seconds in 0.5-second steps.

    Which probe sensitivities can be configured for radial vibration and thrust with 126615-01?

    The 3500/40M supports 3.94 mV/μm (100 mV/mil) and 7.87 mV/μm (200 mV/mil) for radial-vibration and thrust-position inputs.

    What happens to REBAM filters if the shaft-speed signal has an error in a system using 126615-01?

    The 3500/40M uses the nominal filter set during a shaft-speed error. With a valid speed signal, it changes to the lower filter set at 90% or less of nominal speed and returns at 95% or more; it changes to the higher set at 110% or more and returns at 105% or less.

    Manufacturer Documentation

    126615-01 Product Reference

    Product photographs, model-specific specifications and selected original manufacturer pages covering the applicable I/O configuration and module reference.

    PDF · 5 pages · 110.2 KB · Compiled by EWOLO CONTROL. 141535 Rev. R

    Preview Product Reference (PDF)

    Order & Service Support

    EWOLO CONTROL is an independent supplier of industrial automation spare parts. See About Us for our company background and Company Qualifications for the published ISO 9001:2015 certificate and supplier assessment records.

    01

    Discontinued & Hard-to-Find Parts

    We source DCS, PLC and TSI spares for maintenance and replacement.

    02

    Order & Payment Confirmation

    Pay by bank transfer before dispatch, unless agreed otherwise in writing.

    03

    Pre-Dispatch Verification

    Model, quantity and visible condition are checked against your order.

    04

    Protective Packaging

    Packaging is selected for the product and agreed shipping method.

    05

    Global Shipping & Tracking

    DHL, FedEx, UPS or an agreed carrier. Tracking follows collection.

    06

    Order Documentation

    Commercial invoice and packing list supplied. Agree extra documents before ordering.

    07

    12-Month Warranty

    Eligible items: 12-month return-to-base warranty from dispatch, per quotation.

    08

    After-Sales Support

    Send fault details and photos. Returns need prior written approval.

    REQUEST A QUOTE

    Bently Nevada 126615-01

    Include the part number, required quantity and destination in your enquiry. Add the required hardware series or firmware revision, if applicable.

    Request a Quote   →

    Confirm the offered unit's condition, quantity, included accessories and dispatch time in the quotation.

Send your requirement

Fields marked * are required.

No online payment is requested. Final price and terms are supplied in a written quotation.